The DOI matches its Crossref record.
Ultrasensitive detection of prostate-specific antigen by a time-resolved immunofluorometric assay and the Immulite immunochemiluminescent third-generation assay: potential applications in prostate and breast cancers
Abstract
We report an ultrasensitive time-resolved immunofluorometric assay (TRIFA) for prostate-specific antigen (PSA). The assay is an improvement of our previous report (Clin Chem 1993;39:2108-14) and includes the utilization of two monoclonal antibodies and a one-step incubation period, which greatly reduces analysis time. The new method demonstrates a superior lower analytical limit of detection (< or = 1 ng/L), a wide dynamic range, absence of a hook effect at 10(6) ng/L PSA, and equimolarity for free PSA and PSA-antichymotrypsin complex. Also, we have compared several aspects of our TRIFA with a commercially available third-generation assay (Immulite). An evaluation of breast tumor cytosol extracts from 315 patients shows PSA immunoreactivity > 15 ng/g of total protein in 28% and 23% by TRIFA and Immulite analysis, respectively. Both methods demonstrate a significant association between breast tumor PSA immunoreactivity and progesterone and estrogen receptor positivity (P <0.001). Analysis of serum samples obtained for monitoring of postradical prostatectomy patients reveals significant PSA changes at concentrations undetectable by conventional methods. The significance of these results as well as the potential applications of ultrasensitive PSA assays in breast and prostate cancers are discussed.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Nanoparticle-Based Bio-Bar Codes for the Ultrasensitive Detection of Proteins
Nam, J.-M., Thaxton, C. S., & Mirkin, C. A. (2003) · Science · doi:10.1126/science.1088755 · Cited by 2,390
Rissin, D. M., Kan, C. W., Campbell, T. G., Howes, S. C., Fournier, D. R., Song, L., Piech, T., Patel, P. P., Chang, L., Rivnak, A. J., et al. (2010) · Nature Biotechnology · doi:10.1038/nbt.1641 · Cited by 2,119
The New Human Tissue Kallikrein Gene Family: Structure, Function, and Association to Disease*
Yousef, G. M., & Diamandis, E. P. (2001) · Endocrine Reviews · doi:10.1210/edrv.22.2.0424 · Cited by 675
Self-citationGold nanoparticle probes for the detection of nucleic acid targets
Thaxton, C. S., Georganopoulou, D. G., & Mirkin, C. A. (2006) · Clinica Chimica Acta · doi:10.1016/j.cccn.2005.05.042 · Cited by 368
Rittenhouse, H. G., Finlay, J. A., Mikolajczyk, S. D., & Partin, A. W. (1998) · Critical Reviews in Clinical Laboratory Sciences · doi:10.1080/10408369891234219 · Cited by 303
Metadata
- Authors
- Ferguson, R. A., Yu, H., Kalyvas, M., Zammit, S., & Diamandis, E. P.
- Venue
- Clinical Chemistry
- Publisher
- Oxford University Press (OUP)
- Published
- 1996-05-01
- Volume
- 42
- Issue
- 5
- Pages
- 675-684
- ISSN
- 0009-9147 (ISSN-L)
- 1530-8561
- OpenAlex
- W1937480514
- Cited by
- 169
- References
- 0
- FWCI
- 19.87
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Ultrasensitive detection of prostate-specific antigen by a time-resolved immunofluorometric assay and the Immulite immunochemiluminescent third-generation assay: potential applications in prostate and breast cancers. https://app.cochat.ai/papers/10.1093/clinchem/42.5.675
- The paper
- Ferguson, R. A., Yu, H., Kalyvas, M., Zammit, S., & Diamandis, E. P. (1996). Ultrasensitive detection of prostate-specific antigen by a time-resolved immunofluorometric assay and the Immulite immunochemiluminescent third-generation assay: potential applications in prostate and breast cancers. Clinical Chemistry. https://doi.org/10.1093/clinchem/42.5.675
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.