The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Ligand assays: from electrophoresis to miniaturized microarrays
Open accessAbstract
The main developments in the “ligand assay” field in which I have been involved are traced. These include the original development of “first generation” competitive assays relying on radiolabeled analyte markers; the development of the first “second generation”, noncompetitive (ultrasensitive) methods, which rely on the use of labeled (monoclonal) antibodies and high specific activity nonisotopic labels (leading to the transformation of the immunodiagnostic field in the 1980s); and the development of the first “third generation” miniaturized, chip-based, microarray methods, which permit the simultaneous ultrasensitive measurement of many analytes in the same small sample. The latter—applicable both to immunoassay and to DNA/RNA analysis—are likely to revolutionize the diagnostic and pharmaceutical fields in the next decade.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Immunoassay of endogenous plasma insulin in man
Yalow, R. S., & Berson, S. A. (1960) · Journal of Clinical Investigation · doi:10.1172/jci104130 · Cited by 3,041
DIAGNOSIS OF ALLERGY BY AN IN-VITRO TEST FOR ALLERGEN ANTIBODIES
Wide, L., Bennich, H., & Johansson, S. G. O. (1967) · The Lancet · doi:10.1016/s0140-6736(67)90615-0 · Cited by 1,253
Cited by
Nanostructures in Biodiagnostics
Rosi, N. L., & Mirkin, C. A. (2005) · Chemical Reviews · doi:10.1021/cr030067f · Cited by 4,603
EAACI Molecular Allergology User's Guide
Matricardi, P. M., Kleine‐Tebbe, J., Hoffmann, H. J., Valenta, R., Hilger, C., Hofmaier, S., Aalberse, R. C., Agache, I., Asero, R., Ballmer‐Weber, B., et al. (2016) · Pediatric Allergy and Immunology · doi:10.1111/pai.12563 · Cited by 932
Protein Microarrays for Gene Expression and Antibody Screening
Lueking, A., Horn, M., Eickhoff, H., Büssow, K., Lehrach, H., & Walter, G. (1999) · Analytical Biochemistry · doi:10.1006/abio.1999.4063 · Cited by 433
EAACI Molecular Allergology User's Guide 2.0
Dramburg, S., Hilger, C., Santos, A. F., de las Vecillas, L., Aalberse, R. C., Acevedo, N., Aglas, L., Altmann, F., Arruda, K. L., Asero, R., et al. (2023) · Pediatric Allergy and Immunology · doi:10.1111/pai.13854 · Cited by 298
Richards, K., Rijntjes, E., Rathmann, D., & Köhrle, J. (2017) · Molecular and Cellular Endocrinology · doi:10.1016/j.mce.2017.01.032 · Cited by 23
Metadata
- Authors
- Ekins, R. P.
- Venue
- Clinical Chemistry
- Publisher
- Oxford University Press (OUP)
- Published
- 1998-09-01
- Volume
- 44
- Issue
- 9
- Pages
- 2015-2030
- ISSN
- 0009-9147 (ISSN-L)
- 1530-8561
- OpenAlex
- W2111664616
- Cited by
- 299
- References
- 2
- FWCI
- 3.04
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Ligand assays: from electrophoresis to miniaturized microarrays. https://app.cochat.ai/papers/10.1093/clinchem/44.9.2015
- The paper
- Ekins, R. P. (1998). Ligand assays: from electrophoresis to miniaturized microarrays. Clinical Chemistry. https://doi.org/10.1093/clinchem/44.9.2015
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.