The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
Normal range and usefulness of right ventricular systolic strain to detect subtle right ventricular systolic abnormalities in patients with heart failure: a multicentre study
Abstract
AIMS: The aim of the present multicentre study was to analyse a large cohort of healthy subjects and patients with a common condition such as heart failure (HF) with the purpose of determining the normal range and the usefulness of right ventricular (RV) systolic strain to detect subtle RV systolic abnormalities using 2D speckle-tracking echocardiography. METHODS AND RESULTS: We analysed 238 healthy subjects and a cohort of 642 patients characterized by asymptomatic patients (n = 216) and patients with HF with preserved (HFpEF) and reduced (HFrEF) ejection fraction (n = 218 and n = 208, respectively) prospectively included in 10 centres. The normal range of RV systolic strain analysing the healthy subjects was as follows: RV global strain -24.5 ± 3.8 and RV free wall strain -28.5 ± 4.8 (lowest expected value -17 and -19%, respectively). Concerning the ability of these myocardial parameters to detect subtle RV systolic abnormalities, RV global and free wall systolic strain were able to detect subtle RV longitudinal systolic abnormalities in a significant proportion of patients with HFrEF and to a lesser extent in HFpEF despite preserved tricuspid annular plane systolic excursion, tricuspid lateral annular peak systolic velocity by pulsed tissue Doppler imaging, and RV fractional area change. In addition, RV global and free wall systolic strain were significantly linked to the symptomatic status of the patients. CONCLUSIONS: The findings from this study provide important data regarding the normal range of RV global and free wall systolic strain and highlight the clinical relevance of these RV myocardial parameters to detect subtle RV systolic abnormalities in patients with HF.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
2013 ACCF/AHA Guideline for the Management of Heart Failure
Yancy, C. W., Jessup, M., Bozkurt, B., Butler, J., Casey, D. E., Drazner, M. H., Fonarow, G. C., Geraci, S. A., Horwich, T., Januzzi, J. L., et al. (2013) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2013.05.019 · Cited by 12,536
Recommendations for the Evaluation of Left Ventricular Diastolic Function by Echocardiography
Nagueh, S. F., Appleton, C. P., Gillebert, T. C., Marino, P. N., Oh, J. K., Smiseth, O. A., Waggoner, A. D., Flachskampf, F. A., Pellikka, P. A., & Evangelista, A. (2009) · Journal of the American Society of Echocardiography · doi:10.1016/j.echo.2008.11.023 · Cited by 4,367
Recommendations for the evaluation of left ventricular diastolic function by echocardiography
Nagueh, S. F., Appleton, C. P., Gillebert, T. C., Marino, P. N., Oh, J. K., Smiseth, O. A., Waggoner, A. D., Flachskampf, F. A., Pellikka, P. A., & Evangelisa, A. (2008) · European Journal of Echocardiography · doi:10.1093/ejechocard/jep007 · Cited by 3,351 · cited 4×
“septal or lateral mitral annular early-diastolic (e′) peak velocity ,8 or ,10 cm/s using TDI, respectively, or maximal LA volume index (LAVI) ≥34 mL/m(2).(21) HFrEF was defined in accordance with the guidelines on HF of the ESC: (a) clinical signs or symptoms of HF (i.”
MethodInfluential
Cited by
Gorter, T. M., van Veldhuisen, D. J., Bauersachs, J., Borlaug, B. A., Celutkiene, J., Coats, A. J. S., Crespo-Leiro, M. G., Guazzi, M., Harjola, V.-P., Heymans, S., et al. (2018) · European Journal of Heart Failure · doi:10.1002/ejhf.1029 · Cited by 389
Self-citationMorris, D. A., Belyavskiy, E., Aravind-Kumar, R., Kropf, M., Frydas, A., Braunauer, K., Marquez, E., Krisper, M., Lindhorst, R., Osmanoglou, E., et al. (2018) · JACC: Cardiovascular Imaging · doi:10.1016/j.jcmg.2017.07.029 · Cited by 388
Self-citation2- and 3-Dimensional Myocardial Strain in Cardiac Health and Disease
Voigt, J.-U., & Cvijic, M. (2019) · JACC: Cardiovascular Imaging · doi:10.1016/j.jcmg.2019.01.044 · Cited by 333
Gorter, T. M., Hoendermis, E. S., van Veldhuisen, D. J., Voors, A. A., Lam, C. S. P., Geelhoed, B., Willems, T. P., & van Melle, J. P. (2016) · European Journal of Heart Failure · doi:10.1002/ejhf.630 · Cited by 300
Metadata
- Authors
- Morris, D. A., Krisper, M., Nakatani, S., Köhncke, C., Otsuji, Y., Belyavskiy, E., Radha Krishnan, A. K., Kropf, M., Osmanoglou, E., Boldt, L.-H., Blaschke, F., Edelmann, F., Haverkamp, W., Tschöpe, C., Pieske-Kraigher, E., Pieske, B., & Takeuchi, M.
- Venue
- European Heart Journal – Cardiovascular Imaging
- Publisher
- Oxford University Press (OUP)
- Published
- 2016-02-11
- Volume
- 18
- Issue
- 2
- Pages
- 212-223
- ISSN
- 2047-2404 (ISSN-L)
- 2047-2412
- OpenAlex
- W2252944161
- Cited by
- 185
- References
- 3
- FWCI
- 10.46
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Normal range and usefulness of right ventricular systolic strain to detect subtle right ventricular systolic abnormalities in patients with heart failure: a multicentre study. https://app.cochat.ai/papers/10.1093/ehjci/jew011
- The paper
- Morris, D. A., Krisper, M., Nakatani, S., Köhncke, C., Otsuji, Y., Belyavskiy, E., Radha Krishnan, A. K., Kropf, M., Osmanoglou, E., Boldt, L.-H., Blaschke, F., Edelmann, F., Haverkamp, W., Tschöpe, C., Pieske-Kraigher, E., Pieske, B., & Takeuchi, M. (2017). Normal range and usefulness of right ventricular systolic strain to detect subtle right ventricular systolic abnormalities in patients with heart failure: a multicentre study. European Heart Journal – Cardiovascular Imaging. https://doi.org/10.1093/ehjci/jew011
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.