Ascorbic and dehydroascorbic acids measured in plasma preserved with dithiothreitol or metaphosphoric acid
The DOI matches its Crossref record.
Abstract
We describe a rapid method for accurately and precisely measuring ascorbic acid and dehydroascorbic acid in plasma. Total analysis time is less than 10 min, replicate analyses of a single pool provide precision less than or equal to 2%, and values measured in supplemented samples agree with known concentrations of 4.68 and 11.83 mg/L. The stability and homogeneity of lyophilized plasma samples supplemented with ascorbic acid and dithiothreitol are documented. We also describe a procedure in which metaphosphoric acid (50 g/L) is used to prepare a reference material for the measurement of ascorbic acid and dehydroascorbic acid. The procedure for both acids consists of first measuring the native ascorbic acid, then reducing the dehydroascorbic acid, at neutral pH, with dithiothreitol, and finally measuring the total ascorbic acid; dehydroascorbic acid is then determined by difference. The metaphosphoric-acid-treated samples were stable at -70 degrees C, but stability decreased with temperature over the range examined, 4-50 degrees C.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Berger, M. M., Shenkin, A., Schweinlin, A., Amrein, K., Augsburger, M., Biesalski, H.-K., Bischoff, S. C., Casaer, M. P., Gundogan, K., Lepp, H.-L., et al. (2022) · Clinical Nutrition · doi:10.1016/j.clnu.2022.02.015 · Cited by 615
Vitamin Analysis for the Health and Food Sciences
Eitenmiller, R., & Landen, W. (1998) · CRC Press eBooks · doi:10.1201/9781420050165 · Cited by 546
The redox couple between glutathione and ascorbic acid: A chemical and physiological perspective
Winkler, B. S., Orselli, S. M., & Rex, T. S. (1994) · Free Radical Biology and Medicine · doi:10.1016/0891-5849(94)90019-1 · Cited by 488
Vegetables, fruits, and carotenoids and the risk of cancer
Ziegler, R. (1991) · The American Journal of Clinical Nutrition · doi:10.1093/ajcn/53.1.251s · Cited by 466
Self-citationTsai, K., Wang, S.-S., Chen, T.-S., Kong, C.-W., Chang, F.-Y., Lee, S.-D., & Lu, F.-J. (1998) · Gut · doi:10.1136/gut.42.6.850 · Cited by 164
Lykkesfeldt, J. (2012) · Nutrition Research · doi:10.1016/j.nutres.2011.11.005 · Cited by 43
“The stabilization of ASC and DHA in plasma and serum samples has been studied previously [1-7].”
BackgroundFurusawa, H., Sato, Y., Tanaka, Y., Inai, Y., Amano, A., Iwama, M., Kondo, Y., Handa, S., Murata, A., Nishikimi, M., et al. (2008) · Biological and Pharmaceutical Bulletin · doi:10.1248/bpb.31.1673 · Cited by 42
Metadata
- Authors
- Margolis, S. A., Paule, R. C., & Ziegler, R. G.
- Venue
- Clinical Chemistry
- Publisher
- Oxford University Press (OUP)
- Published
- 1990-10-01
- Volume
- 36
- Issue
- 10
- Pages
- 1750-1755
- ISSN
- 0009-9147 (ISSN-L)
- 1530-8561
- OpenAlex
- W1936305204
- Cited by
- 68
- References
- 0
- FWCI
- 2.72
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.