CoChat

Estimation of myocardial work from pressure–strain loops analysis: an experimental evaluation

Open access
Hubert, Arnaud, Le Rolle, Virginie, Leclercq, Christophe, Galli, Elena, Samset, Eigil, Casset, Cyrille, Mabo, Philippe, Hernandez, Alfredo, Donal, Erwan · 2018 · European Heart Journal - Cardiovascular Imaging
Cited by 220

The DOI matches its Crossref record; 20 of the 20 references it cites were found in a registry or an index.

Abstract

Purpose: The area of left ventricular (LV) pressure-strain loop (PSL) is used as an index of regional myocardial work. The purpose of the present work is to compare the main segmental PSL markers and the derived global work indices, when they are calculated using an estimated pressure signal or an observed pressure signal. Methods and results: In nine patients implanted with a bi-ventricular pace-maker (CRT), LV pressure was invasively measured in five conditions: CRT-off, LV-pacing, right ventricular-pacing and two different CRT-pacing. For each condition, systolic blood pressure was measured by brachial artery cuff-pressure and transthoracic echocardiography loops were recorded simultaneously. The error and relative root mean square error (rRMSE) between measured and estimated pressure were calculated for each patient and each configuration. Correlation coefficient (R2) and Bland-Altman (BA) analysis were performed for PSL area and work indices. A total of 43 different haemodynamic conditions were compared (774 segmental PSL). The global rRMSE between estimated and measured LV-pressure was 12.3 mmHg. The estimated and measured segmental LV-PSL were strongly correlated, with an R2 of 0.98. BA analysis shows that the mean bias for the estimation of segmental LV-PSL area is 86.0 mmHg.%. A significant bias effect with linearly increasing error with pressure values is observed. R2 ≥ 0.88 and a mean bias in BA analysis ≤41.4 mmHg.% was observed for the estimation of global myocardial work indices. Conclusion: The non-invasive estimation for LV pressure-strain loop area and the global myocardial work indices obtained from LV-PSL strongly correlates with invasive measurements.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1093/ehjci/jey024

Cites

20 of 20 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 20 references

Cited by

See all 220

Metadata

Authors
Hubert, A., Le Rolle, V., Leclercq, C., Galli, E., Samset, E., Casset, C., Mabo, P., Hernandez, A., & Donal, E.
Venue
European Heart Journal - Cardiovascular Imaging
Published
2018-02-26
Volume
19
Issue
12
Pages
1372-1379
ISSN
  • 2047-2404 (ISSN-L)
  • 2047-2412
OpenAlex
W2794331413
Cited by
220
References
20
FWCI
13.59
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Estimation of myocardial work from pressure–strain loops analysis: an experimental evaluation. https://app.cochat.ai/papers/10.1093/ehjci/jey024
The paper
Hubert, A., Le Rolle, V., Leclercq, C., Galli, E., Samset, E., Casset, C., Mabo, P., Hernandez, A., & Donal, E. (2018). Estimation of myocardial work from pressure–strain loops analysis: an experimental evaluation. European Heart Journal - Cardiovascular Imaging. https://doi.org/10.1093/ehjci/jey024

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.