Abstract
Metanephrines are O-methylated metabolites of catecholamines. We report the use of liquid chromatography with electrochemical detection to determine plasma concentrations of normetanephrine (NMN) and metanephrine (MN). Plasma NMN and MN in 32 normal volunteers and inpatients were compared with concentrations in 23 patients with pheochromocytoma. Metanephrines were adsorbed from plasma onto a cation-exchange column and eluted with ammoniacal methanol. The dried residue was dissolved in mobile phase and injected onto a reversed-phase column. Recoveries of NMN and MN from 1 mL of plasma averaged 50-70%, and results varied linearly with quantity injected over a range of 0.13-55 pmol. The detection limit was 25 fmol for NMN and 50 fmol for MN. Intra-assay CVs were < 5%. In normal volunteers and inpatients, plasma concentrations of NMN ranged between 0.12 and 0.73 nmol/L (mean 0.38 nmol/L), and MN between 0.06 and 0.63 nmol/L (mean 0.19 nmol/L). Plasma NMN concentrations were increased in all 23 patients with pheochromocytoma (range 1-172 nmol/L), whereas MN concentrations (range 0.10-382 nmol/L) were increased in only 9 patients. The assay method is reliable and sensitive and offers an approach to examine the extraneuronal metabolism of catecholamines. The method may also be useful in the diagnosis of pheochromocytoma.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Pheochromocytoma and paraganglioma: an endocrine society clinical practice guideline
Lenders, J. W. M., Duh, Q.-Y., Eisenhofer, G., Gimenez-Roqueplo, A.-P., Grebe, S. K. G., Murad, M. H., Naruse, M., Pacak, K., & Young, W. F. (2014) · The Journal of Clinical Endocrinology & Metabolism · doi:10.1210/jc.2014-1498 · Cited by 2,827
Self-citationLenders, J. W., Eisenhofer, G., Mannelli, M., & Pacak, K. (2005) · The Lancet · doi:10.1016/s0140-6736(05)67139-5 · Cited by 1,524
Self-citationCatecholamine Metabolism: A Contemporary View with Implications for Physiology and Medicine
Eisenhofer, G., Kopin, I. J., & Goldstein, D. S. (2004) · Pharmacological Reviews · doi:10.1124/pr.56.3.1 · Cited by 1,072
“…the concepts established by Sjoerdsma, Crout, Kopin, and others in the 1950s and 60s have been revived by development of improved methods for measuring catecholamine metabolites, particularly plasma concentrations of free (unconjugated) normetanephrine and metanephrine (Lenders et al., 1993).”
BackgroundMethodSelf-citationSawka, A. M., Jaeschke, R., Singh, R. J., & Young, W. F. (2003) · The Journal of Clinical Endocrinology & Metabolism · doi:10.1210/jc.2002-021251 · Cited by 503
“Fractionated plasma metanephrines were measured by the Endocrine Laboratory at Mayo Medical Center using liquid chromatography with electrochemical detection and reported as metanephrine and normetanephrine fractions (8).”
MethodPheochromocytoma: State-of-the-Art and Future Prospects
Bravo, E. L., & Tagle, R. (2003) · Endocrine Reviews · doi:10.1210/er.2002-0013 · Cited by 493
Biochemical Diagnosis of Pheochromocytoma: How to Distinguish True- from False-Positive Test Results
Eisenhofer, G., Goldstein, D. S., Walther, M. M., Friberg, P., Lenders, J. W. M., Keiser, H. R., & Pacak, K. (2003) · The Journal of Clinical Endocrinology & Metabolism · doi:10.1210/jc.2002-030005 · Cited by 492
Self-citationCardiac Sympathetic Nerve Function in Congestive Heart Failure
Eisenhofer, G., Friberg, P., Rundqvist, B., Quyyumi, A. A., Lambert, G., Kaye, D. M., Kopin, I. J., Goldstein, D. S., & Esler, M. D. (1996) · Circulation · doi:10.1161/01.cir.93.9.1667 · Cited by 453
Self-citationSubstantial Production of Dopamine in the Human Gastrointestinal Tract
Eisenhofer, G., Åneman, A., Friberg, P., Hooper, D., Fåndriks, L., Lonroth, H., Hunyady, B., & Mezey, E. (1997) · The Journal of Clinical Endocrinology & Metabolism · doi:10.1210/jcem.82.11.4339 · Cited by 394
Self-citationEisenhofer, G., Lenders, J. W. M., Linehan, W. M., Walther, M. M., Goldstein, D. S., & Keiser, H. R. (1999) · New England Journal of Medicine · doi:10.1056/nejm199906173402404 · Cited by 349
Self-citationEisenhofer, G., Lenders, J. W. M., Siegert, G., Bornstein, S. R., Friberg, P., Milosevic, D., Mannelli, M., Linehan, W. M., Adams, K., Timmers, H. J., et al. (2012) · European Journal of Cancer · doi:10.1016/j.ejca.2011.07.016 · Cited by 334
Self-citationBrouwers, F. M., Eisenhofer, G., Tao, J. J., Kant, J. A., Adams, K. T., Linehan, W. M., & Pacak, K. (2006) · The Journal of Clinical Endocrinology & Metabolism · doi:10.1210/jc.2006-0423 · Cited by 316
Self-citationAfter another decade: LC–MS/MS became routine in clinical diagnostics
Seger, C., & Salzmann, L. (2020) · Clinical Biochemistry · doi:10.1016/j.clinbiochem.2020.03.004 · Cited by 301
Eisenhofer, G., Lenders, J. W., Timmers, H., Mannelli, M., Grebe, S. K., Hofbauer, L. C., Bornstein, S. R., Tiebel, O., Adams, K., Bratslavsky, G., et al. (2011) · Clinical Chemistry · doi:10.1373/clinchem.2010.153320 · Cited by 290
Self-citationMeasurement of catecholamines and their metabolites
Peaston, R. T., & Weinkove, C. (2004) · Annals of Clinical Biochemistry: International Journal of Laboratory Medicine · doi:10.1258/000456304322664663 · Cited by 284
Timmers, H. J. L. M., Kozupa, A., Eisenhofer, G., Raygada, M., Adams, K. T., Solis, D., Lenders, J. W. M., & Pacak, K. (2007) · The Journal of Clinical Endocrinology & Metabolism · doi:10.1210/jc.2006-2315 · Cited by 276
Self-citationAdrenomedullary dysplasia and hypofunction in patients with classic 21-hydroxylase deficiency.
