Rapid Automated High Sensitivity Enzyme Immunoassay of C-Reactive Protein
The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Abstract
The concentration of C-reactive protein (CRP), the classic acute phase plasma protein, increases rapidly in response to most forms of tissue injury, infection, and inflammation (1)(2)(3). CRP is secreted only by hepatocytes, where its synthesis is regulated by cytokines, of which IL-6 is the most important. The t1/2 of CRP in the circulation (∼19 h) is independent of the plasma concentration and is remarkably constant in all conditions (4). Thus, the only determinant of the plasma concentration is the rate of CRP production, which usually reflects closely the extent and activity of the current pathology. Furthermore, the CRP response is very sensitive, and although it is nonspecific and can never on its own be diagnostic, it provides an extremely useful objective marker in clinical practice, both in screening for organic disease and in monitoring disease activity and response to therapy (3). CRP concentrations in ostensibly healthy subjects have a very skewed distribution. In the first study with a sufficiently sensitive radioimmunoassay to detect CRP in all nondiseased sera tested, the median value was 0.58 mg/L (range, 0.068–8.2 mg/L) among 153 healthy blood donors (5). In our own original study of 468 volunteer blood donors, using the same 100% pure CRP as standard that was subsequently used to calibrate the World Health Organization International Standard for Human CRP (85/506) (6), the median value was 0.8 mg/L, and there was a tail of higher values, with the 90th percentile at 3 mg/L and the 99th percentile at 10 mg/L (7). In a more recent study based on the WHO standard and examining 143 apparently healthy blood donors, the median CRP value was 0.64 mg/L, and the 97.5th percentile was 3.11 mg/L (8). Routinely available immunochemical assay methods for plasma proteins have limited sensitivity, and until recently, CRP concentrations below ∼10 mg/L could not be measured precisely, leading to widespread adoption of this value, or even higher, as the upper limit of the health-associated reference range. This is satisfactory for some purposes in general medicine because the marked acute phase responses that characterize bacterial infections, ischemic necrosis of tissue, and most active inflammatory conditions usually lead to much greater CRP values, sometimes reaching hundreds of milligrams per liter. However, in neonatal pediatric practice, a high-sensitivity CRP immunoassay shows that health-associated reference values are below 1–2 mg/L and that any rise above such values is associated with serious disease, usually bacterial infection (9). More recently, application of sensitive CRP assays to studies of adult cardiovascular disease has revealed important prognostic relationships between modest increases of CRP and the occurrence, progression, and thrombo-occlusive complications of atherosclerosis. This was first demonstrated, using the present assay, in patients admitted to hospital with severe unstable angina (10) and in the European Concerted Action on Thrombosis and Disabilities (ECAT) Angina Pectoris Study (11)(12). Our findings have subsequently been widely confirmed and extended (13)(14)(15)(16)(17)(18). Remarkably, the association extends even to apparently healthy asymptomatic individuals. These observations clearly have profound implications for risk assessment, for prophylaxis, and for routine clinical management of coronary heart disease. They also open new avenues for exploration of the pathogenesis of atheroma and its complications. The present high-sensitivity automated enzyme immunoassay for CRP was developed specifically to measure the large number of samples in the ECAT study (11)(12). It has also been used for research in osteoarthritis (19) and neonatal infection, as well as for other coronary heart disease studies (20)(21). The speed and flexibility of the immunoassay should facilitate additional research and also the practical clinical applications of these important new findings. CRP was isolated and purified as previously described (4), and 100% pure material, used as the reference analyte, was standardized on the WHO Standard (85/506) (6) (prepared at the Royal Postgraduate Medical School and available from the National Institute for Biological Standards and Control, Herts EN6 3QG, UK). Mouse monoclonal anti-CRP antibodies were raised against the 100% pure CRP; 95% pure CRP, diluted in Tris buffer, pH 7.5, with stabilizers and preservatives, was used for calibrators and controls. The IMxTM (Abbott Laboratories) (22) CRP research assay is an automated microparticle capture enzyme immunoassay (MEIA). Two mouse anti-CRP monoclonal antibodies (Abbott Laboratories) were used, one immobilized on microparticles (Seradyn, Indianapolis, IN), the other conjugated to alkaline phosphatase (23). The IMx carousel containing 24 reaction cells was loaded with 20 samples consisting of sera diluted 1:50 with MEIA buffer. A zero blank and three controls containing low, medium, and high concentratio
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Serological reactions in pneumonia with a non-protein somatic fraction of Pneumococcus
Tillett, W. S., & Francis, T. (1930) · Journal of Experimental Medicine · doi:10.1084/jem.52.4.561 · Cited by 1,482
Spector, T. D., Hart, D. J., Nandra, D., Doyle, D. V., Mackillop, N., Gallimore, J. R., & Pepys, M. B. (1997) · Arthritis & Rheumatism · doi:10.1002/art.1780400419 · Cited by 403 · cited 2×
“It has also been used for research in osteoarthritis (19) and neonatal infection, as well as for other coronary heart disease studies (20, 21).”
BackgroundSelf-citation
Cited by
Koenig, W., Sund, M., Fröhlich, M., Fischer, H.-G., Löwel, H., Döring, A., Hutchinson, W. L., & Pepys, M. B. (1999) · Circulation · doi:10.1161/01.cir.99.2.237 · Cited by 1,964
Self-citationLow grade inflammation and coronary heart disease: prospective study and updated meta-analyses
Danesh, J. (2000) · BMJ · doi:10.1136/bmj.321.7255.199 · Cited by 1,692
Ridker, P. M., Buring, J. E., Shih, J., Matias, M., & Hennekens, C. H. (1998) · Circulation · doi:10.1161/01.cir.98.8.731 · Cited by 1,642
Electrochemical Methods for the Analysis of Clinically Relevant Biomolecules
Labib, M., Sargent, E. H., & Kelley, S. O. (2016) · Chemical Reviews · doi:10.1021/acs.chemrev.6b00220 · Cited by 976
Roberts, W. L., Moulton, L., Law, T. C., Farrow, G., Cooper-Anderson, M., Savory, J., & Rifai, N. (2001) · Clinical Chemistry · doi:10.1093/clinchem/47.3.418 · Cited by 652
Metadata
- Authors
- Wilkins, J., Gallimore, J. R., Moore, E. G., & Pepys, M. B.
- Venue
- Clinical Chemistry
- Publisher
- Oxford University Press (OUP)
- Published
- 1998-06-01
- Volume
- 44
- Issue
- 6
- Pages
- 1358-1361
- ISSN
- 0009-9147 (ISSN-L)
- 1530-8561
- OpenAlex
- W1951306029
- Cited by
- 126
- References
- 2
- FWCI
- 2.75
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.