The DOI matches its Crossref record.
Determination of metanephrines in plasma by liquid chromatography with electrochemical detection
Abstract
Metanephrines are O-methylated metabolites of catecholamines. We report the use of liquid chromatography with electrochemical detection to determine plasma concentrations of normetanephrine (NMN) and metanephrine (MN). Plasma NMN and MN in 32 normal volunteers and inpatients were compared with concentrations in 23 patients with pheochromocytoma. Metanephrines were adsorbed from plasma onto a cation-exchange column and eluted with ammoniacal methanol. The dried residue was dissolved in mobile phase and injected onto a reversed-phase column. Recoveries of NMN and MN from 1 mL of plasma averaged 50-70%, and results varied linearly with quantity injected over a range of 0.13-55 pmol. The detection limit was 25 fmol for NMN and 50 fmol for MN. Intra-assay CVs were < 5%. In normal volunteers and inpatients, plasma concentrations of NMN ranged between 0.12 and 0.73 nmol/L (mean 0.38 nmol/L), and MN between 0.06 and 0.63 nmol/L (mean 0.19 nmol/L). Plasma NMN concentrations were increased in all 23 patients with pheochromocytoma (range 1-172 nmol/L), whereas MN concentrations (range 0.10-382 nmol/L) were increased in only 9 patients. The assay method is reliable and sensitive and offers an approach to examine the extraneuronal metabolism of catecholamines. The method may also be useful in the diagnosis of pheochromocytoma.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Pheochromocytoma and paraganglioma: an endocrine society clinical practice guideline
Lenders, J. W. M., Duh, Q.-Y., Eisenhofer, G., Gimenez-Roqueplo, A.-P., Grebe, S. K. G., Murad, M. H., Naruse, M., Pacak, K., & Young, W. F. (2014) · The Journal of Clinical Endocrinology & Metabolism · doi:10.1210/jc.2014-1498 · Cited by 2,827
Self-citationLenders, J. W., Eisenhofer, G., Mannelli, M., & Pacak, K. (2005) · The Lancet · doi:10.1016/s0140-6736(05)67139-5 · Cited by 1,524
Self-citationCatecholamine Metabolism: A Contemporary View with Implications for Physiology and Medicine
Eisenhofer, G., Kopin, I. J., & Goldstein, D. S. (2004) · Pharmacological Reviews · doi:10.1124/pr.56.3.1 · Cited by 1,072
Self-citationSawka, A. M., Jaeschke, R., Singh, R. J., & Young, W. F. (2003) · The Journal of Clinical Endocrinology & Metabolism · doi:10.1210/jc.2002-021251 · Cited by 503
Biochemical Diagnosis of Pheochromocytoma: How to Distinguish True- from False-Positive Test Results
Eisenhofer, G., Goldstein, D. S., Walther, M. M., Friberg, P., Lenders, J. W. M., Keiser, H. R., & Pacak, K. (2003) · The Journal of Clinical Endocrinology & Metabolism · doi:10.1210/jc.2002-030005 · Cited by 492
Self-citation
Metadata
- Authors
- Lenders, J. W., Eisenhofer, G., Armando, I., Keiser, H. R., Goldstein, D. S., & Kopin, I. J.
- Venue
- Clinical Chemistry
- Publisher
- Oxford University Press (OUP)
- Published
- 1993-01-01
- Volume
- 39
- Issue
- 1
- Pages
- 97-103
- ISSN
- 0009-9147 (ISSN-L)
- 1530-8561
- OpenAlex
- W2101065691
- Cited by
- 220
- References
- 0
- FWCI
- 3.86
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Determination of metanephrines in plasma by liquid chromatography with electrochemical detection. https://app.cochat.ai/papers/10.1093/clinchem/39.1.97
- The paper
- Lenders, J. W., Eisenhofer, G., Armando, I., Keiser, H. R., Goldstein, D. S., & Kopin, I. J. (1993). Determination of metanephrines in plasma by liquid chromatography with electrochemical detection. Clinical Chemistry. https://doi.org/10.1093/clinchem/39.1.97
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.