The DOI matches its Crossref record.
Use of protein-based standards in automated colorimetric determinations of fructosamine in serum.
Abstract
We have developed an automated colorimetric assay for glycated serum proteins (or fructosamines), measuring the reducing activity of serum in alkaline solution (pH 10.35) at 37 degrees C. The calibrants were prepared from a synthetic fructosamine (1-deoxy-1-morpholinofructose), although secondary standards of glycated bovine albumin were more robust in routine application. Interference was appreciable only with icteric specimens (bilirubin greater than 60 mumol/L), and between-batch imprecision (CV) was less than 2%. The range of fructosamine concentrations measured in 502 healthy (nondiabetic) blood donors was 1.87-2.87 mmol/L. There were no significant (p greater than 0.05) age- or sex-related differences in this population sample. Fructosamine accurately reflected blood glucose control as evidenced by the significant correlation with glucose concentrations in fasting plasma (r = 0.82, p less than 0.001) and with glycated hemoglobin (HbA1c) (r = 0.87, p less than 0.01) in 115 patients with type 2 (non-insulin-dependent) diabetes mellitus. The test is simple and rapid to perform (75 samples per hour) and provides an alternative to HbA1c determinations for monitoring blood glucose control and assessing the effects of changes in diabetes management.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Clinical Relevance of Biomarkers of Oxidative Stress
Frijhoff, J., Winyard, P. G., Zarkovic, N., Davies, S. S., Stocker, R., Cheng, D., Knight, A. R., Taylor, E. L., Oettrich, J., Ruskovska, T., et al. (2015) · Antioxidants & Redox Signaling · doi:10.1089/ars.2015.6317 · Cited by 909
Fructosamine: structure, analysis, and clinical usefulness.
Armbruster, D. A. (1987) · Clinical Chemistry · doi:10.1093/clinchem/33.12.2153 · Cited by 437
The glycation of albumin: Structural and functional impacts
Rondeau, P., & Bourdon, E. (2011) · Biochimie · doi:10.1016/j.biochi.2010.12.003 · Cited by 433
Overexpression of Fibronectin Induced by Diabetes or High Glucose: Phenomenon With a Memory
Roy, S., Sala, R., Cagliero, E., & Lorenzi, M. (1990) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.87.1.404 · Cited by 409
Macdonald, I. A., Scott, A. R., Bowman, C. A., & Jeffcoate, W. J. (1990) · Diabetic Medicine · doi:10.1111/j.1464-5491.1990.tb01309.x · Cited by 26
Metadata
- Authors
- Baker, J. R., Metcalf, P. A., Johnson, R. N., Newman, D., & Rietz, P.
- Venue
- Clinical Chemistry
- Publisher
- Oxford University Press (OUP)
- Published
- 1985-09-01
- Volume
- 31
- Issue
- 9
- Pages
- 1550-1554
- ISSN
- 0009-9147 (ISSN-L)
- 1530-8561
- OpenAlex
- W1836902952
- Cited by
- 166
- References
- 0
- FWCI
- 9.20
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Use of protein-based standards in automated colorimetric determinations of fructosamine in serum. https://app.cochat.ai/papers/10.1093/clinchem/31.9.1550
- The paper
- Baker, J. R., Metcalf, P. A., Johnson, R. N., Newman, D., & Rietz, P. (1985). Use of protein-based standards in automated colorimetric determinations of fructosamine in serum. Clinical Chemistry. https://doi.org/10.1093/clinchem/31.9.1550
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.