Immunological assays of apolipoproteins in plasma: methods and instrumentation
The DOI matches its Crossref record.
Abstract
A number of immunological techniques--radioimmunoassay, enzyme-linked immunosorbent assay (ELISA), electroimmunoassay, radial immunodiffusion, and a variety of immunoprecipitin assays--have been used to quantify apolipoproteins in plasma. This paper outlines their technical details and discusses their major advantages and drawbacks. The most sensitive procedures, RIAs and ELISAS, are best suited to quantifying those apoproteins found in low concentration in plasma. Immunoturbidimetric assays, on the other hand, which are readily automated, are being widely used to quantify apolipoproteins A-I and B. Apolipoprotein quantification is complicated by the interaction of the proteins with lipids, which can often mask their antigenic determinants. This problem may be circumvented by pretreatment of the samples, by selection of appropriate standards, or by the use of polyclonal or monoclonal antibodies that interact with permanently exposed epitopes on the lipoproteins' surfaces. Our proposed methods for measurement of the individual apolipoproteins give consideration to these approaches.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Demeester, N., Castro, G., Desrumaux, C., De Geitere, C., Fruchart, J. C., Santens, P., Mulleners, E., Engelborghs, S., De Deyn, P. P., Vandekerckhove, J., et al. (2000) · Journal of Lipid Research · doi:10.1016/s0022-2275(20)32039-3 · Cited by 140
Self-citationEffect of Domain Interaction on Apolipoprotein E Levels in Mouse Brain
Ramaswamy, G., Xu, Q., Huang, Y., & Weisgraber, K. H. (2005) · The Journal of Neuroscience · doi:10.1523/jneurosci.1922-05.2005 · Cited by 87
Clouet-Foraison, N., Gaie-Levrel, F., Gillery, P., & Delatour, V. (2017) · Clinical Chemistry and Laboratory Medicine (CCLM) · doi:10.1515/cclm-2017-0091 · Cited by 30
Long, S., Tian, Y., Zhang, R., Yang, L., Xu, Y., Jia, L., & Fu, M. (2006) · Clinica Chimica Acta · doi:10.1016/j.cca.2005.11.010 · Cited by 21
Metadata
- Authors
- Labeur, C., Shepherd, J., & Rosseneu, M.
- Venue
- Clinical Chemistry
- Publisher
- Oxford University Press (OUP)
- Published
- 1990-04-01
- Volume
- 36
- Issue
- 4
- Pages
- 591-597
- ISSN
- 0009-9147 (ISSN-L)
- 1530-8561
- OpenAlex
- W2148607472
- Cited by
- 85
- References
- 0
- FWCI
- 7.38
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Immunological assays of apolipoproteins in plasma: methods and instrumentation. https://app.cochat.ai/papers/10.1093/clinchem/36.4.591
- The paper
- Labeur, C., Shepherd, J., & Rosseneu, M. (1990). Immunological assays of apolipoproteins in plasma: methods and instrumentation. Clinical Chemistry. https://doi.org/10.1093/clinchem/36.4.591
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.