CoChat

Very Small Apolipoprotein A-I-containing Particles from Human Plasma: Isolation and Quantification by High-Performance Size-Exclusion Chromatography

Nanjee, M Nazeem, Brinton, Eliot A · 2000 · Clinical Chemistry
Cited by 54

The DOI matches its Crossref record; 6 of the 6 references it cites were found in a registry or an index.

Abstract

Background: Very small apolipoprotein (apo) A-I-containing lipoprotein (Sm LpA-I) particles with pre-β electrophoretic mobility may play key roles as “nascent” and/or “senescent” HDL; however, methods for their isolation are difficult and often semiquantitative. Methods: We developed a preparative method for separating Sm LpA-I particles from human plasma by high-performance size-exclusion chromatography (HP-SEC), using two gel permeation columns (Superdex 200 and Superdex 75) in series and measuring apo A-I content in column fractions in 30 subjects with HDL-cholesterol (HDL-C) concentrations of 0.4–3.83 mmol/L. Results: Three major sizes of apo A-I-containing particles were detected: an ∼15-nm diameter (∼700 kDa) species; a 7.5–12 nm (100–450 kDa) species; and a 5.8–6.3 nm species (40–60 kDa, Sm LpA-I particles), containing 0.2–3%, 80–96%, and 2–15% of plasma total apo A-I, respectively. Two subjects with severe HDL deficiency had increased relative apo A-I content in Sm LpA-I: 25% and 37%, respectively. The percentage of apo A-I in Sm LpA-I correlated positively with fasting plasma triglyceride concentrations (r = 0.581; P <0.0005) and inversely with total apo A-I (r = −0.551; P <0.0013) and HDL-C concentrations (r = −0.532; P <0.0017), although the latter two relationships were largely attributable to extremely hypoalphalipoproteinemic subjects. The percentage of apo A-I in Sm LpA-I correlated with that in pre-β-migrating species by crossed immunoelectrophoresis (r = 0.98; P <0.0001; n = 24) and with that in the d >1.21 kg/L fraction by ultracentrifugation (r = 0.86; P <0.001; n = 20). Sm LpA-I particles, on average, appear to contain two apo A-I and four phospholipid molecules but little or no apo A-II, triglyceride, or cholesterol. Conclusions: We present a new HP-SEC method for size separation of native HDL particles from plasma, including Sm Lp A-I, which may play important roles in the metabolism of HDL and in its contribution(s) to protection against atherosclerosis. This method provides a basis for further studies of the structure and function of Sm Lp A-I.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1093/clinchem/46.2.207

Cites

6 of 6 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 6 references

Cited by

See all 54

Metadata

Authors
Nanjee, M. N., & Brinton, E. A.
Venue
Clinical Chemistry
Published
2000-02-01
Volume
46
Issue
2
Pages
207-223
ISSN
  • 0009-9147 (ISSN-L)
  • 1530-8561
OpenAlex
W2127055642
Cited by
54
References
6
FWCI
3.07
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Very Small Apolipoprotein A-I-containing Particles from Human Plasma: Isolation and Quantification by High-Performance Size-Exclusion Chromatography. https://app.cochat.ai/papers/10.1093/clinchem/46.2.207
The paper
Nanjee, M. N., & Brinton, E. A. (2000). Very Small Apolipoprotein A-I-containing Particles from Human Plasma: Isolation and Quantification by High-Performance Size-Exclusion Chromatography. Clinical Chemistry. https://doi.org/10.1093/clinchem/46.2.207

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.