Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 331

The DOI matches its Crossref record.

Real-time fluorescence genotyping of factor V Leiden during rapid-cycle PCR

Lay, Marla J, Wittwer, Carl T·1997·Clinical Chemistry

Abstract

A single-step method for factor V Leiden genotyping is presented that uses rapid-cycle PCR and simultaneous fluorescence analysis with resonance energy transfer probes. A fragment of the factor V gene containing the mutation is amplified asymmetrically through use of a primer labeled with Cy5TM in the presence of a 3′-fluorescein-labeled probe that covers the mutation site. When the fluorescein probe is annealed to the extension product of the Cy5-labeled primer, the fluorophores are brought into close enough contact for resonance energy transfer to occur. As the temperature increases, the probe melts from its target, decreasing the resonance energy transfer. When the probe is complementary to the product strand, it melts at 65 °C; if the single-base mutation is present, the probe melts at 57 °C. Concurrent amplification and analysis from genomic DNA takes 20–45 min and requires no sample manipulation after the fluorescence thermal cycler is loaded.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1093/clinchem/43.12.2262

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 331

Metadata

Authors
Lay, M. J., & Wittwer, C. T.
Venue
Clinical Chemistry
Published
1997-12-01
Volume
43
Issue
12
Pages
2262-2267
ISSN
  • 0009-9147 (ISSN-L)
  • 1530-8561
OpenAlex
W2113001043
Cited by
331
References
0
FWCI
7.41
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Real-time fluorescence genotyping of factor V Leiden during rapid-cycle PCR. https://app.cochat.ai/papers/10.1093/clinchem/43.12.2262
The paper
Lay, M. J., & Wittwer, C. T. (1997). Real-time fluorescence genotyping of factor V Leiden during rapid-cycle PCR. Clinical Chemistry. https://doi.org/10.1093/clinchem/43.12.2262

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.