Advanced multiplexed analysis with the FlowMetrixTM system
Abstract
The FlowMetrixTM System is a multiplexed data acquisition and analysis platform for flow cytometric analysis of microsphere-based assays that performs simultaneous measurement of up to 64 different analytes. The system consists of 64 distinct sets of fluorescent microspheres and a standard benchtop flow cytometer interfaced with a personal computer containing a digital signal processing board and Windows95®-based software. Individual sets of microspheres can be modified with reactive components such as antigens, antibodies, or oligonucleotides, and then mixed to form a multiplexed assay set. The digital signal-processing hardware and Windows95-based software provide complete control of the flow cytometer and perform real-time data processing, allowing multiple independent reactions to be analyzed simultaneously. The system has been used to perform qualitative and quantitative immunoassays for multiple serum proteins in both capture and competitive inhibition assay formats. The system has also been used to perform DNA sequence analysis by multiplexed competitive hybridization with 16 different sequence-specific oligonucleotide probes.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
HLA-DQβ gene contributes to susceptibility and resistance to insulin-dependent diabetes mellitus
Todd, J. A., Bell, J. I., & McDevitt, H. O. (1987) · Nature · doi:10.1038/329599a0 · Cited by 2,036
Wood, W. I., Gitschier, J., Lasky, L. A., & Lawn, R. M. (1985) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.82.6.1585 · Cited by 790
Wallace, R. B., Shaffer, J., Murphy, R. F., Bonner, J., Hirose, T., & Itakura, K. (1979) · Nucleic Acids Research · doi:10.1093/nar/6.11.3543 · Cited by 748
Detection of sickle cell beta S-globin allele by hybridization with synthetic oligonucleotides.
Conner, B. J., Reyes, A. A., Morin, C., Itakura, K., Teplitz, R. L., & Wallace, R. B. (1983) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.80.1.278 · Cited by 531
Quantitative Single Cell Analysis and Sorting
Horan, P. K., & Wheeless, L. L. (1977) · Science · doi:10.1126/science.905822 · Cited by 347
A dot-blot screening procedure for mutated ras oncogenes using synthetic oligodeoxynucleotides
Verlaan-de Vries, M., Bogaard, M. E., van den Elst, H., van Boom, J. H., van der Eb, A. J., & Bos, J. L. (1986) · Gene · doi:10.1016/0378-1119(86)90335-5 · Cited by 336
Bos, J. L., Vries, M. V.-D., Jansen, A. M., Veeneman, G. H., van Boom, J. H., & van der Eb, A. J. (1984) · Nucleic Acids Research · doi:10.1093/nar/12.23.9155 · Cited by 164
Jacobs, K. A., Rudersdorf, R. A., Neill, S. D., et al. (1988) · Nucleic Acids Research · doi:10.1093/nar/16.10.4637 · Cited by 119
McHugh, T. M., Miner, R. C., Logan, L. H., & Stites, D. P. (1988) · Journal of Clinical Microbiology · doi:10.1128/jcm.26.10.1957-1961.1988 · Cited by 67
Early detection of antibodies against rDNA-produced HIV proteins with a flow cytometric assay
Scillian, J., McHugh, T. M., Busch, M. P., Tam, M., Fulwyler, M. J., Chien, D., & Vyas, G. (1989) · Blood · doi:10.1182/blood.v73.7.2041.2041 · Cited by 53
Cited by
Allergy Diagnostic Testing: An Updated Practice Parameter
Bernstein, I. L., Li, J. T., Bernstein, D. I., Hamilton, R., Spector, S. L., Tan, R., Sicherer, S., Golden, D. B. K., Khan, D. A., Nicklas, R. A., et al. (2008) · Annals of Allergy, Asthma & Immunology · doi:10.1016/s1081-1206(10)60305-5 · Cited by 723
Zunder, E. R., Finck, R., Behbehani, G. K., Amir, E.-A. D., Krishnaswamy, S., Gonzalez, V. D., Lorang, C. G., Bjornson, Z., Spitzer, M. H., Bodenmiller, B., et al. (2015) · Nature Protocols · doi:10.1038/nprot.2015.020 · Cited by 596
Dunbar, S. A. (2006) · Clinica Chimica Acta · doi:10.1016/j.cccn.2005.06.023 · Cited by 608
Multiplexed detection of pathogen DNA with DNA-based fluorescence nanobarcodes
Li, Y., Cu, Y. T. H., & Luo, D. (2005) · Nature Biotechnology · doi:10.1038/nbt1106 · Cited by 517
Ansotegui, I. J., Melioli, G., Canonica, G. W., Caraballo, L., Villa, E., Ebisawa, M., Passalacqua, G., Savi, E., Ebo, D., Gómez, R. M., et al. (2020) · World Allergy Organization Journal · doi:10.1016/j.waojou.2019.100080 · Cited by 489
Metadata
- Authors
- Fulton, R. J., McDade, R. L., Smith, P. L., Kienker, L. J., & Kettman, J. R.
- Venue
- Clinical Chemistry
- Publisher
- Oxford University Press (OUP)
- Published
- 1997-09-01
- Volume
- 43
- Issue
- 9
- Pages
- 1749-1756
- ISSN
- 0009-9147 (ISSN-L)
- 1530-8561
- OpenAlex
- W4297632218
- Cited by
- 650
- References
- 10
- FWCI
- 5.63
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Advanced multiplexed analysis with the FlowMetrixTM system. https://app.cochat.ai/papers/10.1093/clinchem/43.9.1749
- The paper
- Fulton, R. J., McDade, R. L., Smith, P. L., Kienker, L. J., & Kettman, J. R. (1997). Advanced multiplexed analysis with the FlowMetrixTM system. Clinical Chemistry. https://doi.org/10.1093/clinchem/43.9.1749
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.