Deep learning for vessel-specific coronary artery calcium scoring: validation on a multi-centre dataset
The DOI matches its Crossref record; 6 of the 6 references it cites were found in a registry or an index.
Abstract
Aims: To present and validate a fully automated, deep learning (DL)-based branch-wise coronary artery calcium (CAC) scoring algorithm on a multi-centre dataset. Methods and results: We retrospectively included 1171 patients referred for a CAC computed tomography examination. Total CAC scores for each case were manually evaluated by a human reader. Next, each dataset was fully automatically evaluated by the DL-based software solution with output of the total CAC score and sub-scores per coronary artery (CA) branch [right coronary artery (RCA), left main (LM), left anterior descending (LAD), and circumflex (CX)]. Three readers independently manually scored the CAC for all CA branches for 300 cases from a single centre and formed the consensus using a majority vote rule, serving as the reference standard. Established CAC cut-offs for the total Agatston score were used for risk group assignments. The performance of the algorithm was evaluated using metrics for risk class assignment based on total Agatston score, and unweighted Cohen’s Kappa for branch label assignment. The DL-based software solution yielded a class accuracy of 93% (1085/1171) with a sensitivity, specificity, and accuracy of detecting non-zero coronary calcium being 97%, 93%, and 95%. The overall accuracy of the algorithm for branch label classification was 94% (LM: 89%, LAD: 91%, CX: 93%, RCA: 100%) with a Cohen's kappa of k = 0.91. Conclusion: Our results demonstrate that fully automated total and vessel-specific CAC scoring is feasible using a DL-based algorithm. There was a high agreement with the manually assessed total CAC from a multi-centre dataset and the vessel-specific scoring demonstrated consistent and reproducible results.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT
Martin Bland, J., & Altman, D. (1986) · The Lancet · doi:10.1016/s0140-6736(86)90837-8 · Cited by 47,965
2016 European Guidelines on cardiovascular disease prevention in clinical practice
Piepoli, M. F., Hoes, A. W., Agewall, S., Albus, C., Brotons, C., Catapano, A. L., Cooney, M.-T., Corrà, U., Cosyns, B., Deaton, C., et al. (2016) · European Heart Journal · doi:10.1093/eurheartj/ehw106 · Cited by 6,457
van Velzen, S. G. M., Lessmann, N., Velthuis, B. K., Bank, I. E. M., van den Bongard, D. H. J. G., Leiner, T., de Jong, P. A., Veldhuis, W. B., Correa, A., Terry, J. G., et al. (2020) · Radiology · doi:10.1148/radiol.2020191621 · Cited by 244
Deep convolutional neural networks to predict cardiovascular risk from computed tomography
Zeleznik, R., Foldyna, B., Eslami, P., Weiss, J., Alexander, I., Taron, J., Parmar, C., Alvi, R. M., Banerji, D., Uno, M., et al. (2021) · Nature Communications · doi:10.1038/s41467-021-20966-2 · Cited by 240
Direct Automatic Coronary Calcium Scoring in Cardiac and Chest CT
de Vos, B. D., Wolterink, J. M., Leiner, T., de Jong, P. A., Lessmann, N., & Isgum, I. (2019) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2019.2899534 · Cited by 134
Evaluation of a Deep Learning–Based Automated CT Coronary Artery Calcium Scoring Algorithm
Martin, S. S., van Assen, M., Rapaka, S., Hudson, H. T., Fischer, A. M., Varga-Szemes, A., Sahbaee, P., Schwemmer, C., Gulsun, M. A., Cimen, S., et al. (2020) · JACC: Cardiovascular Imaging · doi:10.1016/j.jcmg.2019.09.015 · Cited by 75
Self-citation
Cited by
Gennari, A. G., Rossi, A., De Cecco, C. N., van Assen, M., Sartoretti, T., Giannopoulos, A. A., Schwyzer, M., Huellner, M. W., & Messerli, M. (2024) · The International Journal of Cardiovascular Imaging · doi:10.1007/s10554-024-03080-4 · Cited by 16
“Additionally, experts-to-AI intraclass correlation coefficient (ICC) values ranging from 0.84 to 0.99 were reported by several authors [84–88], while the expert-to-expert ones were 0.84, 0.85, and 0.77 [84].”
BackgroundResultInfluentialWang, T.-W., Tzeng, Y.-H., Wu, K.-T., Liu, H.-R., Hong, J.-S., Hsu, H.-Y., Fu, H.-N., Lee, Y.-T., Yin, W.-H., & Wu, Y.-T. (2024) · Computers in Biology and Medicine · doi:10.1016/j.compbiomed.2024.109295 · Cited by 14
Zhou, J., Shanbhag, A. D., Han, D., Marcinkiewicz, A. M., Buchwald, M., Miller, R. J. H., Killekar, A., Manral, N., Grodecki, K., Geers, J., et al. (2025) · European Heart Journal - Cardiovascular Imaging · doi:10.1093/ehjci/jeaf007 · Cited by 6
Metadata
- Authors
- Winkel, D. J., Suryanarayana, V. R., Ali, A. M., Görich, J., Buß, S. J., Mendoza, A., Schwemmer, C., Sharma, P., Schoepf, U. J., & Rapaka, S.
- Venue
- European Heart Journal - Cardiovascular Imaging
- Publisher
- Oxford University Press (OUP)
- Published
- 2021-07-29
- Volume
- 23
- Issue
- 6
- Pages
- 846-854
- ISSN
- 2047-2404 (ISSN-L)
- 2047-2412
- OpenAlex
- W3183856851
- Cited by
- 51
- References
- 6
- FWCI
- 3.89
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Deep learning for vessel-specific coronary artery calcium scoring: validation on a multi-centre dataset. https://app.cochat.ai/papers/10.1093/ehjci/jeab119
- The paper
- Winkel, D. J., Suryanarayana, V. R., Ali, A. M., Görich, J., Buß, S. J., Mendoza, A., Schwemmer, C., Sharma, P., Schoepf, U. J., & Rapaka, S. (2022). Deep learning for vessel-specific coronary artery calcium scoring: validation on a multi-centre dataset. European Heart Journal - Cardiovascular Imaging. https://doi.org/10.1093/ehjci/jeab119
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.