Normal values and clinical relevance of left atrial myocardial function analysed by speckle-tracking echocardiography: multicentre study
The DOI matches its Crossref record; 39 of the 39 references it cites were found in a registry or an index.
Abstract
AIMS: The aim of this multicentre study was to determine the normal range and the clinical relevance of the myocardial function of the left atrium (LA) analysed by 2D speckle-tracking echocardiography (2DSTE). METHODS AND RESULTS: We analysed 329 healthy adult subjects prospectively included in 10 centres and a validation group of 377 patients with left ventricular diastolic dysfunction (LVDD). LA myocardial function was analysed by LA strain rate peak during LA contraction (LA-SRa) and LA strain peak during LA relaxation (LA-Strain). The range of values of LA myocardial function in healthy subjects was LA-SRa -2.11 ± 0.61 s(-1) and LA-Strain 45.5 ± 11.4%, and the lowest expected values of these LA analyses (calculated as -1.96 SD from the mean of healthy subjects) were LA-SRa -0.91 s(-1) and LA-Strain 23.1%. Concerning the clinical relevance of these LA myocardial analyses, LA-SRa and LA-Strain detected subtle LA dysfunction in patients with LVDD, even though LA volumetric measurements were normal. In addition, in these patients we found that the functional class (dyspnoea-NYHA classification) was inversely related to both LA-Strain and LA-SRa. CONCLUSION: In the present multicentre study analysing a large cohort of healthy subjects and patients with LVDD, the normal range and the clinical relevance of the myocardial function of the LA using 2DSTE have been determined.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Recommendations for the Evaluation of Left Ventricular Diastolic Function by Echocardiography
Nagueh, S. F., Appleton, C. P., Gillebert, T. C., Marino, P. N., Oh, J. K., Smiseth, O. A., Waggoner, A. D., Flachskampf, F. A., Pellikka, P. A., & Evangelista, A. (2009) · Journal of the American Society of Echocardiography · doi:10.1016/j.echo.2008.11.023 · Cited by 4,367
Authors/Task Force Members, Vahanian, A., Baumgartner, H., Bax, J., Butchart, E., Dion, R., Filippatos, G., Flachskampf, F., Hall, R., Iung, B., et al. (2006) · European Heart Journal · doi:10.1093/eurheartj/ehl428 · Cited by 3,593
Recommendations for chamber quantification☆
LANG, R., BIERIG, M., DEVEREUX, R., FLACHSKAMPF, F., FOSTER, E., PELLIKKA, P., PICARD, M., ROMAN, M., SEWARD, J., & SHANEWISE, J. (2006) · European Journal of Echocardiography · doi:10.1016/j.euje.2005.12.014 · Cited by 3,571
Guidelines on the management of valvular heart disease (version 2012)
Authors/Task Force Members, Vahanian, A., Alfieri, O., Andreotti, F., Antunes, M. J., Barón-Esquivias, G., Baumgartner, H., Borger, M. A., Carrel, T. P., De Bonis, M., et al. (2012) · European Heart Journal · doi:10.1093/eurheartj/ehs109 · Cited by 3,559
Recommendations for the evaluation of left ventricular diastolic function by echocardiography
Nagueh, S. F., Appleton, C. P., Gillebert, T. C., Marino, P. N., Oh, J. K., Smiseth, O. A., Waggoner, A. D., Flachskampf, F. A., Pellikka, P. A., & Evangelisa, A. (2008) · European Journal of Echocardiography · doi:10.1093/ejechocard/jep007 · Cited by 3,351 · cited 4×
“LV diameters, LV volumes, LV mass, LVEF (Simpson’s method), LV diastolic function, grade of LVDD, and LA volumetric measurements were assessed as recommended by the EACI.29,30 LAvolumetric analyses were performed using the Simpson’s method.1,2,11,20,29,34 LA Downloaded from https://academic.oup.com/ehjcimaging/article…”
