Wearable electrochemical alcohol biosensors
Open accessAbstract
The rapid development of wearable sensing platforms in recent years has led to an array of viable monitoring applications for various target analytes. As a significant biomarker with high impact in diverse areas, the reliable on-body detection and continuous monitoring of alcohol has become a focus of many such systems. Currently, several commercial sensing platforms are available that are capable of transdermal monitoring of alcohol consumption using insensible sweat. Drawbacks of existing alcohol sensing platforms that apply this sensing strategy have led to efforts in developing wearable biosensors capable of real-time alcohol detection in sampled biofluids such as sensible sweat and skin interstitial fluid. This review discusses the current trends in wearable electrochemical alcohol biosensing and highlights recent advances in such systems toward continuous, real-time monitoring of alcohol consumption. Our perspective on this important field is given with an outlook on the future of wearable electrochemical alcohol biosensors.
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
ISF composition leads to reliable correlations between blood and ISF concentrations of many analytes, including electrolytes, metabolites, and proteins.
“This function, and the associated ISF composition, lead to reliable correlations between the blood and ISF concentrations of many analytes, including electrolytes (e.g., sodium, phosphate, magnesium, potassium or calcium), metabolites (e.g., glucose, alcohol, lactate or cortisol) and proteins65-69.”
From Wearable biosensors for healthcare monitoring (2019) · cites this paper as [66]
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Cites
Fully integrated wearable sensor arrays for multiplexed in situ perspiration analysis
Gao, W., Emaminejad, S., Nyein, H. Y. Y., Challa, S., Chen, K., Peck, A., Fahad, H. M., Ota, H., Shiraki, H., Kiriya, D., et al. (2016) · Nature · doi:10.1038/nature16521 · Cited by 5,087 · see citing works
Bariya, M., Nyein, H. Y. Y., & Javey, A. (2018) · Nature Electronics · doi:10.1038/s41928-018-0043-y · Cited by 1,486 · see citing works
Gibson, L. E., & Cooke, R. E. (1959) · Pediatrics · doi:10.1542/peds.23.3.545 · Cited by 1,434 · see citing works
Wearable sensors: modalities, challenges, and prospects
Heikenfeld, J., Jajack, A., Rogers, J., Gutruf, P., Tian, L., Pan, T., Li, R., Khine, M., Kim, J., Wang, J., et al. (2018) · Lab on a Chip · doi:10.1039/c7lc00914c · Cited by 1,434 · see citing works
Self-citationGrant, B. F., Chou, S. P., Saha, T. D., Pickering, R. P., Kerridge, B. T., Ruan, W. J., Huang, B., Jung, J., Zhang, H., Fan, A., et al. (2017) · JAMA Psychiatry · doi:10.1001/jamapsychiatry.2017.2161 · Cited by 1,362 · see citing works
Boca, F. K. D., & Darkes, J. (2003) · Addiction · doi:10.1046/j.1359-6357.2003.00586.x · Cited by 1,138 · see citing works
Low-potential stable NADH detection at carbon-nanotube-modified glassy carbon electrodes
Musameh, M. M., Wang, J., Merkoçi, A., et al. (2002) · Electrochemistry Communications · doi:10.1016/s1388-2481(02)00451-4 · Cited by 1,067 · see citing works
Self-citationElectrochemical Tattoo Biosensors for Real-Time Noninvasive Lactate Monitoring in Human Perspiration
Jia, W., Bandodkar, A. J., Valdés-Ramírez, G., Windmiller, J. R., Yang, Z., Ramírez, J., Chan, G., & Wang, J. (2013) · Analytical Chemistry · doi:10.1021/ac401573r · Cited by 862 · see citing works
Self-citationEmaminejad, S., Gao, W., Wu, E., Davies, Z. A., Yin Yin Nyein, H., Challa, S., Ryan, S. P., Fahad, H. M., Chen, K., Shahpar, Z., et al. (2017) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1701740114 · Cited by 839 · see citing works
Wearable Chemical Sensors: Present Challenges and Future Prospects
Bandodkar, A. J., Jeerapan, I., & Wang, J. (2016) · ACS Sensors · doi:10.1021/acssensors.6b00250 · Cited by 778 · see citing works
Self-citationSonner, Z., Wilder, E., Heikenfeld, J., Kasting, G., Beyette, F., Swaile, D., Sherman, F., Joyce, J., Hagen, J., Kelley-Loughnane, N., et al. (2015) · Biomicrofluidics · doi:10.1063/1.4921039 · Cited by 724 · see citing works
Wearable Electrochemical Sensors and Biosensors: A Review
Windmiller, J. R., & Wang, J. (2012) · Electroanalysis · doi:10.1002/elan.201200349 · Cited by 699 · see citing works
Self-citationNoninvasive Alcohol Monitoring Using a Wearable Tattoo-Based Iontophoretic-Biosensing System
Kim, J., Jeerapan, I., Imani, S., Cho, T. N., Bandodkar, A., Cinti, S., Mercier, P. P., & Wang, J. (2016) · ACS Sensors · doi:10.1021/acssensors.6b00356 · Cited by 599 · see citing works
Self-citationWearable non-invasive epidermal glucose sensors: A review
Kim, J., Campbell, A. S., & Wang, J. (2017) · Talanta · doi:10.1016/j.talanta.2017.08.077 · Cited by 585 · see citing works
Self-citationStahre, M. A., Roeber, J., Kanny, D., Brewer, R. D., & Zhang, X. (2014) · Preventing Chronic Disease · doi:10.5888/pcd11.130293 · Cited by 561 · see citing works
Emerging flexible and wearable physical sensing platforms for healthcare and biomedical applications
Kenry, Yeo, J. C., & Lim, C. T. (2016) · Microsystems & Nanoengineering · doi:10.1038/micronano.2016.43 · Cited by 550 · see citing works
(2006) · Choice Reviews Online · doi:10.5860/choice.44-0939 · Cited by 535 · see citing works
Verbal report methods in clinical research on alcoholism: response bias and its minimization.
