Luminescent oxygen channeling assay (LOCI): sensitive, broadly applicable homogeneous immunoassay method
The DOI matches its Crossref record.
Abstract
Luminescent oxygen channeling assay (LOCI) is a homogeneous immunoassay method capable of rapid, quantitative determination of a wide range of analytes--including high and very low concentrations of large and small molecules, free (unbound) drugs, DNA, and specific IgM. Assays have been carried out in serum and in lysed blood. Reliable detection of 1.25 microU/L thyrotropin (TSH) and 5 ng/L hepatitis B surface antigen (HBsAg) corresponds to detection limits approximately 3- and approximately 20-fold lower, respectively, than those of the best commercially available assays. An assay of chorionic gonadotropin is capable of quantification over a 10(6)-fold range of concentrations without a biphasic response. Latex particle pairs are formed in the assay through specific binding interactions by sequentially combining the sample and two reagents. One particle contains a photosensitizer, the other a chemiluminescer. Irradiation causes photosensitized formation of singlet oxygen, which migrates to a bound particle and activates the chemiluminescer, thereby initiating a delayed luminescence emission. Assay times range from 1 to 25 min.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Current approaches in SELEX: An update to aptamer selection technology
Darmostuk, M., Rimpelova, S., Gbelcova, H., & Ruml, T. (2015) · Biotechnology Advances · doi:10.1016/j.biotechadv.2015.02.008 · Cited by 702
Luminol-Based Chemiluminescent Signals: Clinical and Non-clinical Application and Future Uses
Khan, P., Idrees, D., Moxley, M. A., Corbett, J. A., Ahmad, F., von Figura, G., Sly, W. S., Waheed, A., & Hassan, M. I. (2014) · Applied Biochemistry and Biotechnology · doi:10.1007/s12010-014-0850-1 · Cited by 295
Point-of-care immunotesting: Approaching the analytical performance of central laboratory methods
von Lode, P. (2005) · Clinical Biochemistry · doi:10.1016/j.clinbiochem.2005.03.008 · Cited by 290
The Use of AlphaScreen Technology in HTS: Current Status
Eglen, R. M., Reisine, T., Roby, P., Rouleau, N., Illy, C., Bossé, R., & Bielefeld, M. (2008) · Current Chemical Genomics · doi:10.2174/1875397300801010002 · Cited by 260
SOCS2 negatively regulates growth hormone action in vitro and in vivo
Greenhalgh, C. J., Rico-Bautista, E., Lorentzon, M., Thaus, A. L., Morgan, P. O., Willson, T. A., Zervoudakis, P., Metcalf, D., Street, I., Nicola, N. A., et al. (2005) · Journal of Clinical Investigation · doi:10.1172/jci200522710 · Cited by 258
Clinical applications of chemiluminescence
Kricka, L. J. (2003) · Analytica Chimica Acta · doi:10.1016/s0003-2670(03)00809-2 · Cited by 243
Receptor–ligand binding assays: Technologies and Applications
de Jong, L. A. A., Uges, D. R. A., Franke, J. P., & Bischoff, R. (2005) · Journal of Chromatography B · doi:10.1016/j.jchromb.2005.10.002 · Cited by 205
Venomics: a new paradigm for natural products-based drug discovery
Vetter, I., Davis, J. L., Rash, L. D., Anangi, R., Mobli, M., Alewood, P. F., Lewis, R. J., & King, G. F. (2011) · Amino Acids · doi:10.1007/s00726-010-0516-4 · Cited by 197
Current status of modern analytical luminescence methods
Kulmala, S., & Suomi, J. (2003) · Analytica Chimica Acta · doi:10.1016/j.aca.2003.09.004 · Cited by 162
ROR nuclear receptors: Structures, related diseases, and drug discovery
Zhang, Y., Luo, X.-Y., Wu, D.-H., & Xu, Y. (2015) · Acta Pharmacologica Sinica · doi:10.1038/aps.2014.120 · Cited by 151
Ungermannova, D., Lee, J., Zhang, G., Dallmann, H. G., McHenry, C. S., & Liu, X. (2013) · SLAS Discovery · doi:10.1177/1087057113485789 · Cited by 70
Biester, T., Blaesig, S., Remus, K., Aschemeier, B., Kordonouri, O., Granhall, C., Søndergaard, F., Kristensen, N. R., Haahr, H., & Danne, T. (2014) · Pediatric Diabetes · doi:10.1111/pedi.12116 · Cited by 53
“Serum IDeg concentration was measured using a validated IDeg-specific sandwich enzyme-linked immunosorbent assay (ELISA), whereas serum IGlar concentration was measured using a validated IGlarspecific luminescent oxygen channelling immunoassay (LOCI) (18).”
MethodSOCS3 negatively regulates LIF signaling in neural precursor cells
Emery, B., Merson, T. D., Snell, C., Young, K. M., Ernst, M., & Kilpatrick, T. J. (2006) · Molecular and Cellular Neuroscience · doi:10.1016/j.mcn.2006.01.005 · Cited by 29
Metadata
- Authors
- Ullman, E. F., Kirakossian, H., Switchenko, A. C., Ishkanian, J., Ericson, M., Wartchow, C. A., Pirio, M., Pease, J., Irvin, B. R., Singh, S., Singh, R., Patel, R., Dafforn, A., Davalian, D., Skold, C., Kurn, N., & Wagner, D. B.
- Venue
- Clinical Chemistry
- Publisher
- Oxford University Press (OUP)
- Published
- 1996-09-01
- Volume
- 42
- Issue
- 9
- Pages
- 1518-1526
- ISSN
- 0009-9147 (ISSN-L)
- 1530-8561
- OpenAlex
- W1936218468
- Cited by
- 256
- References
- 0
- FWCI
- 0.37
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.