Development, validation, and certification by isotope dilution gas chromatography-mass spectrometry of lyophilized human serum reference materials for cortisol (CRM 192 and 193) and progesterone (CRM 347 and 348)
The DOI matches its Crossref record.
Abstract
The Community Bureau of Reference of the European Communities has produced four batches of lyophilized serum Certified Reference Materials, two for cortisol (CRM 192 and 193) and two for progesterone (CRM 347 and 348). For cortisol, one of the pools consisted of serum from healthy blood donors, whereas the second batch was supplemented with pure cortisol. The progesterone Reference Materials contained only endogenous hormone concentrations. Assessment of vial-to-vial variability in the cortisol and progesterone concentrations showed no between-sample inhomogeneity, and the materials were stable. The quality of the materials was therefore considered sufficient for certification of the values for the cortisol and progesterone concentrations by a collaborative study involving several laboratories from the European Communities, using isotope dilution gas chromatography-mass spectrometry. Inaccuracy in reconstitution of the lyophilized materials was less than 0.3%; imprecision of sampling was less than 0.2%. For determinations of cortisol and progesterone concentrations, the mean within-laboratory coefficients of variation (CVs) were 1.76% (CRM 192), 1.19% (CRM 193), 1.64% (CRM 347), and 1.75% (CRM 348). The between-laboratory CVs were greater: CRM 192, 1.79%; CRM 193, 1.48%; CRM 347, 2.08%; and CRM 348, 2.16%. The concentrations in the reconstituted Reference Materials were certified to be 273 nmol/L in CRM 192 and 763 nmol/L in CRM 193 for cortisol and 10.13 nmol/L in CRM 347 and 40.3 nmol/L in CRM 348 for progesterone. Uncertainties at the 0.95 confidence level--6 (CRM 192), 14 (CRM 193), 0.21 (CRM 347), and 1.0 nmol/L (CRM 348)--were considered compatible with the intended use of the materials.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Shackleton, C. (2010) · The Journal of Steroid Biochemistry and Molecular Biology · doi:10.1016/j.jsbmb.2010.02.017 · Cited by 226
Determination of cortisol in serum, saliva and urine
Turpeinen, U., & Hämäläinen, E. (2013) · Best Practice & Research Clinical Endocrinology & Metabolism · doi:10.1016/j.beem.2013.10.008 · Cited by 214
Cheney, D., Uzunov, D., Costa, E., & Guidotti, A. (1995) · The Journal of Neuroscience · doi:10.1523/jneurosci.15-06-04641.1995 · Cited by 167
LC–MS/MS analysis of steroids in the clinical laboratory
Keevil, B. G. (2016) · Clinical Biochemistry · doi:10.1016/j.clinbiochem.2016.04.009 · Cited by 149
Carvalho, V. M. (2012) · Journal of Chromatography B · doi:10.1016/j.jchromb.2011.08.027 · Cited by 90
Metadata
- Authors
- Thienpont, L., Siekmann, L., Lawson, A., Colinet, E., & De Leenheer, A.
- Venue
- Clinical Chemistry
- Publisher
- Oxford University Press (OUP)
- Published
- 1991-04-01
- Volume
- 37
- Issue
- 4
- Pages
- 540-546
- ISSN
- 0009-9147 (ISSN-L)
- 1530-8561
- OpenAlex
- W2153633636
- Cited by
- 47
- References
- 0
- FWCI
- 2.43
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Development, validation, and certification by isotope dilution gas chromatography-mass spectrometry of lyophilized human serum reference materials for cortisol (CRM 192 and 193) and progesterone (CRM 347 and 348). https://app.cochat.ai/papers/10.1093/clinchem/37.4.540
- The paper
- Thienpont, L., Siekmann, L., Lawson, A., Colinet, E., & De Leenheer, A. (1991). Development, validation, and certification by isotope dilution gas chromatography-mass spectrometry of lyophilized human serum reference materials for cortisol (CRM 192 and 193) and progesterone (CRM 347 and 348). Clinical Chemistry. https://doi.org/10.1093/clinchem/37.4.540
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.