The utility of handheld echocardiography for early rheumatic heart disease diagnosis: a field study
Open accessThe DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
AIMS: The World Heart Federation (WHF) guidelines for rheumatic heart disease (RHD) are designed for a standard portable echocardiography (STAND) machine. A recent study in a tertiary care centre demonstrated that they also had good sensitivity and specificity when modified for use with handheld echocardiography (HAND). Our study aimed to evaluate the performance of HAND for early RHD diagnosis in the setting of a large-scale field screening. METHODS AND RESULTS: STAND was performed in 4773 children in Gulu, Uganda, with 10% randomly assigned to also undergo HAND. Additionally, any child with mitral or aortic regurgitation also underwent HAND. Studies were performed by experienced echocardiographers and blindly reviewed by cardiologists using 2012 WHF criteria, which were modified slightly for HAND--due to the lack of spectral Doppler capability. Paired echocardiograms were performed in 1420 children (mean age 10.8 and 53% female), resulting in 1234 children who were normal, 133 who met criteria for borderline RHD, 47 who met criteria for definite RHD, and 6 who had other diagnoses. HAND had good sensitivity and specificity for RHD detection (78.9 and 87.2%, respectively), but was most sensitive for definite RHD (97.9%). Inter- and intra-reviewer agreement ranged between 66-83 and 71.4-94.1%, respectively. CONCLUSIONS: HAND has good sensitivity and specificity for diagnosis of early RHD, performing best for definite RHD. Protocols for RHD detection utilizing HAND will need to include confirmation by STAND to avoid over-diagnosis. Strategies that evaluate simplified screening protocols and training of non-physicians hold promise for more wide spread deployment of HAND-based protocols.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Harris, P. A., Taylor, R., Thielke, R., Payne, J., Gonzalez, N., & Conde, J. G. (2009) · Journal of Biomedical Informatics · doi:10.1016/j.jbi.2008.08.010 · Cited by 51,384
Cited by
Acute rheumatic fever and rheumatic heart disease
Carapetis, J. R., Beaton, A., Cunningham, M. W., Guilherme, L., Karthikeyan, G., Mayosi, B. M., Sable, C., Steer, A., Wilson, N., Wyber, R., et al. (2016) · Nature Reviews Disease Primers · doi:10.1038/nrdp.2015.84 · Cited by 706
Self-citationBecker, D. M., Tafoya, C. A., Becker, S. L., Kruger, G. H., Tafoya, M. J., & Becker, T. K. (2016) · Tropical Medicine & International Health · doi:10.1111/tmi.12657 · Cited by 208
Coffey, P. M., Ralph, A. P., & Krause, V. L. (2018) · PLOS Neglected Tropical Diseases · doi:10.1371/journal.pntd.0006577 · Cited by 178
Nascimento, B. R., Beaton, A. Z., Nunes, M. C. P., Diamantino, A. C., Carmo, G. A. L., Oliveira, K. K. B., Oliveira, C. M., Meira, Z. M. A., Castilho, S. R. T., Lopes, E. L. V., et al. (2016) · International Journal of Cardiology · doi:10.1016/j.ijcard.2016.06.088 · Cited by 81
Self-citationRheumatic heart disease echocardiographic screening: approaching practical and affordable solutions
Nascimento, B. R., Nunes, M. C. P., Lopes, E. L. V., Rezende, V. M. L. R., Landay, T., Ribeiro, A. L. P., Sable, C., & Beaton, A. Z. (2016) · Heart · doi:10.1136/heartjnl-2015-308635 · Cited by 43
Self-citation
Metadata
- Authors
- Beaton, A., Lu, J. C., Aliku, T., Dean, P., Gaur, L., Weinberg, J., Godown, J., Lwabi, P., Mirembe, G., Okello, E., Reese, A., Shrestha-Astudillo, A., Bradley-Hewitt, T., Scheel, J., Webb, C., McCarter, R., Ensing, G., & Sable, C.
- Venue
- European Heart Journal - Cardiovascular Imaging
- Publisher
- Oxford University Press (OUP)
- Published
- 2015-01-06
- Volume
- 16
- Issue
- 5
- Pages
- 475-482
- ISSN
- 2047-2404 (ISSN-L)
- 2047-2412
- OpenAlex
- W2152717159
- Cited by
- 116
- References
- 1
- FWCI
- 15.20
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.