Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 252

The DOI matches its Crossref record; 18 of the 18 references it cites were found in a registry or an index.

Characteristics of an Albumin Cobalt Binding Test for Assessment of Acute Coronary Syndrome Patients: A Multicenter Study

Open access
Christenson, Robert H, Duh, Show Hong, Sanhai, Wendy R, Wu, Alan H B, Holtman, Verena, Painter, Pennell, Branham, Elizabeth, Apple, Fred S, Murakami, MaryAnn, Morris, Deborah L · 2001 · Clinical Chemistry

Abstract

Background: The ability of the N-terminal region of human albumin to bind cobalt is diminished by myocardial ischemia. The characteristics of an assay based on albumin cobalt binding were assessed in suspected acute coronary syndrome patients and in a control reference population. The ability of the Albumin Cobalt Binding (ACBTM) Test measurement at presentation to predict troponin-positive or -negative results 6–24 h later was also examined. Methods: We enrolled 256 acute coronary syndrome patients at four medical centers. Blood specimens were collected at presentation and then 6–24 h later. The dichotomous decision limit and performance characteristics of the ACB Test for predicting troponin-positive or -negative status 6 h-24 h later were determined using ROC curve analysis. Results for 32 patients could not be used because the time of onset of ischemia appeared to have been >3 h before presentation or was uncertain. The reference interval was determined by parametric analysis to estimate the upper 95th percentile of a reference population (n = 109) of ostensibly healthy individuals. Results: Increased cTnI was found in 35 of 224 patients. The ROC curve area for the ACB Test was 0.78 [95% confidence interval (CI), 0.70–0.86]. At the optimum decision point of 75 units/mL, the sensitivity and specificity of the ACB Test were 83% (95% CI, 66–93%) and 69% (95% CI, 62–76%). The negative predictive value was 96% (95% CI, 91–98%), and the positive predictive value was 33% (95% CI, 24–44%). The within-run CV of the ACB Test was 7.3%. Results for the reference population were normally distributed; the one-sided parametric 95th percentile was 80.2 units/mL. Conclusions: This exploratory study suggests that the ACB Test has high negative predictive value and sensitivity in the presentation sample for predicting troponin-negative or -positive results 6–24 h later.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1093/clinchem/47.3.464

Cites

18 of 18 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 18 references

Cited by

See all 252

Metadata

Authors
Christenson, R. H., Duh, S. H., Sanhai, W. R., Wu, A. H. B., Holtman, V., Painter, P., Branham, E., Apple, F. S., Murakami, M., & Morris, D. L.
Venue
Clinical Chemistry
Published
2001-03-01
Volume
47
Issue
3
Pages
464-470
ISSN
  • 0009-9147 (ISSN-L)
  • 1530-8561
OpenAlex
W1957364659
Cited by
252
References
18
FWCI
7.71
Type
journal article
Language
en
Open access
green

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Characteristics of an Albumin Cobalt Binding Test for Assessment of Acute Coronary Syndrome Patients: A Multicenter Study. https://app.cochat.ai/papers/10.1093/clinchem/47.3.464
The paper
Christenson, R. H., Duh, S. H., Sanhai, W. R., Wu, A. H. B., Holtman, V., Painter, P., Branham, E., Apple, F. S., Murakami, M., & Morris, D. L. (2001). Characteristics of an Albumin Cobalt Binding Test for Assessment of Acute Coronary Syndrome Patients: A Multicenter Study. Clinical Chemistry. https://doi.org/10.1093/clinchem/47.3.464

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.