Analysis of Dicarboxylic Acids by Tandem Mass Spectrometry. High-Throughput Quantitative Measurement of Methylmalonic Acid in Serum, Plasma, and Urine
The DOI matches its Crossref record.
Abstract
Background: Methylmalonic acid (MMA) is a dicarboxylic acid whose concentration can be increased in blood and urine in patients with an inborn error of metabolism or vitamin B12 deficiency. We developed a method for the selective analysis of dicarboxylic acids that exploits the high specificity of tandem mass spectrometry (MS/MS) and the substantial difference in fragmentation patterns of the isomers methylmalonic (MMA) and succinic acid (SA). Methods: Dicarboxylic acids were extracted from samples with methyl-tert-butyl ether and derivatized with butanolic HCl to form dibutyl esters. The derivative was injected into the liquid chromatography (LC)-MS/MS system using TurboIonSprayTM (nebulizer-assisted electrospray) ionization and quantified by the multiple reaction monitoring mode of MS/MS. Results: The assay for MMA was linear up to 150 μmol/L. The total imprecision was ≤7.5% at both low and high concentrations. The limits of quantification and detection were 0.1 and 0.05 μmol/L, respectively. The degree of interference from SA could be predicted from the branching ratios of the major product ions. Conclusions: The method is specific for dicarboxylic acids. The LC-MS/MS analysis for MMA requires minimal chromatographic separation and takes <60 s per sample. The entire analysis, including sample preparation, for a batch of 100 specimens can be performed in <4 h.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Citric acid cycle intermediates as ligands for orphan G-protein-coupled receptors
He, W., Miao, F. J.-P., Lin, D. C.-H., Schwandner, R. T., Wang, Z., Gao, J., Chen, J.-L., Tian, H., & Ling, L. (2004) · Nature · doi:10.1038/nature02488 · Cited by 909
Anatomical Profiling of G Protein-Coupled Receptor Expression
Regard, J. B., Sato, I. T., & Coughlin, S. R. (2008) · Cell · doi:10.1016/j.cell.2008.08.040 · Cited by 693
Use of Tandem Mass Spectrometry for Multianalyte Screening of Dried Blood Specimens from Newborns
Chace, D. H., Kalas, T. A., & Naylor, E. W. (2003) · Clinical Chemistry · doi:10.1373/clinchem.2003.022178 · Cited by 621
GPCR-Mediated Signaling of Metabolites
Husted, A. S., Trauelsen, M., Rudenko, O., Hjorth, S. A., & Schwartz, T. W. (2017) · Cell Metabolism · doi:10.1016/j.cmet.2017.03.008 · Cited by 590
Succinate, an intermediate in metabolism, signal transduction, ROS, hypoxia, and tumorigenesis
Tretter, L., Patocs, A., & Chinopoulos, C. (2016) · Biochimica et Biophysica Acta (BBA) - Bioenergetics · doi:10.1016/j.bbabio.2016.03.012 · Cited by 539
Triggering the succinate receptor GPR91 on dendritic cells enhances immunity
Rubic, T., Lametschwandtner, G., Jost, S., Hinteregger, S., Kund, J., Carballido-Perrig, N., Schwärzler, C., Junt, T., Voshol, H., Meingassner, J. G., et al. (2008) · Nature Immunology · doi:10.1038/ni.1657 · Cited by 525
“The concentration of succinate detected in the serum of healthy humans is generally around 5 μM (ref”
BackgroundThe succinate receptor GPR91 in neurons has a major role in retinal angiogenesis
Sapieha, P., Sirinyan, M., Hamel, D., Zaniolo, K., Joyal, J.-S., Cho, J.-H., Honoré, J.-C., Kermorvant-Duchemin, E., Varma, D. R., Tremblay, S., et al. (2008) · Nature Medicine · doi:10.1038/nm.1873 · Cited by 359
Toma, I., Kang, J. J., Sipos, A., Vargas, S., Bansal, E., Hanner, F., Meer, E., & Peti-Peterdi, J. (2008) · Journal of Clinical Investigation · doi:10.1172/jci33293 · Cited by 322
The Role of Succinate in the Regulation of Intestinal Inflammation
Connors, J., Dawe, N., & Van Limbergen, J. (2018) · Nutrients · doi:10.3390/nu11010025 · Cited by 316
Compartmentalised acyl-CoA metabolism and roles in chromatin regulation
Trefely, S., Lovell, C. D., Snyder, N. W., & Wellen, K. E. (2020) · Molecular Metabolism · doi:10.1016/j.molmet.2020.01.005 · Cited by 272
Ariza, A. C., Deen, P. M. T., & Robben, J. H. (2012) · Frontiers in Endocrinology · doi:10.3389/fendo.2012.00022 · Cited by 211
“Plasma succinate concentrations measured by liquid chromatography tandem mass spectrometry in rodents vary from 6 to 20 μM, whereas in human succinate levels have been detected from 2 to 3 μM (Sadagopan et al.,2007) and 2 to 20 μM (Kushnir et al., 2001) in serum and plasma, respectively.”
