The DOI matches its Crossref record; 67 of the 67 references it cites were found in a registry or an index.
Myocardial strain imaging: review of general principles, validation, and sources of discrepancies
Open accessAbstract
Myocardial tissue tracking imaging techniques have been developed for a more accurate evaluation of myocardial deformation (i.e. strain), with the potential to overcome the limitations of ejection fraction (EF) and to contribute, incremental to EF, to the diagnosis and prognosis in cardiac diseases. While most of the deformation imaging techniques are based on the similar principles of detecting and tracking specific patterns within an image, there are intra- and inter-imaging modality inconsistencies limiting the wide clinical applicability of strain. In this review, we aimed to describe the particularities of the echocardiographic and cardiac magnetic resonance deformation techniques, in order to understand the discrepancies in strain measurement, focusing on the potential sources of variation: related to the software used to analyse the data, to the different physics of image acquisition and the different principles of 2D vs. 3D approaches. As strain measurements are not interchangeable, it is highly desirable to work with validated strain assessment tools, in order to derive information from evidence-based data. There is, however, a lack of solid validation of the current tissue tracking techniques, as only a few of the commercial deformation imaging softwares have been properly investigated. We have, therefore, addressed in this review the neglected issue of suboptimal validation of tissue tracking techniques, in order to advocate for this matter.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Voigt, J.-U., Pedrizzetti, G., Lysyansky, P., Marwick, T. H., Houle, H., Baumann, R., Pedri, S., Ito, Y., Abe, Y., Metz, S., et al. (2015) · Journal of the American Society of Echocardiography · doi:10.1016/j.echo.2014.11.003 · Cited by 1,580
Human heart: tagging with MR imaging--a method for noninvasive assessment of myocardial motion.
Zerhouni, E. A., Parish, D. M., Rogers, W. J., Yang, A., & Shapiro, E. P. (1988) · Radiology · doi:10.1148/radiology.169.1.3420283 · Cited by 1,430
Noninvasive Myocardial Strain Measurement by Speckle Tracking Echocardiography
Amundsen, B. H., Helle-Valle, T., Edvardsen, T., Torp, H., Crosby, J., Lyseggen, E., Støylen, A., Ihlen, H., Lima, J. A. C., Smiseth, O. A., et al. (2006) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2005.10.040 · Cited by 1,252
MR imaging of motion with spatial modulation of magnetization.
Axel, L., & Dougherty, L. (1989) · Radiology · doi:10.1148/radiology.171.3.2717762 · Cited by 1,150
Geyer, H., Caracciolo, G., Abe, H., Wilansky, S., Carerj, S., Gentile, F., Nesser, H.-J., Khandheria, B., Narula, J., & Sengupta, P. P. (2010) · Journal of the American Society of Echocardiography · doi:10.1016/j.echo.2010.02.015 · Cited by 1,102
Urheim, S., Edvardsen, T., Torp, H., Angelsen, B., & Smiseth, O. A. (2000) · Circulation · doi:10.1161/01.cir.102.10.1158 · Cited by 1,078
Normal Ranges of Left Ventricular Strain: A Meta-Analysis
Yingchoncharoen, T., Agarwal, S., Popović, Z. B., & Marwick, T. H. (2013) · Journal of the American Society of Echocardiography · doi:10.1016/j.echo.2012.10.008 · Cited by 885
Myocardial strain imaging: how useful is it in clinical decision making?
Smiseth, O. A., Torp, H., Opdahl, A., Haugaa, K. H., & Urheim, S. (2016) · European Heart Journal · doi:10.1093/eurheartj/ehv529 · Cited by 861
Real-Time Strain Rate Imaging of the Left Ventricle by Ultrasound
Heimdal, A., Støylen, A., Torp, H., & Skjærpe, T. (1998) · Journal of the American Society of Echocardiography · doi:10.1016/s0894-7317(98)70151-8 · Cited by 850
Impaired Systolic Function by Strain Imaging in Heart Failure With Preserved Ejection Fraction
Kraigher-Krainer, E., Shah, A. M., Gupta, D. K., Santos, A., Claggett, B., Pieske, B., Zile, M. R., Voors, A. A., Lefkowitz, M. P., Packer, M., et al. (2014) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2013.09.052 · Cited by 756
Cited by
Hoffmann, F., Rabineau, J., Mehrkens, D., Gerlach, D. A., Moestl, S., Johannes, B. W., Caiani, E. G., Migeotte, P. F., Jordan, J., & Tank, J. (2021) · ESC Heart Failure · doi:10.1002/ehf2.13103 · Cited by 42
Avesani, M., Borrelli, N., Krupickova, S., Sabatino, J., Donne, G. D., Ibrahim, A., Piccinelli, E., Josen, M., Michielon, G., Fraisse, A., et al. (2020) · International Journal of Cardiology · doi:10.1016/j.ijcard.2020.07.026 · Cited by 26
Metadata
- Authors
- Amzulescu, M. S., De Craene, M., Langet, H., Pasquet, A., Vancraeynest, D., Pouleur, A. C., Vanoverschelde, J. L., & Gerber, B. L.
- Venue
- European Heart Journal - Cardiovascular Imaging
- Publisher
- Oxford University Press (OUP)
- Published
- 2019-03-21
- Volume
- 20
- Issue
- 6
- Pages
- 605-619
- ISSN
- 2047-2404 (ISSN-L)
- 2047-2412
- OpenAlex
- W2946080087
- Cited by
- 472
- References
- 67
- FWCI
- 40.59
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Myocardial strain imaging: review of general principles, validation, and sources of discrepancies. https://app.cochat.ai/papers/10.1093/ehjci/jez041
- The paper
- Amzulescu, M. S., De Craene, M., Langet, H., Pasquet, A., Vancraeynest, D., Pouleur, A. C., Vanoverschelde, J. L., & Gerber, B. L. (2019). Myocardial strain imaging: review of general principles, validation, and sources of discrepancies. European Heart Journal - Cardiovascular Imaging. https://doi.org/10.1093/ehjci/jez041
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.