CoChat

Simultaneous Measurement of Allantoin and Urate in Plasma: Analytical Evaluation and Potential Clinical Application in Oxidant:Antioxidant Balance Studies

Benzie, Iris FF, Chung, Wai-yuen, Tomlinson, Brian · 1999 · Clinical Chemistry
Cited by 81

The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.

Abstract

In humans, allantoin is formed by nonenzymatic oxidation of urate; it may, therefore, be useful in assessing oxidative stress(1)(2). Most published methods involve separate analysis of urate and allantoin and require extraction, hydrolysis, and derivatization procedures (1)(2)(3)(4)(5)(6). The primary aim of this study was to evaluate a slightly modified version of an HPLC assay described by Lux et al. (7) for the simultaneous measurement of urate and allantoin. A secondary aim was to explore the clinical utility of allantoin as a biomarker of oxidative stress, the hypothesis being that in disease associated with increased oxidative stress, allantoin increases because of an increased “oxidative turnover” of urate. The final aim of the study was to investigate the effect of age on urate and allantoin concentrations. Allantoin and uric acid were from Sigma; 1-heptanesulfonic acid, sodium salt monohydrate was from Sigma-Aldrich; potassium dihydrogen phosphate was from Merck; sodium hydroxide was from Riedel-de Haen; orthophosphoric acid was from BDH, and Moni-Trol Level 1 Chemistry Control Serum was from Dade International. MilliQ water (Millipore ultra-pure water system; Millipore) was used for preparation of all solutions. Aqueous stock solutions of allantoin (1000 μmol/L) and urate (2000 μmol/L) were prepared and stored at 4 °C. Because uric acid (urate) is more soluble at alkaline pH, sodium hydroxide (1 mol/L) was added dropwise until the pH was ∼9.0; at this pH, all urate was dissolved. Calibrators (10–100 μmol/L for allantoin; 50–1000 μmol/L for urate) were prepared in mobile phase from stock solutions: 25 μL of each calibrator was mixed with 25 μL of Moni-Trol control serum and 75 μL of mobile phase. Ultrafiltrates (see below) of diluted calibrators were used to construct daily calibration curves. For precision studies, we used 1-mL aliquots of pooled heparinized plasma with or without added allantoin (25 μL of stock solution) and urate (250 μL of stock solution) to prepare control samples. For sample preparation, we vortex-mixed 25.0 μL of sample or control with 100 μL of mobile phase, transferred the mixture into a filter unit (Millipore Ultrafree-MC 30 000 NMWL polysulfone-membrane filter unit; Millipore) that had been prewashed twice before use with 300 μL of water to remove the humectant (glycerol), and centrifuged the mixture in a MSE Micro Centaur (MSE Scientific Instruments) at 2500g for 10 min to remove protein and other molecules of Mr >30 000. Ultrafiltrate (20 μL) was injected into the HPLC system, which comprised an isocratic pump (ISCO model 2350 pump with a 20-μL looped Valco manual injector; ISCO), a variable wavelength absorbance detector (ISCO model V4 detector with 5-mm flow cell path), a cartridge guard column (Spherisorb C18, 5 μm, 10 × 4.6 mm i.d. cartridge; ISCO), and a reversed-phase analytical column (ISCO C18, 5 μm, 250 × 4.6 mm i.d.). The mobile phase was aqueous 5 mmol/L potassium dihydrogen phosphate containing 5 mmol/L 1-heptanesulfonic acid (ion-pairing reagent) and adjusted to pH 3.1 using orthophosphoric acid. The flow rate was 1.0 mL/min, and detection was at 210 nm. The peak heights of allantoin and urate were measured manually, using chromatograms recorded by a chart recorder fitted within the detector. By plotting peak height against calibrator concentration, we constructed calibration curves for allantoin and urate. We calculated the concentration (μmol/L) of allantoin or urate in each sample, using peak height over the slope of the calibration curve. The purities of the compounds of interest were not assessed, but were assumed on the basis of previously published data (7). Because urate reportedly is less stable at alkaline pH (2), the stability of the stock urate calibrator (pH 9.4) was assessed. To check whether membrane filtration caused loss of analyte, fresh fasting, heparinized plasma was analyzed with and without filtration. Linearity was assessed by repeated measurements of Moni-Trol control at various concentrations. Recovery was assessed by the addition of allantoin (25 μmol/L) and urate (250 μmol/L) to pooled plasma. A signal-to-noise ratio of 3:1 was used to determine detection limits. This study was approved by the Ethics Subcommittee of the Hong Kong Polytechnic University, and all procedures involving human subjects complied with the Declaration of Helsinki, as revised in 1996. Fasting heparinized plasma samples were obtained from 40 apparently healthy volunteers [23 men, ages 20–55 years; mean (SD), 30.3 (11.9) years; and 17 age-matched women] and 64 subjects with non-insulin-dependent diabetes mellitus [NIDDM; 27 men, ages 32–86 years, mean (SD), 63.4 (14.1) years; and 37 age-matched women]. The NIDDM subjects had been assessed clinically by the treating physician as suffering from early peripheral vascular disease (PVD). Heparin was the preferred anticoagulant because the elution peak of allantoin was completely masked when EDTA-treated or citrat

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1093/clinchem/45.6.901

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 1 references

Cited by

See all 81

Metadata

Authors
Benzie, I. F., Chung, W.-Y., & Tomlinson, B.
Venue
Clinical Chemistry
Published
1999-06-01
Volume
45
Issue
6
Pages
901-904
ISSN
  • 0009-9147 (ISSN-L)
  • 1530-8561
OpenAlex
W2115488145
Cited by
81
References
1
FWCI
1.76
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Simultaneous Measurement of Allantoin and Urate in Plasma: Analytical Evaluation and Potential Clinical Application in Oxidant:Antioxidant Balance Studies. https://app.cochat.ai/papers/10.1093/clinchem/45.6.901
The paper
Benzie, I. F., Chung, W.-Y., & Tomlinson, B. (1999). Simultaneous Measurement of Allantoin and Urate in Plasma: Analytical Evaluation and Potential Clinical Application in Oxidant:Antioxidant Balance Studies. Clinical Chemistry. https://doi.org/10.1093/clinchem/45.6.901

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.