Comprehensive Screening of Urine Samples for Inborn Errors of Metabolism by Electrospray Tandem Mass Spectrometry
The DOI matches its Crossref record.
Abstract
Background: Detection of abnormal metabolites in urine is important for the diagnosis of many inborn errors of metabolism (IEM). Rapid, comprehensive screening methods are needed. Methods: We used electrospray ionization tandem mass spectrometry in positive- and negative-ion modes to detect selected metabolites in urine. For positive-ion analysis, samples were dried and butylated, whereas for negative-ion analysis, samples were merely diluted with the mobile phase. Analysis was by direct injection with multiple reaction monitoring for 32 metabolites in positive mode (amino acids and acylcarnitines) and 30 metabolites in negative mode (organic acids). Run time was 2.1 min in each mode. Results: Interbatch CVs ranged from 4.8% to 32%, enabling quantification of many metabolites. The procedure was applied to controls (278 and 120 in positive- and negative-ion mode, respectively) and 108 IEM individuals representing 37 different IEM. In 105 IEM individuals, representing 36 different IEM, concentrations of one or more diagnostic metabolites were above the 99th percentiles of the control values. Conclusions: The procedure is faster and less labor-intensive than conventional methods of testing for IEM by amino and organic acid profiling and has similar diagnostic sensitivity. The ability to include a greater range of metabolites offers the potential of a more comprehensive screening procedure.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Measuring the metabolome: current analytical technologies
Dunn, W. B., Bailey, N. J. C., & Johnson, H. E. (2005) · The Analyst · doi:10.1039/b418288j · Cited by 924
Mitochondrial dysfunction and molecular pathways of disease
Pieczenik, S. R., & Neustadt, J. (2007) · Experimental and Molecular Pathology · doi:10.1016/j.yexmp.2006.09.008 · Cited by 637
Carr, S. A., Abbatiello, S. E., Ackermann, B. L., Borchers, C., Domon, B., Deutsch, E. W., Grant, R. P., Hoofnagle, A. N., Hüttenhain, R., Koomen, J. M., et al. (2014) · Molecular & Cellular Proteomics · doi:10.1074/mcp.m113.036095 · Cited by 561
Metabolic Fingerprinting As A Diagnostic Tool
Ellis, D. I., Dunn, W. B., Griffin, J. L., Allwood, J. W., & Goodacre, R. (2007) · Pharmacogenomics · doi:10.2217/14622416.8.9.1243 · Cited by 396
Systems biology, metabolic modelling and metabolomics in drug discovery and development
Kell, D. B. (2006) · Drug Discovery Today · doi:10.1016/j.drudis.2006.10.004 · Cited by 297
Piraud, M., Vianey‐Saban, C., Petritis, K., Elfakir, C., Steghens, J., Morla, A., & Bouchu, D. (2003) · Rapid Communications in Mass Spectrometry · doi:10.1002/rcm.1054 · Cited by 266
Untargeted metabolomic analysis for the clinical screening of inborn errors of metabolism
Miller, M. J., Kennedy, A. D., Eckhart, A. D., Burrage, L. C., Wulff, J. E., Miller, L. A. D., Milburn, M. V., Ryals, J. A., Beaudet, A. L., Sun, Q., et al. (2015) · Journal of Inherited Metabolic Disease · doi:10.1007/s10545-015-9843-7 · Cited by 212
“Many prior metabolomic analyses of IEM patient specimens have focused on targeted mass spectrometry (MS) based approaches capable of providing absolute quantitation for a subset of predetermined analytes (Pitt et al 2002; Kuhara 2005; Janeckova et al 2012).”
BackgroundSuccessful Treatment of Molybdenum Cofactor Deficiency Type A With cPMP
Veldman, A., Santamaria-Araujo, J. A., Sollazzo, S., Pitt, J., Gianello, R., Yaplito-Lee, J., Wong, F., Ramsden, C. A., Reiss, J., Cook, I., et al. (2010) · Pediatrics · doi:10.1542/peds.2009-2192 · Cited by 197
Self-citationGao, A. W., Chatzispyrou, I. A., Kamble, R., Liu, Y. J., Herzog, K., Smith, R. L., van Lenthe, H., Vervaart, M. A. T., van Cruchten, A., Luyf, A. C., et al. (2017) · Scientific Reports · doi:10.1038/s41598-017-02539-w · Cited by 77
“For the measurement of FAs we applied MS, and for AAs we used UPLC-MS/MS (Nagy et al., 2003; Pitt et al., 2002; Valianpour et al., 2003).”
Pereira-Fantini, P. M., Byars, S. G., Pitt, J., Lapthorne, S., Fouhy, F., Cotter, P. D., & Bines, J. E. (2017) · Scientific Reports · doi:10.1038/srep43326 · Cited by 22
Self-citationHeath, O., Pandithan, D., Pitt, J., Savva, E., Raiti, L., Bracken, J., Vandeleur, M., Delatycki, M. B., Yaplito‐Lee, J., Hardikar, W., et al. (2023) · JIMD Reports · doi:10.1002/jmd2.12390 · Cited by 2
“Other urine metabolites were measured by flow-injection tandem mass spectrometry using targeted multiple reaction monitoring as previously described.(10) FibroScanTM was undertaken with the Echosens machine, S1 probe and 10 successful measurements.”
MethodSelf-citation
Metadata
- Authors
- Pitt, J. J., Eggington, M., & Kahler, S. G.
- Venue
- Clinical Chemistry
- Publisher
- Oxford University Press (OUP)
- Published
- 2002-11-01
- Volume
- 48
- Issue
- 11
- Pages
- 1970-1980
- ISSN
- 0009-9147 (ISSN-L)
- 1530-8561
- OpenAlex
- W2103860618
- Cited by
- 123
- References
- 0
- FWCI
- 3.06
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.