Babor, T. F., Stephens, R. S., & Marlatt, G. A. (1987) · Journal of Studies on Alcohol · doi:10.15288/jsa.1987.48.410 · Cited by 488 · see citing works
Martín, A., Kim, J., Kurniawan, J. F., Sempionatto, J. R., Moreto, J. R., Tang, G., Campbell, A. S., Shin, A., Lee, M. Y., Liu, X., et al. (2017) · ACS Sensors · doi:10.1021/acssensors.7b00729 · Cited by 475 · see citing works
Self-citationMeasuring Alcohol Consumption. Psychosocial and Biochemical Methods
Horwath, C. C. (1993) · Journal of Clinical Pathology · doi:10.1136/jcp.46.8.783-c · Cited by 439 · see citing works
Measuring Alcohol Consumption: Psychosocial and Biochemical Methods
Litten, R. Z., & Allen, J. P. (1992) · Medical Entomology and Zoology · Cited by 409 · see citing works
Continuous minimally-invasive alcohol monitoring using microneedle sensor arrays
Mohan, A. M. V., Windmiller, J. R., Mishra, R. K., & Wang, J. (2017) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2017.01.016 · Cited by 278 · see citing works
Self-citationPrevalence of Alcohol Dependence Among US Adult Drinkers, 2009–2011
Esser, M. B., Hedden, S. L., Kanny, D., Brewer, R. D., Gfroerer, J., & Naimi, T. S. (2014) · Preventing Chronic Disease · doi:10.5888/pcd11.140329 · Cited by 264 · see citing works
Ethanol biosensors based on alcohol oxidase
Azevedo, A. M., Prazeres, D. M. F., Cabral, J. M. S., & Fonseca, L. P. (2004) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2004.09.030 · Cited by 262 · see citing works
Adsorption and electrochemical oxidation behaviour of NADH at a clean platinum electrode
Jaegfeldt, H. (1980) · Journal of Electroanalytical Chemistry · doi:10.1016/s0022-0728(80)80381-0 · Cited by 213 · see citing works
Direct measurement of alcohol and its metabolites
Swift, R. M. (2003) · Addiction · doi:10.1046/j.1359-6357.2003.00605.x · Cited by 204 · see citing works
Selvam, A. P., Muthukumar, S., Kamakoti, V., & Prasad, S. (2016) · Scientific Reports · doi:10.1038/srep23111 · Cited by 143 · see citing works
Leffingwell, T. R., Cooney, N. J., Murphy, J. G., Luczak, S., Rosen, G., Dougherty, D. M., & Barnett, N. P. (2013) · Alcoholism: Clinical and Experimental Research · doi:10.1111/j.1530-0277.2012.01869.x · Cited by 142 · see citing works
Gamella, M., Campuzano, S., Manso, J., Rivera, G. G. D., López-Colino, F., Reviejo, A. J., & Pingarrón, J. M. (2014) · Analytica Chimica Acta · doi:10.1016/j.aca.2013.09.020 · Cited by 140 · see citing works
Studies on a Wearable, Electronic, Transdermal Alcohol Sensor
Swift, R. M., Martin, C. S., Swette, L., LaConti, A., & Kackley, N. (1992) · Alcoholism: Clinical and Experimental Research · doi:10.1111/j.1530-0277.1992.tb00668.x · Cited by 114 · see citing works
Validity of Transdermal Alcohol Monitoring: Fixed and Self‐Regulated Dosing
Sakai, J. T., Mikulich‐Gilbertson, S. K., Long, R. J., & Crowley, T. J. (2006) · Alcoholism Clinical and Experimental Research · doi:10.1111/j.1530-0277.2006.00004.x · Cited by 111 · see citing works
Barnett, N. P., Celio, M. A., Tidey, J. W., Murphy, J. G., Colby, S. M., & Swift, R. M. (2017) · Addiction · doi:10.1111/add.13767 · Cited by 111 · see citing works
Field and Laboratory Alcohol Detection With 2 Types of Transdermal Devices