MethodPerformance Characteristics of a Novel Tandem Mass Spectrometry Assay For Serum Testosterone
Kushnir, M. M., Rockwood, A. L., Roberts, W. L., Pattison, E. G., Bunker, A. M., Fitzgerald, R. L., & Meikle, A. W. (2006) · Clinical Chemistry · doi:10.1373/clinchem.2005.052167 · Cited by 170
Self-citationSodium-coupled dicarboxylate and citrate transporters from the SLC13 family
Pajor, A. M. (2014) · Pflügers Archiv - European Journal of Physiology · doi:10.1007/s00424-013-1369-y · Cited by 163
“Plasma concentrations of these metabolic intermediates in humans are: citrate ~120 μM [27, 67], succinate ~5 μM [52], α-ketoglutarate ~25 μM [52], and glutarate 0.”
BackgroundDevelopment and Performance Evaluation of a Tandem Mass Spectrometry Assay for 4 Adrenal Steroids
Kushnir, M. M., Rockwood, A. L., Roberts, W. L., Pattison, E. G., Owen, W. E., Bunker, A. M., & Meikle, A. W. (2006) · Clinical Chemistry · doi:10.1373/clinchem.2006.068445 · Cited by 125
Self-citationMu, X., Zhao, T., Xu, C., Shi, W., Geng, B., Shen, J., Zhang, C., Pan, J., Yang, J., Hu, S., et al. (2017) · Oncotarget · doi:10.18632/oncotarget.14485 · Cited by 124
“It is normally present in the circulation of blood at about 5μM concentration [7, 8], while under pathological conditions it is accumulated in extra-cellular spaces.”
BackgroundExpression and localization of GPR91 and GPR99 in murine organs
Diehl, J., Gries, B., Pfeil, U., Goldenberg, A., Mermer, P., Kummer, W., & Paddenberg, R. (2016) · Cell and Tissue Research · doi:10.1007/s00441-015-2318-1 · Cited by 50
“Blood concentrations of succinate have been reported to be in the range of 6–20 μM for rodents and 2–20 μM for humans (Sadagopan et al. 2007; Kushnir et al. 2001), and 20–30 μM succinate has been measured in urine of mice (Toma et al. 2008).”
Donti, T. R., Stromberger, C., Ge, M., Eldin, K. W., Craigen, W. J., & Graham, B. H. (2013) · Disease Models & Mechanisms · doi:10.1242/dmm.013466 · Cited by 25
“Tissue content of MMA was determined by liquid chromatography combined with tandem mass spectrometry (HPLC-MS/MS) using a method modified from previous publications (Kushnir et al., 2001; Schmedes and Brandslund, 2006).”
Method
Metadata
- Authors
- Kushnir, M. M., Komaromy-Hiller, G., Shushan, B., Urry, F. M., & Roberts, W. L.
- Venue
- Clinical Chemistry
- Publisher
- Oxford University Press (OUP)
- Published
- 2001-11-01
- Volume
- 47
- Issue
- 11
- Pages
- 1993-2002
- ISSN
- 0009-9147 (ISSN-L)
- 1530-8561
- OpenAlex
- W1824800962
- Cited by
- 169
- References
- 0
- FWCI
- 3.20
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.