Immunonephelometric Assay of Vitamin D-Binding Protein
The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
An automated immunonephelometric assay was developed to measure vitamin D-binding protein (DBP) in serum. The assay is described for the Behring Nephelometer System, which uses rabbit anti-DBP antiserum and purified human DBP. The detection limit is 0.05 g/L (0.86 mumol/L), and the working range is less than or equal to 1.60 g/L (27.59 mumol/L). Intra- and interassay CVs of 2.0% and 2.8-3.8% compare favorably with alternative methods. When results were compared with those from a immunoradiometric assay, the correlation coefficient was 0.976 (P less than 0.001), and the regression equation [y = 0.866 +/- 0.085x + 0.05 (Syx = 0.042, n = 42)] identified a negative bias. Analysis indicated that both methods appeared to contribute equally to the bias. Although the assay was relatively free from analytical interference, falsely increased values were noted in severely lipemic specimens and in frozen specimens. Interference may be minimized by inclusion of Supplementary Precipitation reagent in a modified assay protocol. The range of concentrations expected in clinical samples was established from normal subjects [0.32-0.46 g/L (5.52-7.93 mumol/L), n = 28], pregnant subjects [0.51-0.70 g/L (8.79-12.07 mumol/L), n = 13], and subjects with liver diseases [0.12-0.33 g/L (2.07-5.69 mumol/L), n = 18].
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Bikle, D. D., Halloran, B. P., Gee, E., Ryzen, E., & Haddad, J. G. (1986) · Journal of Clinical Investigation · doi:10.1172/jci112636 · Cited by 158
Cited by
Common genetic determinants of vitamin D insufficiency: a genome-wide association study
Wang, T. J., Zhang, F., Richards, J. B., Kestenbaum, B., van Meurs, J. B., Berry, D., Kiel, D. P., Streeten, E. A., Ohlsson, C., Koller, D. L., et al. (2010) · The Lancet · doi:10.1016/s0140-6736(10)60588-0 · Cited by 1,540
Hollis, B. W., Johnson, D., Hulsey, T. C., Ebeling, M., & Wagner, C. L. (2011) · Journal of Bone and Mineral Research · doi:10.1002/jbmr.463 · Cited by 846
Pludowski, P., Holick, M. F., Pilz, S., Wagner, C. L., Hollis, B. W., Grant, W. B., Shoenfeld, Y., Lerchbaum, E., Llewellyn, D. J., Kienreich, K., et al. (2013) · Autoimmunity Reviews · doi:10.1016/j.autrev.2013.02.004 · Cited by 836
Biological and clinical aspects of the vitamin D binding protein (Gc-globulin) and its polymorphism
Speeckaert, M., Huang, G., Delanghe, J. R., & Taes, Y. E. C. (2006) · Clinica Chimica Acta · doi:10.1016/j.cca.2006.03.011 · Cited by 480
Seymour, J., & Gagel, R. (1993) · Blood · doi:10.1182/blood.v82.5.1383.1383 · Cited by 291
Metadata
- Authors
- Haughton, M. A., & Mason, R. S.
- Venue
- Clinical Chemistry
- Publisher
- Oxford University Press (OUP)
- Published
- 1992-09-01
- Volume
- 38
- Issue
- 9
- Pages
- 1796-1801
- ISSN
- 0009-9147 (ISSN-L)
- 1530-8561
- OpenAlex
- W2102925529
- Cited by
- 35
- References
- 1
- FWCI
- 0.41
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.