The DOI matches its Crossref record.
Steady and Pulsatile Energy Losses in the Systemic Circulation under Normal Conditions and in Simulated Arterial Disease
Abstract
External left ventricular work was calculated from records of pressure and flow in the ascending aorta of 1 unanaesthetized and 21 anaesthetized dogs. Work was divided into pulsatile and steady components, the former representing energy lost in vascular pulsations and the latter, energy lost in maintaining steady flow. The ratio of pulsatile to total (steady + pulsatile) external work averaged 10% under control conditions but increased markedly when heart rate slowed, when cardiac output rose, or when arterial distensibility was impaired.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
O’Rourke, M. F., & Safar, M. E. (2005) · Hypertension · doi:10.1161/01.hyp.0000168052.00426.65 · Cited by 1,279
Self-citationMechanical Factors in Arterial Aging
O’Rourke, M. F., & Hashimoto, J. (2007) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2006.12.050 · Cited by 1,250
Self-citationO’Rourke, M. F., & Nichols, W. W. (2005) · Hypertension · doi:10.1161/01.hyp.0000153793.84859.b8 · Cited by 543
Self-citationKelly, R., & Fitchett, D. (1992) · Journal of the American College of Cardiology · doi:10.1016/0735-1097(92)90198-v · Cited by 361
Poppas, A., Shroff, S. G., Korcarz, C. E., Hibbard, J. U., Berger, D. S., Lindheimer, M. D., & Lang, R. M. (1997) · Circulation · doi:10.1161/01.cir.95.10.2407 · Cited by 360
Metadata
- Authors
- O'Rourke, M. F.
- Venue
- Cardiovascular Research
- Publisher
- Oxford University Press (OUP)
- Published
- 1967-10-01
- Volume
- 1
- Issue
- 4
- Pages
- 313-326
- ISSN
- 0008-6363 (ISSN-L)
- OpenAlex
- W2116798960
- Cited by
- 215
- References
- 0
- FWCI
- 0.54
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Steady and Pulsatile Energy Losses in the Systemic Circulation under Normal Conditions and in Simulated Arterial Disease. https://app.cochat.ai/papers/10.1093/cvr/1.4.313
- The paper
- O'Rourke, M. F. (1967). Steady and Pulsatile Energy Losses in the Systemic Circulation under Normal Conditions and in Simulated Arterial Disease. Cardiovascular Research. https://doi.org/10.1093/cvr/1.4.313
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.