Cardiac Troponin T and I in End-Stage Renal Failure
Abstract
Background: In patients suffering from end-stage renal failure, cardiac troponin T (cTnT) and I (cTnI) may be increased in serum without other signs of acute myocardial damage. Whether these increases are specific to myocardial injury or nonspecific is not completely clear. Methods: We investigated time courses of cTnT and cTnI over 1 year and the clinical outcome over 2 years in 59 patients with end-stage renal failure undergoing chronic hemodialysis. At the start of the study, we divided the patients into two groups, group 1, without history of cardiac failure, and group 2, with history of cardiac failure, and looked for differences between the groups in later adverse outcome. cTnT was measured using the Enzymun® troponin T assay on an ES 700 analyzer (Roche). cTnI was measured on a Stratus® II analyzer (Dade Behring). Creatinine and blood urea nitrogen were measured on a Vitros® 950 IRC (Ortho). Results: Dialysis acutely increased cTnT (P <0.01) and decreased cTnI (P <0.001) regardless of the dialysis membrane used. Although statistically not significant, cTnT but not cTnI was increased more frequently in group 2 than in group 1, in some cases over the whole study period. Five patients (8.5%) died of cardiac complications within 2 years; all of them had mostly increased cTnT and, in one or more samples, increased cTnI. Conclusions: Dialysis alters measured cTnT and cTnI concentrations in serum. In patients suffering from end-stage renal failure, sporadic or persistently increased cTnT and cTnI appear to predict cardiac complications. Because of the effects of the dialysis procedure on troponin values, we recommend that blood be collected before dialysis.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Antman, E. M., Tanasijevic, M. J., Thompson, B., Schactman, M., McCabe, C. H., Cannon, C. P., Fischer, G. A., Fung, A. Y., Thompson, C., Wybenga, D., et al. (1996) · New England Journal of Medicine · doi:10.1056/nejm199610313351802 · Cited by 1,749
Cited by
Troponin: the biomarker of choice for the detection of cardiac injury
Babuin, L., & Jaffe, A. S. (2005) · Canadian Medical Association Journal · doi:10.1503/cmaj.050141 · Cited by 686
Khan, N. A., Hemmelgarn, B. R., Tonelli, M., Thompson, C. R., & Levin, A. (2005) · Circulation · doi:10.1161/circulationaha.105.560128 · Cited by 351
Preload Induces Troponin I Degradation Independently of Myocardial Ischemia
Feng, J., Schaus, B. J., Fallavollita, J. A., Lee, T.-C., & Canty, J. M. (2001) · Circulation · doi:10.1161/01.cir.103.16.2035 · Cited by 287
Metadata
- Authors
- Wayand, D., Baum, H., Schätzle, G., Schärf, J., & Neumeier, D.
- Venue
- Clinical Chemistry
- Publisher
- Oxford University Press (OUP)
- Published
- 2000-09-01
- Volume
- 46
- Issue
- 9
- Pages
- 1345-1350
- ISSN
- 0009-9147 (ISSN-L)
- 1530-8561
- OpenAlex
- W2172099790
- Cited by
- 178
- References
- 1
- FWCI
- 7.83
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Cardiac Troponin T and I in End-Stage Renal Failure. https://app.cochat.ai/papers/10.1093/clinchem/46.9.1345
- The paper
- Wayand, D., Baum, H., Schätzle, G., Schärf, J., & Neumeier, D. (2000). Cardiac Troponin T and I in End-Stage Renal Failure. Clinical Chemistry. https://doi.org/10.1093/clinchem/46.9.1345
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.