We have evaluated Micral-Test, an immunochemical strip test specific for albumin, as a screening tool for slight ("micro") albuminuria. First morning urine samples containing albumin concentrations (by radioimmunoassay) of 0.4-440 mg/L were collected from 112 diabetic patients. The Micral-Test result for each sample was assessed by one observer. All 34 samples having albumin concentrations greater than or equal to 20 mg/L and 71 of 78 samples less than 20 mg/L were correctly identified, giving 100% sensitivity and 91% specificity. Six samples were measured 10 times by one observer: three samples were read consistently; one, albumin concentration 86 mg/L, was read as 50 and 100 mg/L; and two, albumin concentrations 32 and 38 mg/L, were read as 20 and 50 mg/L, respectively. Contact with urine for 2 s rather than the recommended 5 s resulted in an underestimation of the albumin concentration in 13 of 35 samples (Z = -3.18, P = 0.001), as did taking readings earlier than the recommended 5 min (Z = -3.92, P less than 0.001). Six observers independently performed Micral-Test measurements on 10 samples. Eight samples were correctly classified as greater than or equal to 20 or less than 20 mg/L by all observers, but two (albumin concentrations 25 and 18 mg/L) were misclassified by at least one observer. The Micral-Test is a sensitive and specific screening tool, but is semiquantitative and critically time dependent.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Feldt-Rasmussen, B., Mathiesen, E., & Deckert, T. (1986) · The Lancet · doi:10.1016/s0140-6736(86)91433-9 · Cited by 447
Cited by
KDIGO 2024 clinical practice guideline for the evaluation and management of chronic kidney disease
Stevens, P. E., Ahmed, S. B., Carrero, J. J., Foster, B., Francis, A., Hall, R. K., Herrington, W. G., Hill, G., Inker, L. A., Kazancıoğlu, R., et al. (2024) · Kidney International · doi:10.1016/j.kint.2023.10.018 · Cited by 8,530
Blood pressure and renal function seven years after pregnancy complicated by hypertension
Nisell, H., Lintu, H., Lunell, N. O., Möllerström, G., & Pettersson, E. (1995) · BJOG: An International Journal of Obstetrics & Gynaecology · doi:10.1111/j.1471-0528.1995.tb10874.x · Cited by 174
Meinhardt, U. (2003) · Journal of Diabetes and its Complications · doi:10.1016/s1056-8727(02)00180-0 · Cited by 38
Sacks, D. B. (2012) · Tietz Textbook of Clinical Chemistry and Molecular Diagnostics · doi:10.1016/b978-1-4160-6164-9.00046-9 · Cited by 7
Metadata
- Authors
- Marshall, S. M., Shearing, P. A., & Alberti, K. G.
- Venue
- Clinical Chemistry
- Publisher
- Oxford University Press (OUP)
- Published
- 1992-04-01
- Volume
- 38
- Issue
- 4
- Pages
- 588-591
- ISSN
- 0009-9147 (ISSN-L)
- 1530-8561
- OpenAlex
- W1584871550
- Cited by
- 47
- References
- 1
- FWCI
- 3.19
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Micral-Test Strips Evaluated for Screening for Albuminuria. https://app.cochat.ai/papers/10.1093/clinchem/38.4.588
- The paper
- Marshall, S. M., Shearing, P. A., & Alberti, K. G. (1992). Micral-Test Strips Evaluated for Screening for Albuminuria. Clinical Chemistry. https://doi.org/10.1093/clinchem/38.4.588
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.