Marques, P. R., & McKnight, A. S. (2009) · Alcoholism Clinical and Experimental Research · doi:10.1111/j.1530-0277.2008.00887.x · Cited by 102 · see citing works
Transdermal Alcohol Measurement for Estimation of Blood Alcohol Concentration
Swift, R. (2000) · Alcoholism: Clinical and Experimental Research · doi:10.1111/j.1530-0277.2000.tb02006.x · Cited by 101 · see citing works
Screen-printed biosensors using different alcohol oxidases
Patel, N. G., Meier, S., Cammann, K., et al. (2001) · Sensors and Actuators B Chemical · doi:10.1016/s0925-4005(01)00545-7 · Cited by 99 · see citing works
Dougherty, D. M., Charles, N. E., Acheson, A., John, S., Furr, R. M., & Hill‐Kapturczak, N. (2012) · Experimental and Clinical Psychopharmacology · doi:10.1037/a0029021 · Cited by 95 · see citing works
Nanjo, M., & Guilbault, G. G. (1975) · Analytica Chimica Acta · doi:10.1016/s0003-2670(01)81964-4 · Cited by 92 · see citing works
Advances in developing rapid, reliable and portable detection systems for alcohol
Thungon, P. D., Kakoti, A., Ngashangva, L., & Goswami, P. (2017) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2017.05.041 · Cited by 92 · see citing works
Venugopal, M., Feuvrel, K. E., Mongin, D., Bambot, S., Faupel, M., Panangadan, A., Talukder, A., & Pidva, R. (2008) · IEEE Sensors Journal · doi:10.1109/jsen.2007.912544 · Cited by 76 · see citing works
Sweat Ethanol Concentrations are Highly Correlated with Co‐Existing Blood Values in Humans
Buono, M. J. (1999) · Experimental Physiology · doi:10.1111/j.1469-445x.1999.01798.x · Cited by 74 · see citing works
The impact of non-concordant self-report of substance use in clinical trials research
Clark, C. B., Zyambo, C., Li, Y., & Cropsey, K. L. (2016) · Addictive Behaviours · doi:10.1016/j.addbeh.2016.02.023 · Cited by 70 · see citing works
Experiences with SCRAMx alcohol monitoring technology in 100 alcohol treatment outpatients
Alessi, S. M., Barnett, N. P., & Petry, N. M. (2017) · Drug and Alcohol Dependence · doi:10.1016/j.drugalcdep.2017.05.031 · Cited by 63 · see citing works
Thomas, L. C., & Chirstian, G. D. (1975) · Analytica Chimica Acta · doi:10.1016/s0003-2670(00)00146-x · Cited by 61 · see citing works
Time Delays in Transdermal Alcohol Concentrations Relative to Breath Alcohol Concentrations
Karns‐Wright, T. E., Roache, J. D., Hill‐Kapturczak, N., Liang, Y., Mullen, J., & Dougherty, D. M. (2016) · Alcohol and Alcoholism · doi:10.1093/alcalc/agw058 · Cited by 60 · see citing works
Ghica, M. E., Pauliukaitė, R., Marchand, N., et al. (2007) · Analytica Chimica Acta · doi:10.1016/j.aca.2007.03.047 · Cited by 58 · see citing works
Dumett, M. A., Rosen, I. G., Sabat, J., Shaman, A., Tempelman, L., Wang, C., & Swift, R. M. (2008) · Applied Mathematics and Computation · doi:10.1016/j.amc.2007.07.026 · Cited by 53 · see citing works
The Elimination of Ethyl Alcohol in Sweat<sup>1</sup>
Nyman, E., & Palmlöv, A. (1936) · Skandinavisches Archiv Für Physiologie · doi:10.1111/j.1748-1716.1936.tb01150.x · Cited by 47 · see citing works
(1985) · PubMed · Cited by 40 · see citing works
Fischer, U., Rebrin, K., von Woedtke, T., & Abel, P. (1994) · Hormone and Metabolic Research · doi:10.1055/s-2007-1001747 · Cited by 37 · see citing works
Immediate, quantitative estimation of blood alcohol concentration from saliva.
