Enzyme immunoassay for intact human insulin in serum or plasma
The DOI matches its Crossref record; 13 of the 13 references it cites were found in a registry or an index.
Abstract
We describe an enzyme-linked two-site immunoassay for quantitation of intact insulin in human serum and plasma. The method uses two murine monoclonal antibodies that bind to two different epitopes on the insulin molecule. The immunoassay is specific. Human proinsulin is not bound by the antibodies, and the binding of partially processed proinsulin intermediates is believed to be of minor clinical importance. The relative response of human, bovine, and porcine insulin is 1, 1, and 3, respectively. The assay is sensitive (detection limit 5 pmol/L), accurate (101% recovery with 50 pmol/L insulin added to samples, 95% with 100 pmol/L, and 89% with 300 pmol/L), and fast (results within 3 h), and has a high analytical capacity (done in microtiter plates). The working assay range selected is 5-600 pmol/L, corresponding to a clinically useful range. Because of its specificity, this two-site immunoassay gives results that are lower than those obtained by using a competitive radioimmunoassay, both in normal individuals and in non-insulin-dependent diabetics.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Assay of Plasma Insulin in Human Subjects by Immunological Methods
YALOW, R. S., & BERSON, S. A. (1959) · Nature · doi:10.1038/1841648b0 · Cited by 1,098
Determination of total serum insulin (IRI) in insulin-treated diabetic patients
Heding, L. G. (1972) · Diabetologia · doi:10.1007/bf01225569 · Cited by 705
Sobey, W. J., Beer, S. F., Carrington, C. A., Clark, P. M. S., Frank, B. H., Gray, I. P., Luzio, S. D., Owens, D. R., Schneider, A. E., Siddle, K., et al. (1989) · Biochemical Journal · doi:10.1042/bj2600535 · Cited by 336
Heterophilic antibodies: a problem for all immunoassays.
Boscato, L. M., & Stuart, M. C. (1988) · Clinical Chemistry · doi:10.1093/clinchem/34.1.27 · Cited by 300
Labelled Antibodies and Immunological Assay Systems
MILES, L. E. M., & HALES, C. N. (1968) · Nature · doi:10.1038/219186a0 · Cited by 269
One-step sandwich enzyme immunoassay for insulin using monoclonal antibodies
Bürgi, W., Briner, M., Franken, N., & Kessler, A.-C. (1988) · Clinical Biochemistry · doi:10.1016/s0009-9120(88)80087-0 · Cited by 143
Hanning, I., Home, P. D., & Alberti, K. G. M. M. (1985) · Diabetologia · doi:10.1007/bf00291073 · Cited by 76
Highton, J., & Hessian, P. A. (1984) · Journal of Immunological Methods · doi:10.1016/0022-1759(84)90149-2 · Cited by 61
Two-site time-resolved immunofluorometric assay of human insulin.
Toivonen, E., Hemmilä, I. A., Marniemi, J., Jørgensen, P. N., Zeuthen, J., & Lövgren, T. N.-E. (1986) · Clinical Chemistry · doi:10.1093/clinchem/32.4.637 · Cited by 60
Self-citationEvidence for insulin degradation by muscle and fat tissue in an insulin resistant diabetic patient
MABERLY, G. F., Wait, G. A., Kilpatrick, J. A., Loten, E. G., Gain, K. R., Stewart, R. D. H., & Eastman, C. J. (1982) · Diabetologia · doi:10.1007/bf00253740 · Cited by 49
Stentz, F. B., Kitabchi, A. E., Schilling, J., Schronk, L. R., & Seyer, J. M. (1989) · Journal of Biological Chemistry · doi:10.1016/s0021-9258(19)47058-0 · Cited by 34
Evaluation of a solid-phase monoclonal antibody-based enzyme immunoassay for insulin in human serum
Storch, M.-J., Alexopoulos, A., & Kerp, L. (1989) · Journal of Immunological Methods · doi:10.1016/0022-1759(89)90380-3 · Cited by 12
Ingwersen, S. H., Jørgensen, P. N., Eiskjær, H., Johansen, N. L., Madsen, K., & Faarup, P. (1992) · Journal of Immunological Methods · doi:10.1016/0022-1759(92)90255-r · Cited by 11
Self-citation
Cited by
Interleukin-1-receptor antagonist in type 2 diabetes mellitus
Larsen, C. M., Faulenbach, M., Vaag, A., Vølund, A., Ehses, J. A., Seifert, B., Mandrup-Poulsen, T., & Donath, M. Y. (2007) · New England Journal of Medicine · doi:10.1056/nejmoa065213 · Cited by 1,798
Vessby, B., Uusitupa, M., Hermansen, K., Riccardi, G., Rivellese, A. A., Tapsell, L. C., Nälsén, C., Berglund, L., Louheranta, A., Rasmussen, B. M., et al. (2001) · Diabetologia · doi:10.1007/s001250051620 · Cited by 1,119
Tabák, A. G., Jokela, M., Akbaraly, T. N., Brunner, E. J., Kivimäki, M., & Witte, D. R. (2009) · The Lancet · doi:10.1016/s0140-6736(09)60619-x · Cited by 898
The Influence of GLP-1 on Glucose-Stimulated Insulin Secretion
Kjems, L. L., Holst, J. J., Vølund, A., & Madsbad, S. (2003) · Diabetes · doi:10.2337/diabetes.52.2.380 · Cited by 582
Gale, E. A. (2004) · The Lancet · doi:10.1016/s0140-6736(04)15786-3 · Cited by 534
Metadata
- Authors
- Andersen, L., Dinesen, B., Jørgensen, P. N., Poulsen, F., & Røder, M. E.
- Venue
- Clinical Chemistry
- Publisher
- Oxford University Press (OUP)
- Published
- 1993-04-01
- Volume
- 39
- Issue
- 4
- Pages
- 578-582
- ISSN
- 0009-9147 (ISSN-L)
- 1530-8561
- OpenAlex
- W2150121392
- Cited by
- 520
- References
- 13
- FWCI
- 7.08
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.