CoChat

A systematic evaluation of immunoassay point-of-care testing to define impact on patients’ outcomes

Pecoraro, Valentina, Banfi, Giuseppe, Germagnoli, Luca, Trenti, Tommaso · 2017 · Annals of Clinical Biochemistry: International Journal of Laboratory Medicine

The DOI matches its Crossref record; 131 of the 131 references it cites were found in a registry or an index.

Abstract

Background: Point-of-care testing has been developed to provide rapid test results. Most published studies focus on analytical performance, neglecting its impact on patient outcomes. Objective: To review the analytical performance and accuracy of point-of-care testing specifically planned for immunoassay and to evaluate the impact of faster results on patient management. Methods: A search of electronic databases for studies reporting immunoassay results obtained in both point-of-care testing and central laboratory scenarios was performed. Data were extracted concerning the study details, and the methodological quality was assessed. The analytical characteristics and diagnostic accuracy of six points-of-care testing: troponin, procalcitonin, parathyroid hormone, brain natriuretic peptide, C-reactive protein and neutrophil gelatinase-associated lipocalin were evaluated. Results: A total of 116 scientific papers were analysed. Studies measuring procalcitonin, parathyroid hormone and neutrophil gelatinase-associated lipocalin reported a limited impact on diagnostic decisions. Seven studies measuring C-reactive protein claimed a significant reduction of antibiotic prescription. Several authors evaluated brain natriuretic peptide or troponin reporting faster decision-making without any improvement in clinical outcome. Forty-four per cent of studies reported analytical data, showing satisfactory correlations between results obtained through point-of-care testing and central laboratory setting. Half of studies defined the diagnostic accuracy of point-of-care testing as acceptable for troponin (median sensitivity and specificity: 74% and 94%, respectively), brain natriuretic peptide (median sensitivity and specificity: 82% and 88%, respectively) and C-reactive protein (median sensitivity and specificity 85%). Conclusions: Point-of-care testing immunoassay results seem to be reliable and accurate for troponin, brain natriuretic peptide and C-reactive protein. The satisfactory analytical performance, together with an excellent practicability, suggests that it could be a consistent tool in clinical practice, but data are lacking regarding the patient outcomes.

Overview

Integrity signals

Registry

Crossref · 10.1177/0004563217694377

Cites

131 of 131 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Verification

Claims the paper makes

This paper’s full text isn’t openly available, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Citations

Cites

Show all 131 references

Research works printed but not linked: 11

  1. Del Ry S, 2001, Clin Chem Lab Med, 39, 446
  2. Di Somma S, 2015, Clin Chem Lab Med, 43, 507
  3. Jorgensen B, 2012, Clin Lab, 58, 515
  4. Prontera C, 2005, Clin Lab, 51, 1274
  5. Shah K, 2010, West J Emerg Med, 11, 44
  6. Vogeser M, 2001, Clin Lab, 47, 29
  7. 10.1067/mhj.2002.125623 · doi:10.1067/mhj.2002.125623 · Paper page
  8. Papa F, 2012, Clin Lab, 58, 951
  9. Goldmann BU, 2004, Clin Lab, 50, 1
  10. Loten C, 2009, EMA, 21, 286
  11. Monneret D, 2014, Clin Chem Lab Med, 52, e279

Cited by

See all 17

Metadata

Authors
Pecoraro, V., Banfi, G., Germagnoli, L., & Trenti, T.
Affiliations
  • Mario Negri Institute for Pharmacological Research (IT)
  • Vita-Salute San Raffaele University (IT)
  • Synlab Italia, Brescia, Italy
  • Department of Laboratory Medicine, Clinical Pathology-Toxicology, Ospedale Civile Sant’Agostino Estense, Modena, Italy
Corresponding author
Pecoraro, Valentina
Venue
Annals of Clinical Biochemistry: International Journal of Laboratory Medicine
Published
2017-05-15
Volume
54
Issue
4
Pages
420-431
ISSN
  • 0004-5632 (ISSN-L)
  • 1758-1001
OpenAlex
W2583469375
Cited by
17
References
130
Citations by year
2026: 1 · 2024: 3 · 2022: 1 · 2021: 3 · 2020: 4 · 2019: 2 · 2018: 2 · 2017: 1
FWCI
1.82
Type
journal article
Language
en
Open access
closed
Licence
journals.sagepub.com/page/policies/text-and-data-mining-license (tdm)
Locations
  • Annals of Clinical Biochemistry International Journal of Laboratory Medicine (publishedVersion)
  • PubMed (publishedVersion)
  • Archivio Istituzionale della Ricerca - Università Vita-Salute San Raffaele (submittedVersion)
Topics
  • Health Sciences › Health Professions › Medical Laboratory Technology › Clinical Laboratory Practices and Quality Control
  • Physical Sciences › Engineering › Biomedical Engineering › Biosensors and Analytical Detection
  • Health Sciences › Medicine › Microbiology (medical) › Bacterial Identification and Susceptibility Testing
Keywords
point-of-care testing, immunoassay, patient outcomes, diagnostic accuracy, analytical performance, troponin, brain natriuretic peptide, C-reactive protein, procalcitonin, parathyroid hormone, neutrophil gelatinase-associated lipocalin, antibiotic prescribing, central laboratory comparison, clinical decision-making
MeSH terms
Clinical Decision-Making, Point-of-Care Testing, Clinical Studies as Topic, Lipocalin-2, C-Reactive Protein, Calcitonin, Humans, Immunoassay, Laboratories, Hospital, Parathyroid Hormone, Sensitivity and Specificity, Troponin, Treatment Outcome, Natriuretic Peptide, Brain

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: A systematic evaluation of immunoassay point-of-care testing to define impact on patients’ outcomes. https://app.cochat.ai/papers/10.1177/0004563217694377
The paper
Pecoraro, V., Banfi, G., Germagnoli, L., & Trenti, T. (2017). A systematic evaluation of immunoassay point-of-care testing to define impact on patients’ outcomes. Annals of Clinical Biochemistry: International Journal of Laboratory Medicine. https://doi.org/10.1177/0004563217694377

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.