MethodInfluentialMor-Avi, V., Lang, R. M., Badano, L. P., Belohlavek, M., Cardim, N. M., Derumeaux, G., Galderisi, M., Marwick, T., Nagueh, S. F., Sengupta, P. P., et al. (2011) · European Journal of Echocardiography · doi:10.1093/ejechocard/jer021 · Cited by 1,080
Self-citationMondillo, S., Cameli, M., Caputo, M. L., Lisi, M., Palmerini, E., Padeletti, M., & Ballo, P. (2011) · Journal of the American Society of Echocardiography · doi:10.1016/j.echo.2011.04.014 · Cited by 426
Cameli, M., Caputo, M., Mondillo, S., Ballo, P., Palmerini, E., Lisi, M., Marino, E., & Galderisi, M. (2009) · Cardiovascular Ultrasound · doi:10.1186/1476-7120-7-6 · Cited by 389
Saraiva, R. M., Demirkol, S., Buakhamsri, A., Greenberg, N., Popović, Z. B., Thomas, J. D., & Klein, A. L. (2010) · Journal of the American Society of Echocardiography · doi:10.1016/j.echo.2009.11.003 · Cited by 358
Vianna-Pinton, R., Moreno, C. A., Baxter, C. M., Lee, K. S., Tsang, T. S. M., & Appleton, C. P. (2009) · Journal of the American Society of Echocardiography · doi:10.1016/j.echo.2008.12.017 · Cited by 338
Cited by
Left Atrial Structure and Function, and Left Ventricular Diastolic Dysfunction
Thomas, L., Marwick, T. H., Popescu, B. A., Donal, E., & Badano, L. P. (2019) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2019.01.059 · Cited by 653
Pathan, F., D'Elia, N., Nolan, M. T., Marwick, T. H., & Negishi, K. (2017) · Journal of the American Society of Echocardiography · doi:10.1016/j.echo.2016.09.007 · Cited by 581
LA Strain for Categorization of LV Diastolic Dysfunction
Singh, A., Addetia, K., Maffessanti, F., Mor-Avi, V., & Lang, R. M. (2017) · JACC: Cardiovascular Imaging · doi:10.1016/j.jcmg.2016.08.014 · Cited by 458
Freed, B. H., Daruwalla, V., Cheng, J. Y., Aguilar, F. G., Beussink, L., Choi, A., Klein, D. A., Dixon, D., Baldridge, A., Rasmussen-Torvik, L. J., et al. (2016) · Circulation: Cardiovascular Imaging · doi:10.1161/circimaging.115.003754 · Cited by 395
Morris, D. A., Belyavskiy, E., Aravind-Kumar, R., Kropf, M., Frydas, A., Braunauer, K., Marquez, E., Krisper, M., Lindhorst, R., Osmanoglou, E., et al. (2018) · JACC: Cardiovascular Imaging · doi:10.1016/j.jcmg.2017.07.029 · Cited by 388
Self-citationLeft Atrial Reverse Remodeling
Thomas, L., & Abhayaratna, W. P. (2017) · JACC: Cardiovascular Imaging · doi:10.1016/j.jcmg.2016.11.003 · Cited by 385
Smiseth, O. A., Morris, D. A., Cardim, N., Cikes, M., Delgado, V., Donal, E., Flachskampf, F. A., Galderisi, M., Gerber, B. L., Gimelli, A., et al. (2022) · European Heart Journal - Cardiovascular Imaging · doi:10.1093/ehjci/jeab154 · Cited by 347
Self-citationReddy, Y. N. V., Obokata, M., Egbe, A., Yang, J. H., Pislaru, S., Lin, G., Carter, R., & Borlaug, B. A. (2019) · European Journal of Heart Failure · doi:10.1002/ejhf.1464 · Cited by 316
Left atrial function: evaluation by strain analysis
Gan, G. C. H., Ferkh, A., Boyd, A., & Thomas, L. (2018) · Cardiovascular Diagnosis and Therapy · doi:10.21037/cdt.2017.06.08 · Cited by 206
Metadata
- Authors
- Morris, D. A., Takeuchi, M., Krisper, M., Kohncke, C., Bekfani, T., Carstensen, T., Hassfeld, S., Dorenkamp, M., Otani, K., Takigiku, K., Izumi, C., Yuda, S., Sakata, K., Ohte, N., Tanabe, K., Osmanoglou, E., Kuhnle, Y., Dungen, H.-D., Nakatani, S., Otsuji, Y., Haverkamp, W., & Boldt, L.-H.
- Venue
- European Heart Journal - Cardiovascular Imaging
- Publisher
- Oxford University Press (OUP)
- Published
- 2014-11-03
- Volume
- 16
- Issue
- 4
- Pages
- 364-372
- ISSN
- 2047-2404 (ISSN-L)
- 2047-2412
- OpenAlex
- W2126886827
- Cited by
- 276
- References
- 39
- FWCI
- 6.32
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.