Determination of retinyl esters and retinol in serum or plasma by normal-phase liquid chromatography: method and applications.
The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
Retinol and retinyl esters are measured in serum or plasma samples by gradient, normal-phase, adsorption "high-performance" liquid chromatography, with ultraviolet detection at 325 nm. The four major circulating retinyl esters in humans (esters of palmitate, stearate, oleate, and linoleate) are coeluted as a single peak. Retinyl acetate is included as an internal standard, to correct for variable recovery. Retinol values so measured correlated well (r = 0.88) with those by a widely used reversed-phase chromatographic technique (Clin Chem 1983;29:708-12). The mean retinol concentration was 570 (SEM 17) micrograms/L and the mean for retinyl esters was 33 (SEM 4) micrograms/L as determined in samples from 88 fasting young adults. Concentrations of retinol in plasma as low as 50 micrograms/L can be detected in 100-microL samples, as can 10 micrograms of retinyl esters per liter. Using this method, we measured absorption of low doses of vitamin A, which may provide a more physiological approach to assessment of fat malabsorption. Additionally, the procedure proved useful for quickly screening for vitamin A toxicity. Major advantages include small sample size, direct injection of the extract ed sample without evaporation, rapid elution pattern, co-elution of major retinyl esters as a single peak, and low limit of detection.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
A RAPID METHOD OF TOTAL LIPID EXTRACTION AND PURIFICATION
Bligh, E. G., & Dyer, W. J. (1959) · Canadian Journal of Biochemistry and Physiology · doi:10.1139/o59-099 · Cited by 54,751
Cited by
The acute and chronic toxic effects of vitamin A
Penniston, K. L., & Tanumihardjo, S. A. (2006) · The American Journal of Clinical Nutrition · doi:10.1093/ajcn/83.2.191 · Cited by 577
Biomarkers of Nutrition for Development (BOND)-Vitamin A Review
Tanumihardjo, S. A., Russell, R. M., Stephensen, C. B., Gannon, B. M., Craft, N. E., Haskell, M. J., Lietz, G., Schulze, K., & Raiten, D. J. (2016) · The Journal of Nutrition · doi:10.3945/jn.115.229708 · Cited by 451
Self-citationCohn, J. S., Johnson, E. J., Millar, J. S., Cohn, S. D., Milne, R. W., Marcel, Y. L., Russell, R. M., & Schaefer, E. J. (1993) · Journal of Lipid Research · doi:10.1016/s0022-2275(20)35345-1 · Cited by 248
Self-citationModerate fish oil intake improves lipemic response to a standard fat meal: A study in 25 healthy men
Brown, A. J., & Roberts, D. C. (1991) · Arteriosclerosis and Thrombosis: A Journal of Vascular Biology · doi:10.1161/01.atv.11.3.457 · Cited by 59
Metadata
- Authors
- Bankson, D. D., Russell, R. M., & Sadowski, J. A.
- Venue
- Clinical Chemistry
- Publisher
- Oxford University Press (OUP)
- Published
- 1986-01-01
- Volume
- 32
- Issue
- 1
- Pages
- 35-40
- ISSN
- 0009-9147 (ISSN-L)
- 1530-8561
- OpenAlex
- W1923757058
- Cited by
- 71
- References
- 1
- FWCI
- 4.72
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.