Ionic binding, net charge, and Donnan effect of human serum albumin as a function of pH
The DOI matches its Crossref record.
Abstract
The ionic activities and total molalities of sodium, potassium, calcium, lithium, and chloride in a solution of human serum albumin were measured at different values of pH between 4 and 9. The same quantities were measured simultaneously in a protein-free electrolyte solution in membrane equilibrium with the albumin solution. Taking the residual liquid-junction potential and bias from unselectivity of the electrodes into account, we determined the own, bound, and net charges of albumin. Chloride was amply bound at low pH, and calcium at high pH. The varying charge of ions bound to albumin opposed the effect of acid or base on the net charge. All ions were distributed across the membrane according to the same electric potential difference, which equalled the Donnan potential. The high concordance between observation and theory favors the Donnan theory and furthermore implies that the electrodes are as accurate in a solution with albumin as in a protein-free solution.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
A Reappraisal of Testosterone’s Binding in Circulation: Physiological and Clinical Implications
Goldman, A. L., Bhasin, S., Wu, F. C. W., Krishna, M., Matsumoto, A. M., & Jasuja, R. (2017) · Endocrine Reviews · doi:10.1210/er.2017-00025 · Cited by 414
Current issues in measurement and reporting of urinary albumin excretion
Miller, W. G., Bruns, D. E., Hortin, G. L., Sandberg, S., Aakre, K. M., McQueen, M. J., Itoh, Y., Lieske, J. C., Seccombe, D. W., Jones, G., et al. (2009) · Clinical Chemistry · doi:10.1373/clinchem.2008.106567 · Cited by 381
Composition of interstitial fluid
Fogh-Andersen, N., Altura, B. M., Altura, B. T., & Siggaard-Andersen, O. (1995) · Clinical Chemistry · doi:10.1093/clinchem/41.10.1522 · Cited by 309
Self-citationJolly, P., Tamboli, V., Harniman, R. L., Estrela, P., Allender, C. J., & Bowen, J. L. (2016) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2015.08.043 · Cited by 286
Magnesium in critical illness: metabolism, assessment, and treatment
Noronha, L. J., & Matuschak, G. M. (2002) · Intensive Care Medicine · doi:10.1007/s00134-002-1281-y · Cited by 249
Metadata
- Authors
- Fogh-Andersen, N., Bjerrum, P. J., & Siggaard-Andersen, O.
- Venue
- Clinical Chemistry
- Publisher
- Oxford University Press (OUP)
- Published
- 1993-01-01
- Volume
- 39
- Issue
- 1
- Pages
- 48-52
- ISSN
- 0009-9147 (ISSN-L)
- 1530-8561
- OpenAlex
- W2166644926
- Cited by
- 147
- References
- 0
- FWCI
- 1.62
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Ionic binding, net charge, and Donnan effect of human serum albumin as a function of pH. https://app.cochat.ai/papers/10.1093/clinchem/39.1.48
- The paper
- Fogh-Andersen, N., Bjerrum, P. J., & Siggaard-Andersen, O. (1993). Ionic binding, net charge, and Donnan effect of human serum albumin as a function of pH. Clinical Chemistry. https://doi.org/10.1093/clinchem/39.1.48
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.