Detection of toluenediamines in the urine of a patient with polyurethane-covered breast implants
The DOI matches its Crossref record.
Abstract
Breast prostheses are implanted for augmentation or during reconstructive surgery. One of the more commonly used prostheses is the polyurethane-sponge-covered silicone gel implant. Some clinicians are concerned about the safety of this product because the polyurethane foam disintegrates in vivo, and its subsequent fate is not known. Polyurethane is a polymer formed by reacting diisocyanates and polyols. This study indicates that the polymer sponge breaks down into its reactive monomers, 2,4- and 2,6-toluenediisocyanate, which are converted into their corresponding diamines. We present evidence of the excretion of the diamine metabolites in the urine of a patient implanted with polyurethane-covered prostheses.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Inflammatory Responses to Biomaterials
Tang, L., & Eaton, J. W. (1995) · American Journal of Clinical Pathology · doi:10.1093/ajcp/103.4.466 · Cited by 481
Fibrin(ogen) mediates acute inflammatory responses to biomaterials.
Tang, L., & Eaton, J. W. (1993) · The Journal of experimental medicine · doi:10.1084/jem.178.6.2147 · Cited by 449
Molecular basis of biomaterial-mediated foreign body reactions
Hu, W.-J., Eaton, J. W., Ugarova, T. P., & Tang, L. (2001) · Blood · doi:10.1182/blood.v98.4.1231 · Cited by 431
Mast cells mediate acute inflammatory responses to implanted biomaterials
Tang, L., Jennings, T. A., & Eaton, J. W. (1998) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.95.15.8841 · Cited by 272
Pinchuk, L. (1995) · Journal of Biomaterials Science, Polymer Edition · doi:10.1163/156856294x00347 · Cited by 252
Metadata
- Authors
- Chan, S. C., Birdsell, D. C., & Gradeen, C. Y.
- Venue
- Clinical Chemistry
- Publisher
- Oxford University Press (OUP)
- Published
- 1991-05-01
- Volume
- 37
- Issue
- 5
- Pages
- 756-758
- ISSN
- 0009-9147 (ISSN-L)
- 1530-8561
- OpenAlex
- W1874135217
- Cited by
- 62
- References
- 0
- FWCI
- 7.81
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Detection of toluenediamines in the urine of a patient with polyurethane-covered breast implants. https://app.cochat.ai/papers/10.1093/clinchem/37.5.756
- The paper
- Chan, S. C., Birdsell, D. C., & Gradeen, C. Y. (1991). Detection of toluenediamines in the urine of a patient with polyurethane-covered breast implants. Clinical Chemistry. https://doi.org/10.1093/clinchem/37.5.756
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.