CoChat

Tolerance limits for short-term analytical bias and analytical imprecision derived from clinical assay specificity

Klee, G G · 1993 · Clinical Chemistry
Cited by 40

The DOI matches its Crossref record.

Abstract

I propose a method for defining tolerance limits for assay bias and assay imprecision, based on the effects of these tolerance limits on the clinical specificity of the assay. An analytical "error budget" is defined as the squared sums of the imprecision and bias errors. The maximum limit for this error budget is set at a value corresponding to a 50% increase in the false-positive rate for classifying healthy subjects. For gaussian distributions with +/- 2 SD used as decision limits, this error budget equates to 0.45 SD of combined within-person and between-person biological variation (SDBiol). To provide reasonable power for bias detection in an assay, I recommend that the SD of the assay be kept at less than half the bias limit. Then, for the gaussian distribution, the maximum bias limit should be < 0.36 SDBiol and the SD of the assay should be < 0.18 SDBiol. Procedures are provided for using the same principles to define tolerance limits for decision limits other than +/- 2 SD and for nongaussian distributions.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1093/clinchem/39.7.1514

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

Metadata

Authors
Klee, G. G.
Venue
Clinical Chemistry
Published
1993-07-01
Volume
39
Issue
7
Pages
1514-1518
ISSN
  • 0009-9147 (ISSN-L)
  • 1530-8561
OpenAlex
W2116056919
Cited by
40
References
0
FWCI
1.04
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.