CoChat

Evaluation of an immunoseparation method for quantitative measurement of remnant-like particle-cholesterol in serum and plasma

Leary, Elizabeth Teng, Wang, Tao, Baker, Daniel J, Cilla, Donald D, Zhong, Jianhua, Warnick, G Russell, Nakajima, Katsuyuki, Havel, Richard J · 1998 · Clinical Chemistry
Cited by 110

The DOI matches its Crossref record; 5 of the 5 references it cites were found in a registry or an index.

Abstract

Substantial evidence indicates that triglyceride-rich lipoprotein remnants are atherogenic. Additional research has, however, been limited by available methods for separation and quantification of remnants. We have evaluated an immunoseparation assay developed to measure cholesterol in remnant-like particles (RLP-C). This method uses monoclonal antibodies to human apolipoproteins B-100 and A-I to remove most of the apolipoprotein B-100-containing lipoproteins (namely LDL and nascent VLDL) and apolipoprotein A-I-containing lipoproteins (namely chylomicrons and HDL), leaving behind a fraction of triglyceride-rich lipoproteins, including chylomicron and VLDL remnants, both of which are enriched in apolipoprotein E. Cholesterol in the unbound fraction is measured with a sensitive enzymatic assay. The RLP-C concentration was highly correlated with total triglyceride-rich lipoproteins (sum of VLDL-cholesterol and IDL-cholesterol) separated by ultracentrifugation and by polyacrylamide gel electrophoresis (r = 0.86 and 0.76, respectively). The within-run and run-to-run imprecision (CV) of the assay was ∼6% and 10%, respectively. The assay was not affected by hemoglobin up to 5000 mg/L (500 mg/dL), bilirubin up to 342 mmol/L (20 mg/dL), glucose up to 67 mmol/L (1200 mg/dL), or ascorbic acid up to 170 mmol/L (3.0 mg/dL). In 726 subjects (men, n = 364; women, n = 362) in the US, the 75th percentiles of RLP-C concentration were 0.17 mmol/L (6.6 mg/dL) and 0.23 mmol/L (8.8 mg/dL) in sera obtained after overnight fasting or randomly, respectively. A group of 151 patients from nine US centers and one Canadian center with coronary artery atherosclerosis established by angiography had higher median RLP-C concentrations than 302 gender- and age-matched controls (P <0.05). We conclude that the RLP-C assay compares favorably to ultracentrifugation and electrophoresis and provides a convenient and economical approach to measure triglyceride-rich lipoprotein remnants in routine clinical laboratories.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1093/clinchem/44.12.2490

Cites

5 of 5 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 5 references

Cited by

See all 110

Metadata

Authors
Leary, E. T., Wang, T., Baker, D. J., Cilla, D. D., Zhong, J., Warnick, G. R., Nakajima, K., & Havel, R. J.
Venue
Clinical Chemistry
Published
1998-12-01
Volume
44
Issue
12
Pages
2490-2498
ISSN
  • 0009-9147 (ISSN-L)
  • 1530-8561
OpenAlex
W2131237038
Cited by
110
References
5
FWCI
11.47
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Evaluation of an immunoseparation method for quantitative measurement of remnant-like particle-cholesterol in serum and plasma. https://app.cochat.ai/papers/10.1093/clinchem/44.12.2490
The paper
Leary, E. T., Wang, T., Baker, D. J., Cilla, D. D., Zhong, J., Warnick, G. R., Nakajima, K., & Havel, R. J. (1998). Evaluation of an immunoseparation method for quantitative measurement of remnant-like particle-cholesterol in serum and plasma. Clinical Chemistry. https://doi.org/10.1093/clinchem/44.12.2490

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.