Analytical performance and clinical application of a new rapid bedside assay for the detection of serum cardiac troponin I
The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Abstract
Detection of cardiac troponin I (cTnI) in patients suspected of having an acute coronary syndrome is highly predictive for an adverse outcome. We evaluated a bedside test for cTnI that uses a polyclonal capture antibody and two monoclonal indicator antibodies. Clinical studies were performed in patients with acute coronary syndrome and patients with chest pain but no evidence of acute myocardial injury. The whole-blood, 15-minute assay had a concordance of 98.9% with an ELISA for cTnI and a detection limit of 0.14 μg/L, and the device tolerated temperatures between 4 °C and 37 °C. Diagnostic sensitivity for myocardial infarction at arrival (3.5 ± 2.7 h after onset of symptoms) was 60% [creatine kinase isoenzyme MB (CK-MB) mass, 48%; CK activity, 36%; P < 0.01], and 4 h later, diagnostic sensitivity was 98% (CK-MB mass, 91%; CK activity, 61%; P < 0.01). In 38% of the patients with unstable angina, at least one positive cTnI test was found (CK-MB mass, 4%; CK activity, 2%). No false-positive test results were found in renal failure or injury of skeletal muscle. We conclude that the diagnostic efficacy of the cTnI rapid test was comparable with the cTnI ELISA and superior to CK-MB determination. Therefore, this device could facilitate decision-making in patients with chest pain at the point of care.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Antman, E. M., Tanasijevic, M. J., Thompson, B., Schactman, M., McCabe, C. H., Cannon, C. P., Fischer, G. A., Fung, A. Y., Thompson, C., Wybenga, D., et al. (1996) · New England Journal of Medicine · doi:10.1056/nejm199610313351802 · Cited by 1,749
Katrukha, A. G., Bereznikova, A. V., Esakova, T. V., Pettersson, K., Lövgren, T., Severina, M. E., Pulkki, K., Vuopio-Pulkki, L.-M., & Gusev, N. B. (1997) · Clinical Chemistry · doi:10.1093/clinchem/43.8.1379 · Cited by 266 · cited 1×
“The selected antibodies bind both free and complexed cTnI with high affinity (17, 22).”
Background
Cited by
A Classification of Unstable Angina Revisited
Hamm, C. W., & Braunwald, E. (2000) · Circulation · doi:10.1161/01.cir.102.1.118 · Cited by 394
Self-citationMeasurement of Cardiac Troponins
Collinson, P. O., Boa, F. G., & Gaze, D. C. (2001) · Annals of Clinical Biochemistry: International Journal of Laboratory Medicine · doi:10.1177/000456320103800501 · Cited by 275
Leitlinien: Akutes Koronarsyndrom (ACS)
Hamm, C. W. (2004) · Zeitschrift f�r Kardiologie · doi:10.1007/s00392-004-0109-x · Cited by 163
Self-citationGoodacre, S., Bradburn, M., Fitzgerald, P., Cross, E., Collinson, P., Gray, A., & Hall, A. (2011) · Health Technology Assessment · doi:10.3310/hta15230 · Cited by 64
Point-of-care testing: where is the evidence? A systematic survey
Pecoraro, V., Germagnoli, L., & Banfi, G. (2014) · Clinical Chemistry and Laboratory Medicine (CCLM) · doi:10.1515/cclm-2013-0386 · Cited by 56
A systematic evaluation of immunoassay point-of-care testing to define impact on patients’ outcomes
Pecoraro, V., Banfi, G., Germagnoli, L., & Trenti, T. (2017) · Annals of Clinical Biochemistry: International Journal of Laboratory Medicine · doi:10.1177/0004563217694377 · Cited by 17
“Thirteen studies reported data about the accuracy of POCT to identify myocardial infarction or acute coronary syndrome and the relevant concordance between POCT and laboratory results.(15,78,82,83,87,95,97,98,105,107,108,113,117,118) Nine studies discussed the POCT usefulness on decisionmaking, concluding that a small…”
Background
Metadata
- Authors
- Heeschen, C., Goldmann, B. U., Moeller, R. H., & Hamm, C. W.
- Venue
- Clinical Chemistry
- Publisher
- Oxford University Press (OUP)
- Published
- 1998-09-01
- Volume
- 44
- Issue
- 9
- Pages
- 1925-1930
- ISSN
- 0009-9147 (ISSN-L)
- 1530-8561
- OpenAlex
- W2169767764
- Cited by
- 71
- References
- 2
- FWCI
- 5.69
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.