Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 197

The DOI matches its Crossref record.

Plasma amino acids determined by liquid chromatography within 17 minutes

Terrlink, T, van Leeuwen, P A, Houdijk, A·1994·Clinical Chemistry

Abstract

We present an HPLC method for the determination of amino acids in plasma. The method is based on automated precolumn derivatization of amino acids with o-phthalaldehyde, separation of the derivatives by reversed-phase chromatography, and quantification by fluorescence detection. Complete separation was achieved within 12 min. Total analysis time, including derivatization, chromatography, and reequilibration of the column, was 17 min. The assay was linear from 5 to 800 mumol/L for all amino acids. Recovery of amino acids added to plasma samples was 96-106%, except for tryptophan (89%). Within-run precision (CV) was 1.8-6.4%, and between-run precision was 2.1-7.2%. The method can be used for determining primary amino acids in plasma and cerebrospinal fluid. The simple sample preparation and short analysis time make the method particularly suitable for routine analysis of large series of samples.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1093/clinchem/40.2.245

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 197

Metadata

Authors
Terrlink, T., van Leeuwen, P. A., & Houdijk, A.
Venue
Clinical Chemistry
Published
1994-02-01
Volume
40
Issue
2
Pages
245-249
ISSN
  • 0009-9147 (ISSN-L)
  • 1530-8561
OpenAlex
W1908510719
Cited by
197
References
0
FWCI
3.17
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Plasma amino acids determined by liquid chromatography within 17 minutes. https://app.cochat.ai/papers/10.1093/clinchem/40.2.245
The paper
Terrlink, T., van Leeuwen, P. A., & Houdijk, A. (1994). Plasma amino acids determined by liquid chromatography within 17 minutes. Clinical Chemistry. https://doi.org/10.1093/clinchem/40.2.245

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.