The DOI matches its Crossref record.
Development and In Vitro Characterization of a New Immunoassay of Cardiac Troponin T
Abstract
We describe a new one-step enzyme immunoassay of troponin T that uses two specific monoclonal antibodies and streptavidin-coated tubes as the solid phase. The monoclonal antibodies were obtained by conventional hybridoma technology, with human troponin T as antigen. The identity of the cardiac troponin T antigen was confirmed by analysis of the amino acid composition and by partial sequence analysis. The specificity of the monoclonal antibodies for cardiac troponin T was proved by immunoblot analysis and displacement curves. The capture antibody is labeled with biotin. The second antibody is conjugated to horseradish peroxidase (EC 1.11.1.7). The assay [Enzymun-TestR system (Boehringer Mannheim GmbH)] is performed in only 90 min at room temperature; the measuring range for troponin T is 0.1 to 15 micrograms/L. The assay shows excellent between-run precision (CV = 3.3-4.9%).
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Biochemical markers of myocardial injury. Is MB creatine kinase the choice for the 1990s?
Adams, J. E., Abendschein, D. R., & Jaffe, A. S. (1993) · Circulation · doi:10.1161/01.cir.88.2.750 · Cited by 554
Cardiac Troponin T in Patients With Clinically Suspected Myocarditis
Lauer, B., Niederau, C., Kühl, U., Schannwell, M., Pauschinger, M., Strauer, B.-E., & Schultheiss, H.-P. (1997) · Journal of the American College of Cardiology · doi:10.1016/s0735-1097(97)00317-3 · Cited by 477
Heeschen, C., Hamm, C. W., Bruemmer, J., & Simoons, M. L. (2000) · Journal of the American College of Cardiology · doi:10.1016/s0735-1097(00)00581-7 · Cited by 414
High-sensitivity assays for troponin in patients with cardiac disease
Westermann, D., Neumann, J. T., Sörensen, N. A., & Blankenberg, S. (2017) · Nature Reviews Cardiology · doi:10.1038/nrcardio.2017.48 · Cited by 222
Metadata
- Authors
- Katus, H. A., Looser, S., Hallermayer, K., Remppis, A., Scheffold, T., Borgya, A., Essig, U., & Geuss, U.
- Venue
- Clinical Chemistry
- Publisher
- Oxford University Press (OUP)
- Published
- 1992-03-01
- Volume
- 38
- Issue
- 3
- Pages
- 386-393
- ISSN
- 0009-9147 (ISSN-L)
- 1530-8561
- OpenAlex
- W1947889433
- Cited by
- 430
- References
- 0
- FWCI
- 23.72
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Development and In Vitro Characterization of a New Immunoassay of Cardiac Troponin T. https://app.cochat.ai/papers/10.1093/clinchem/38.3.386
- The paper
- Katus, H. A., Looser, S., Hallermayer, K., Remppis, A., Scheffold, T., Borgya, A., Essig, U., & Geuss, U. (1992). Development and In Vitro Characterization of a New Immunoassay of Cardiac Troponin T. Clinical Chemistry. https://doi.org/10.1093/clinchem/38.3.386
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.