CoChat

Use of a new sample-collection device (Macroduct) in anion analysis of human sweat.

Cole, D E, Boucher, M J · 1986 · Clinical Chemistry
Cited by 25

The DOI matches its Crossref record.

Abstract

We compared concentrations of chloride and sulfate in sweat obtained by use of the Macroduct capillary-coil collection device with results obtained by the conventional absorbent filter pad technique. Samples obtained with the device weighed less than those obtained conventionally, but sweat chloride concentrations were not significantly different. To assess analysis of trace anions, we used inorganic sulfate as a prototype. Background contamination, a problem with the filter pads, was negligible with the Macroduct collector. However, with the Macroduct device, sulfate concentrations were nominally higher than with the conventional pads (105 +/- 6 vs 88 +/- 5 mumol/L) and showed no dependence of sulfate concentration on sweat rate. Subtraction of the significant "background" SO4 concentration obtained with blanks (i.e., unused filter pads) is a likely source of error in the conventional method. We consider the Macroduct device useful for study of trace constituents of human sweat.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1093/clinchem/32.7.1375

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 25

Metadata

Authors
Cole, D. E., & Boucher, M. J.
Venue
Clinical Chemistry
Published
1986-07-01
Volume
32
Issue
7
Pages
1375-1378
ISSN
  • 0009-9147 (ISSN-L)
  • 1530-8561
OpenAlex
W1957349807
Cited by
25
References
0
FWCI
0.00
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Use of a new sample-collection device (Macroduct) in anion analysis of human sweat. https://app.cochat.ai/papers/10.1093/clinchem/32.7.1375
The paper
Cole, D. E., & Boucher, M. J. (1986). Use of a new sample-collection device (Macroduct) in anion analysis of human sweat. Clinical Chemistry. https://doi.org/10.1093/clinchem/32.7.1375

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.