CoChat

Vitamin B1 Status Assessed by Direct Measurement of Thiamin Pyrophosphate in Erythrocytes or Whole Blood by HPLC: Comparison with Erythrocyte Transketolase Activation Assay

Talwar, Dinesh, Davidson, Helen, Cooney, Josephine, St. JO’Reilly, Denis · 2000 · Clinical Chemistry
Cited by 204

The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.

Abstract

Background: The concentration of thiamin diphosphate (TDP) in erythrocytes is a useful index of thiamin status. We describe an HPLC method for TDP and its results in patients at risk of thiamin deficiency. Methods: We used reversed-phase HPLC with postcolumn derivatization with alkaline potassium ferricyanide and fluorescence detection. Samples were deproteinized and injected directly onto a C18 column. TDP concentrations in erythrocytes were compared with those in whole blood. Reference intervals for erythrocyte TDP (n = 147; 79 males and 68 females; mean age, 54 years) and whole blood TDP (n = 124; 68 males and 56 females; mean age, 54 years) were determined in an apparently healthy population. We compared erythrocyte TDP with results of the erythrocyte transketolase activation test in 63 patients who were considered at risk of thiamin deficiency. Results: The method was linear to at least 200 μg/L. The between-run CV was <8%. The lower limit of quantification for both whole blood and packed erythrocytes was 300 pg on column with a detection limit of 130 pg on column. Recovery of TDP from blood samples was >90%. TDP in erythrocytes correlated strongly with that in whole blood (r = 0.97). Reference intervals for erythrocyte and whole blood TDP were 280–590 ng/g hemoglobin and 275–675 ng/g hemoglobin, respectively. Of the 63 patients suspected of thiamin deficiency, 46 were normal by both TDP and activation tests, 13 were deficient by both tests, 1 was deficient by the activation test but had normal erythrocyte TDP concentrations, and 4 were normal by the activation test but had low TDP. Conclusions: The HPLC method is precise and yields results similar to the erythrocyte activation assay.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1093/clinchem/46.5.704

Cites

2 of 2 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 204

Metadata

Authors
Talwar, D., Davidson, H., Cooney, J., & St. JO’Reilly, D.
Venue
Clinical Chemistry
Published
2000-05-01
Volume
46
Issue
5
Pages
704-710
ISSN
  • 0009-9147 (ISSN-L)
  • 1530-8561
OpenAlex
W1917350204
Cited by
204
References
2
FWCI
1.28
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.