Abstract

Sex hormone-binding globulin (SHBG) is a protein that binds certain androgens and estrogens with high affinity (1)(2) and restricts the access of such steroids to tissues as long as the steroids remain bound to SHBG (3). Measurements of SHBG are often done on a clinical basis and can be used to determine the amounts of free and bioavailable estradiol and testosterone (3)(4)(5). Initially, the measurements were indirect (6)(7)(8)(9), but radioimmunoassays were developed (10)(11). Now several commercial methods are available to measure SHBG directly using the interaction of SHBG with an antibody. We have found marked differences in the values obtained by these methods. Blood samples were obtained from 20 men (ages 21–30 years) and 20 women (ages 21–42 years) between 0800 and 1000. The men and women were healthy by history and a brief physical exam, and were taking no medications. The women all had regular menstrual cycles. The samples were allowed to clot, and the serum was collected, divided into aliquots, and stored at −80 °C until analyzed. Analyses were carried out within 3 months of blood collection. The protocol was approved by the Institutional Review Board of the University of Massachusetts Medical School, and informed consent was obtained from all subjects. Methods A and B were from Diagnostic Systems Laboratories, method C was from Radim (Angleur, Belgium through Wein Laboratories, Succasunna, NJ, and now available through KMI Diagnostics, Minneapolis, MN), and method D was from Diagnostic Products Corporation. Methods A, B, and C were radioimmunoassays using an antibody to SHBG and an antibody to γ-globulin. Method D was an immunometric assay, and method E was an indirect measurement using [3H]dihydrotestosterone and a filter-paper disc to collect the SHBG as described (7)(12). Because the data did not follow a gaussian distribution, the analysis was done using log-transformed data. An analysis of variance indicated a significant difference between the means, and a Bonferroni correction was used to determine the significant differences between the means. A two-tailed t-test was used to analyze the differences between the means for men and women. The characteristics of the methods tested are shown in Table 1 . Methods A–D all used an antibody to SHBG, but the antibodies were raised in different species. The intra- and interassay CVs were in the same range. A major difference was in the expected ranges for men and women, with wide variation for the maximum normal values for both men and women. The results for the men are shown in Fig. 1 . The highest mean value was for assay B, which was approximately fourfold higher than the mean values for assays A and C and twice as high as those of D and E. The mean values for assays A and C were nearly the same (P >0.05), but both means were significantly different (P <0.05) from those for assays D and E. The values for assay B were very different from those of the other assays, whereas D and E, although differing in methodology, were not different in their results (P >0.05). The results for the women are also shown in Fig. 1 . Similar to the results for men, the mean for method B was higher than all the others. Assays A and C were not significantly different, nor were methods D and E (P >0.05), but both assays A and C were significantly different from assays D and E (P <0.05). When the means for men and women were compared within assays, the mean values for women were significantly (P <0.01) higher than the means for the assays in men. The measurement of SHBG often is used clinically in investigations of hyperandrogenicity in women and hypogonadism in men. The SHBG concentration has been used, along with the testosterone concentration, to calculate the percentage and amount of non-protein, or free, testosterone circulating in the blood as well as the amount of albumin-bound testosterone (6)(13)(14). The ratio of the concentrations of testosterone to SHBG has also been used as an index of androgenicity (4)(15). Thus, the measurement of SHBG can be critical to the evaluation of certain patients. It is evident from our data that the result of these calculations can be very different depending on the method used to measure SHBG. The mean percentage of free testosterone calculated by the method of Rosner (14) varied from 1.6% for method B to 3.7% for method C, and the mean indices of androgenicity (testosterone/SHBG) were 0.29 and 0.57, respectively. There are several reasons why the methods might give such disparate results. SHBG exists in several forms in the blood (16)(17)(18), in part because of differences in glycosylation (19)(20). Antibodies raised to SHBG may recognize these forms differently, and thus different antibodies could give disparate results in an immunoassay. Although human SHBG was always the antigen, the antibodies were raised in different species, and this could produce antibodies that recognize SHBG differently. The preparation of the antigens

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1093/clinchem/46.9.1415

Cites

4 of 4 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 4 references

Cited by

See all 30

Metadata

Authors
Bukowski, C., Grigg, M. A., & Longcope, C.
Venue
Clinical Chemistry
Published
2000-09-01
Volume
46
Issue
9
Pages
1415-1416
ISSN
  • 0009-9147 (ISSN-L)
  • 1530-8561
OpenAlex
W1908795463
Cited by
30
References
4
FWCI
0.47
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Sex Hormone-binding Globulin Concentration: Differences Among Commercially Available Methods. https://app.cochat.ai/papers/10.1093/clinchem/46.9.1415
The paper
Bukowski, C., Grigg, M. A., & Longcope, C. (2000). Sex Hormone-binding Globulin Concentration: Differences Among Commercially Available Methods. Clinical Chemistry. https://doi.org/10.1093/clinchem/46.9.1415

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.