The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Calcium distribution patterns of the aortic valve as a risk factor for the need of permanent pacemaker implantation after transcatheter aortic valve implantation
Abstract
New-onset conduction disturbances still represent a considerable problem after transcatheter aortic valve implantation (TAVI). The aim of this study was to identify calcification patterns with an elevated risk for permanent pacemaker implantation (PPI) after TAVI and investigate underlying mechanisms in an ex vivo setting. One hundred and sixty-two patients who underwent TAVI with the Edwards SAPIEN XT® or Medtronic CoreValve® at our institution were analysed. The calcium load of the device landing zone was quantified with 3mensio®, and calcium patterns with an elevated risk for PPI were identified. Ex vivo simulations of balloon valvuloplasty were performed in 3D-printed silicone annuli of patients matching the identified risk profile. Patients with a calcium load of the left coronary cusp (LCC) above 209 mm3 had a higher rate of PPI than patients below this threshold (16.7 vs. 2.6%, P = 0.003). Multivariate regression revealed pre-existing right bundle branch block (RBBB) and increased LCC calcification as independent predictors for PPI. Simulation of the TAVI procedure in a silicone annulus revealed an off-centreline shift of the valvuloplasty balloon and transcatheter heart valve away from the LCC towards the commissure between right- and non-coronary cusp. Pre-existing RBBB and elevated LCC calcification were identified as independent predictors for PPI. These two risk factors enabled us to distinguish between patients according to their risk for PPI after TAVI. Ex vivo simulations suggested an off-centreline shift of the balloon as a possible explanation.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Quantification of coronary artery calcium using ultrafast computed tomography
Agatston, A. S., Janowitz, W. R., Hildner, F. J., Zusmer, N. R., Viamonte, M., & Detrano, R. (1990) · Journal of the American College of Cardiology · doi:10.1016/0735-1097(90)90282-t · Cited by 7,786
2014 AHA/ACC Guideline for the Management of Patients With Valvular Heart Disease
Nishimura, R. A., Otto, C. M., Bonow, R. O., Carabello, B. A., Erwin, J. P., Guyton, R. A., O’Gara, P. T., Ruiz, C. E., Skubas, N. J., Sorajja, P., et al. (2014) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2014.02.536 · Cited by 3,523
Cited by
Blanke, P., Weir-McCall, J. R., Achenbach, S., Delgado, V., Hausleiter, J., Jilaihawi, H., Marwan, M., Nørgaard, B. L., Piazza, N., Schoenhagen, P., et al. (2019) · JACC: Cardiovascular Imaging · doi:10.1016/j.jcmg.2018.12.003 · Cited by 610
Auffret, V., Puri, R., Urena, M., Chamandi, C., Rodriguez-Gabella, T., Philippon, F., & Rodés-Cabau, J. (2017) · Circulation · doi:10.1161/circulationaha.117.028352 · Cited by 550
Blanke, P., Weir-McCall, J. R., Achenbach, S., Delgado, V., Hausleiter, J., Jilaihawi, H., Marwan, M., Norgaard, B. L., Piazza, N., Schoenhagen, P., et al. (2019) · Journal of Cardiovascular Computed Tomography · doi:10.1016/j.jcct.2018.11.008 · Cited by 543
Applications of 3D printing in cardiovascular diseases
Giannopoulos, A. A., Mitsouras, D., Yoo, S.-J., Liu, P. P., Chatzizisis, Y. S., & Rybicki, F. J. (2016) · Nature Reviews Cardiology · doi:10.1038/nrcardio.2016.170 · Cited by 421
Wood, D. A., Lauck, S. B., Cairns, J. A., Humphries, K. H., Cook, R., Welsh, R., Leipsic, J., Genereux, P., Moss, R., Jue, J., et al. (2019) · JACC: Cardiovascular Interventions · doi:10.1016/j.jcin.2018.12.020 · Cited by 259
Metadata
- Authors
- Fujita, B., Kütting, M., Seiffert, M., Scholtz, S., Egron, S., Prashovikj, E., Börgermann, J., Schäfer, T., Scholtz, W., Preuss, R., Gummert, J., Steinseifer, U., & Ensminger, S. M.
- Venue
- European Heart Journal – Cardiovascular Imaging
- Publisher
- Oxford University Press (OUP)
- Published
- 2016-01-12
- Volume
- 17
- Issue
- 12
- Pages
- 1385-1393
- ISSN
- 2047-2404 (ISSN-L)
- 2047-2412
- OpenAlex
- W2256005377
- Cited by
- 170
- References
- 2
- FWCI
- 15.69
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Calcium distribution patterns of the aortic valve as a risk factor for the need of permanent pacemaker implantation after transcatheter aortic valve implantation. https://app.cochat.ai/papers/10.1093/ehjci/jev343
- The paper
- Fujita, B., Kütting, M., Seiffert, M., Scholtz, S., Egron, S., Prashovikj, E., Börgermann, J., Schäfer, T., Scholtz, W., Preuss, R., Gummert, J., Steinseifer, U., & Ensminger, S. M. (2016). Calcium distribution patterns of the aortic valve as a risk factor for the need of permanent pacemaker implantation after transcatheter aortic valve implantation. European Heart Journal – Cardiovascular Imaging. https://doi.org/10.1093/ehjci/jev343
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.