The DOI matches its Crossref record.
Malondialdehyde Kit Evaluated for Determining Plasma and Lipoprotein Fractions that React with Thiobarbituric Acid
Abstract
The determination of thiobarbituric acid reactants (TBARs) is a widely used method for investigating overall lipid peroxidation. An assay kit that could be used with plasma and lipid fractions would facilitate standardization of the method. The results reported here indicate that the malondialdehyde (MDA) kit manufactured by Sobioda (Grenoble, France) complies with criteria of good analytical practices. The detection limit was 0.11 mumol of MDA per liter of plasma. The within-run (CV = 1.8-3.3%) and between-run (CV = 3.3-4.4%) precisions were acceptable. The analytical recovery of MDA after supplementing human plasma samples with tetraethoxypropane standards varied from 88% to 100%. The mean (SD) lipoperoxide concentration determined in 32 healthy adults, ages 20-40 years, was 2.51 (0.25) mumol/L. No significant sex-related difference was noted: 2.57 (0.28) in men vs 2.44 (0.20) mumol/L in women. Applying the method to lipid fractions showed that lipoprotein fractions contain relatively little MDA: 0.07 (0.03) mumol/L of plasma for very-low-density lipoproteins and 0.19 (0.10) mumol/L for low-density lipoproteins.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Improved analysis of malondialdehyde in human body fluids
Jentzsch, A. M., Bachmann, H., Fürst, P., & Biesalski, H. K. (1996) · Free Radical Biology and Medicine · doi:10.1016/0891-5849(95)02043-8 · Cited by 802
Wasowicz, W., Nève, J., & Peretz, A. (1993) · Clinical Chemistry · doi:10.1093/clinchem/39.12.2522 · Cited by 639
Anderson, R. A., Roussel, A.-M., Zouari, N., Mahjoub, S., Matheau, J.-M., & Kerkeni, A. (2001) · Journal of the American College of Nutrition · doi:10.1080/07315724.2001.10719034 · Cited by 313
Plasma malondialdehyde in type 1 and type 2 diabetic patients
Gallou, G., Ruelland, A., Legras, B., Maugendre, D., Allannic, H., & Cloarec, L. (1993) · Clinica Chimica Acta · doi:10.1016/0009-8981(93)90114-j · Cited by 167
Increased Lipid Peroxidation in Pregnant Women after Iron and Vitamin C Supplementation
Lachili, B., Hininger, I., Faure, H., Arnaud, J., Richard, M.-J., Favier, A., & Roussel, A.-M. (2001) · Biological Trace Element Research · doi:10.1385/bter:83:2:103 · Cited by 116
Self-citation
Metadata
- Authors
- Richard, M. J., Portal, B., Meo, J., Coudray, C., Hadjian, A., & Favier, A.
- Venue
- Clinical Chemistry
- Publisher
- Oxford University Press (OUP)
- Published
- 1992-05-01
- Volume
- 38
- Issue
- 5
- Pages
- 704-709
- ISSN
- 0009-9147 (ISSN-L)
- 1530-8561
- OpenAlex
- W1935160261
- Cited by
- 304
- References
- 0
- FWCI
- 5.65
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Malondialdehyde Kit Evaluated for Determining Plasma and Lipoprotein Fractions that React with Thiobarbituric Acid. https://app.cochat.ai/papers/10.1093/clinchem/38.5.704
- The paper
- Richard, M. J., Portal, B., Meo, J., Coudray, C., Hadjian, A., & Favier, A. (1992). Malondialdehyde Kit Evaluated for Determining Plasma and Lipoprotein Fractions that React with Thiobarbituric Acid. Clinical Chemistry. https://doi.org/10.1093/clinchem/38.5.704
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.