Bates, M. E., & Martin, C. S. (1997) · Journal of Studies on Alcohol · doi:10.15288/jsa.1997.58.531 · Cited by 36 · see citing works
Ayala, J., Simons, K., & Kerrigan, S. (2009) · Journal of Analytical Toxicology · doi:10.1093/jat/33.1.27 · Cited by 29 · see citing works
Use of a new sample-collection device (Macroduct) in anion analysis of human sweat.
Cole, D. E. C., & Boucher, M. J. (1986) · Clinical Chemistry · doi:10.1093/clinchem/32.7.1375 · Cited by 25 · see citing works
Simpson, G. (1987) · Clinical Chemistry · doi:10.1093/clinchem/33.2.261 · Cited by 25 · see citing works
Ali, S. S., Wilson, M. P., Castillo, E. M., et al. (2013) · Academic Emergency Medicine · doi:10.1111/acem.12073 · Cited by 17 · see citing works
THE ACCURACY OF BREATH ALCOHOL ANALYSIS USING THE BREATHALYZER
Worner, T. M., & Prabakaran, J. (1985) · Alcohol and Alcoholism · doi:10.1093/oxfordjournals.alcalc.a044545 · Cited by 13 · see citing works
Flagged first, then by citations
Cited by
Sorted by citations
Wearable biosensors for healthcare monitoring
Kim, J., Campbell, A. S., de Ávila, B. E.-F., & Wang, J. (2019) · Nature Biotechnology · doi:10.1038/s41587-019-0045-y · Cited by 3,373 · see citing works
Self-citationYang, J. C., Mun, J., Kwon, S. Y., Park, S., Bao, Z., & Park, S. (2019) · Advanced Materials · doi:10.1002/adma.201904765 · Cited by 1,641 · see citing works
Eyeglasses-based tear biosensing system: Non-invasive detection of alcohol, vitamins and glucose
Sempionatto, J. R., Brazaca, L. C., García-Carmona, L., Bolat, G., Campbell, A. S., Martin, A., Tang, G., Shah, R., Mishra, R. K., Kim, J., et al. (2019) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2019.04.058 · Cited by 315 · see citing works
Epidermal enzymatic biosensors for sweat vitamin C: Toward personalized nutrition
Sempionatto, J. R., Khorshed, A. A., Ahmed, A., De Loyola e Silva, A. N., Barfidokht, A., Yin, L., Goud, K. Y., Mohamed, M. A., Bailey, E., May, J., et al. (2020) · ACS Sensors · doi:10.1021/acssensors.0c00604 · Cited by 256 · see citing works
Self-citationFlexible Electrochemical Biosensors for Health Monitoring
Yang, A., & Yan, F. (2021) · ACS Applied Electronic Materials · doi:10.1021/acsaelm.0c00534 · Cited by 122 · see citing works
Davis-Martin, R. E., Alessi, S. M., & Boudreaux, E. D. (2021) · Frontiers in Psychiatry · doi:10.3389/fpsyt.2021.642813 · Cited by 54 · see citing works
- Authors
- Campbell, A. S., Kim, J., & Wang, J.
- Affiliations
- University of California San Diego (US)
- Corresponding author
- Wang, Joseph
- Venue
- Current Opinion in Electrochemistry
- Publisher
- Elsevier BV
- Published
- 2018-08
- Volume
- 10
- Pages
- 126-135
- ISSN
- 2451-9103 (ISSN-L)
- PMC
- PMC6407881
- OpenAlex
- W2804071681
- Cited by
- 140
- References
- 55
- Citations by year
- 2026: 11 · 2025: 11 · 2024: 16 · 2023: 18 · 2022: 18 · 2021: 26 · 2020: 23 · 2019: 13 · 2018: 4
- FWCI
- 0.92
- Type
- journal article
- Language
- en
- Open access
- bronze
- doi.org
- Licence
- Locations
- Current Opinion in Electrochemistry (acceptedVersion)
- PubMed (publishedVersion)
- Europe PMC (PubMed Central) (acceptedVersion)
- PubMed Central (acceptedVersion)
- Funders
- NIH (AA013525)
- Defense Threat Reduction Agency (HDTRA1-16-1-0013)
- Topics
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Electrochemical sensors and biosensors
- Physical Sciences › Engineering › Biomedical Engineering › Advanced Sensor and Energy Harvesting Materials
- Life Sciences › Biochemistry, Genetics and Molecular Biology › Molecular Biology › Advanced biosensing and bioanalysis techniques
- Keywords
- wearable biosensors, electrochemical biosensor, alcohol detection, sweat, skin interstitial fluid, on-body sensing, real-time monitoring
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review