Merke, D. P., Chrousos, G. P., Eisenhofer, G., Weise, M., Keil, M. F., Rogol, A. D., Van Wyk, J. J., & Bornstein, S. R. (2000) · New England Journal of Medicine · doi:10.1056/nejm200011093431903 · Cited by 266
Self-citationThe Laboratory Diagnosis of Adrenal Pheochromocytoma: The Mayo Clinic Experience
Kudva, Y. C., Sawka, A. M., & Young, W. F. (2003) · The Journal of Clinical Endocrinology & Metabolism · doi:10.1210/jc.2003-030720 · Cited by 259
Eisenhofer, G., Keiser, H., Friberg, P., Mezey, E., Huynh, T.-T., Hiremagalur, B., Ellingson, T., Duddempudi, S., Eijsbouts, A., & Lenders, J. W. M. (1998) · The Journal of Clinical Endocrinology & Metabolism · doi:10.1210/jcem.83.6.4870 · Cited by 242
Self-citationDiagnostic Efficacy of Unconjugated Plasma Metanephrines for the Detection of Pheochromocytoma
Raber, W., Raffesberg, W., Bischof, M., Scheuba, C., Niederle, B., Gasic, S., Waldhäusl, W., & Roden, M. (2000) · Archives of Internal Medicine · doi:10.1001/archinte.160.19.2957 · Cited by 182
Charmandari, E., Weise, M., Bornstein, S. R., Eisenhofer, G., Keil, M. F., Chrousos, G. P., & Merke, D. P. (2002) · The Journal of Clinical Endocrinology & Metabolism · doi:10.1210/jcem.87.5.8456 · Cited by 164
“Plasma free metanephrine concentrations were determined using a different liquid chromatography procedure after extraction onto solid phase ion exchange columns (31).”
MethodSelf-citationEisenhofer, G., Friberg, P., Pacak, K., Goldstein, D. S., Murphy, D. L., Tsigos, C., Quyyumi, A. A., Brunner, H. G., & Lenders, J. W. M. (1995) · Clinical Science · doi:10.1042/cs0880533 · Cited by 123
Self-citationEisenhofer, G., Lattke, P., Herberg, M., Siegert, G., Qin, N., Därr, R., Hoyer, J., Villringer, A., Prejbisz, A., Januszewicz, A., et al. (2013) · Annals of Clinical Biochemistry International Journal of Laboratory Medicine · doi:10.1258/acb.2012.012066 · Cited by 113
Därr, R., Kuhn, M., Bode, C., Bornstein, S. R., Pacak, K., Lenders, J. W. M., & Eisenhofer, G. (2017) · Endocrine · doi:10.1007/s12020-017-1300-y · Cited by 105
Carvalho, V. M. (2012) · Journal of Chromatography B · doi:10.1016/j.jchromb.2011.08.027 · Cited by 90
Pubertal and gender-related changes in the sympathoadrenal system in healthy children.
Weise, M., Eisenhofer, G., & Merke, D. P. (2002) · The Journal of Clinical Endocrinology & Metabolism · doi:10.1210/jc.2002-020590 · Cited by 82
Self-citationAdrenomedullary function may predict phenotype and genotype in classic 21-hydroxylase deficiency
Charmandari, E., Eisenhofer, G., Mehlinger, S. L., Carlson, A., Wesley, R., Keil, M. F., Chrousos, G. P., New, M. I., & Merke, D. P. (2002) · The Journal of Clinical Endocrinology & Metabolism · doi:10.1210/jcem.87.7.8664 · Cited by 70
“Plasma total and free metanephrine concentrations were determined using a different liquid chromatography procedure after extraction onto solid phase ion exchange columns (23).”
MethodSelf-citationde Galan, B. E., Tack, C. J., Willemsen, J. J., Sweep, C. G. J. (., Smits, P., & Lenders, J. W. M. (2004) · The Journal of Clinical Endocrinology & Metabolism · doi:10.1210/jc.2003-031289 · Cited by 17
Self-citation
Metadata
- Authors
- Lenders, J. W., Eisenhofer, G., Armando, I., Keiser, H. R., Goldstein, D. S., & Kopin, I. J.
- Venue
- Clinical Chemistry
- Publisher
- Oxford University Press (OUP)
- Published
- 1993-01-01
- Volume
- 39
- Issue
- 1
- Pages
- 97-103
- ISSN
- 0009-9147 (ISSN-L)
- 1530-8561
- OpenAlex
- W2101065691
- Cited by
- 220
- References
- 0
- FWCI
- 3.86
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.