CoChat

Analytical performance and clinical application of a new rapid bedside assay for the detection of serum cardiac troponin I

Heeschen, Christopher, Goldmann, Britta U, Moeller, Robert H, Hamm, Christian W · 1998 · Clinical Chemistry
Cited by 71

The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.

Abstract

Detection of cardiac troponin I (cTnI) in patients suspected of having an acute coronary syndrome is highly predictive for an adverse outcome. We evaluated a bedside test for cTnI that uses a polyclonal capture antibody and two monoclonal indicator antibodies. Clinical studies were performed in patients with acute coronary syndrome and patients with chest pain but no evidence of acute myocardial injury. The whole-blood, 15-minute assay had a concordance of 98.9% with an ELISA for cTnI and a detection limit of 0.14 μg/L, and the device tolerated temperatures between 4 °C and 37 °C. Diagnostic sensitivity for myocardial infarction at arrival (3.5 ± 2.7 h after onset of symptoms) was 60% [creatine kinase isoenzyme MB (CK-MB) mass, 48%; CK activity, 36%; P < 0.01], and 4 h later, diagnostic sensitivity was 98% (CK-MB mass, 91%; CK activity, 61%; P < 0.01). In 38% of the patients with unstable angina, at least one positive cTnI test was found (CK-MB mass, 4%; CK activity, 2%). No false-positive test results were found in renal failure or injury of skeletal muscle. We conclude that the diagnostic efficacy of the cTnI rapid test was comparable with the cTnI ELISA and superior to CK-MB determination. Therefore, this device could facilitate decision-making in patients with chest pain at the point of care.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1093/clinchem/44.9.1925

Cites

2 of 2 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 2 references

Cited by

See all 71

Metadata

Authors
Heeschen, C., Goldmann, B. U., Moeller, R. H., & Hamm, C. W.
Venue
Clinical Chemistry
Published
1998-09-01
Volume
44
Issue
9
Pages
1925-1930
ISSN
  • 0009-9147 (ISSN-L)
  • 1530-8561
OpenAlex
W2169767764
Cited by
71
References
2
FWCI
5.69
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Analytical performance and clinical application of a new rapid bedside assay for the detection of serum cardiac troponin I. https://app.cochat.ai/papers/10.1093/clinchem/44.9.1925
The paper
Heeschen, C., Goldmann, B. U., Moeller, R. H., & Hamm, C. W. (1998). Analytical performance and clinical application of a new rapid bedside assay for the detection of serum cardiac troponin I. Clinical Chemistry. https://doi.org/10.1093/clinchem/44.9.1925

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.