CoChat

The magnetocardiogram in cardiac disorders

SAARINEN, M., KARP, P. J., KATILA, T. E., SILTANEN, P. · 1974 · Cardiovascular Research
Cited by 61

The DOI matches its Crossref record.

Abstract

Magnetocardiograms of 24 normal subjects and of 31 patients with cardiac disorders have been studied with the aid of a magnetometer of the gradiometer principle which utilizes a superconducting quantum interference device (SQUID). The precordial magnetocardiograms observed are closely related to the conventional 12-lead electrocardiogram, but also reveal new information as compared with the standard ECG. There are differences between MCGs in different cardiac disorders, but the small number of cases and recording positions applied do not permit analysis of the specifity of the MCG patterns. There are certain differences between 12-lead ECG and precordial MCG in the relative sensitivity to different phases of the cardiac electromotive events. For instance, the magnitude of an S-T segment shift, as measured relative to QRS amplitude, was greater in the MCG. A part of these differences may be explained by a greater proximity effect in magnetocardiography. Magnetocardiography may prove to be of clinical value in cardiac disorders, especially in those producing primary abnormalities in the repolarization process.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1093/cvr/8.6.820

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 61

Metadata

Authors
SAARINEN, M., KARP, P. J., KATILA, T. E., & SILTANEN, P.
Venue
Cardiovascular Research
Published
1974-11-01
Volume
8
Issue
6
Pages
820-834
ISSN
0008-6363 (ISSN-L)
OpenAlex
W2025015841
Cited by
61
References
0
FWCI
2.91
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: The magnetocardiogram in cardiac disorders. https://app.cochat.ai/papers/10.1093/cvr/8.6.820
The paper
SAARINEN, M., KARP, P. J., KATILA, T. E., & SILTANEN, P. (1974). The magnetocardiogram in cardiac disorders. Cardiovascular Research. https://doi.org/10.1093/cvr/8.6.820

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.