CoChat

Species variation in the coronary collateral circulation during regional myocardial ischaemia: a critical determinant of the rate of evolution and extent of myocardial infarction

Open access
MAXWELL, M. P, HEARSE, D. J, YELLON, D. M · 1987 · Cardiovascular Research
Cited by 515

The DOI matches its Crossref record; 17 of the 17 references it cites were found in a registry or an index.

Abstract

To determine residual flow to ischaemic tissue, which is the primary determinant of the rate of development and ultimate size of the myocardial infarct resulting from coronary artery occlusion, the coronary collateral circulation was quantified during acute myocardial ischaemia in eight species in vivo using the radiolabelled microsphere technique. In each case, a prominent branch of the left coronary artery was ligated, and within 5 min microspheres (141Ce labelled, 15 micron diameter) were injected intra-atrially. Hearts were then excised, frozen, and sliced perpendicular to the septum. Using autoradiograms as a guide, tissue samples were obtained from non-ischaemic and ischaemic tissue and the radioactivity of the ischaemic samples measured and expressed as a percentage of the activity in the non-ischaemic myocardium. In the guinea pig heart, despite ligation of a major artery, no zone of significant underperfusion was detected. In the hearts from other species, coronary collateral flow (as a percentage (mean(SEM)) of non-ischaemic flow) was: dog 15.9(1.8) (n = 6); cat 11.8(1.1) (n = 16); rat 6.1(0.7) (n = 6); ferret 2.4(0.6) (n = 6); baboon 2.1(0.3) (n = 6); rabbit 2.0(0.5) (n = 9); pig 0.6(0.2) (n = 6). The dog and cat hearts both possessed transmural gradients of collateral flow with greatest delivery in the epicardium. The patterns of flow distribution in the guinea pig heart were further examined in a Langendorff perfused preparation. Blue dye was injected into the coronary circulation and its distribution over 5 s recorded on cine film. After ligation of the left anterior descending or circumflex arteries, or both, the perfusion field of these arteries was seen to fill retrogradely within seconds. It is concluded that a wide spectrum of collateral flow exists between various mammalian species, a fact that should be taken into account in the study of the pathophysiology and control of regional ischaemia and myocardial infarction.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1093/cvr/21.10.737

Cites

17 of 17 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Cited by

See all 515

Metadata

Authors
MAXWELL, M. P., HEARSE, D. J., & YELLON, D. M.
Venue
Cardiovascular Research
Published
1987-10-01
Volume
21
Issue
10
Pages
737-746
ISSN
0008-6363 (ISSN-L)
OpenAlex
W2070364693
Cited by
515
References
17
FWCI
5.56
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.