Myocardial tissue tracking imaging techniques have been developed for a more accurate evaluation of myocardial deformation (i.e. strain), with the potential to overcome the limitations of ejection fraction (EF) and to contribute, incremental to EF, to the diagnosis and prognosis in cardiac diseases. While most of the deformation imaging techniques are based on the similar principles of detecting and tracking specific patterns within an image, there are intra- and inter-imaging modality inconsistencies limiting the wide clinical applicability of strain. In this review, we aimed to describe the particularities of the echocardiographic and cardiac magnetic resonance deformation techniques, in order to understand the discrepancies in strain measurement, focusing on the potential sources of variation: related to the software used to analyse the data, to the different physics of image acquisition and the different principles of 2D vs. 3D approaches. As strain measurements are not interchangeable, it is highly desirable to work with validated strain assessment tools, in order to derive information from evidence-based data. There is, however, a lack of solid validation of the current tissue tracking techniques, as only a few of the commercial deformation imaging softwares have been properly investigated. We have, therefore, addressed in this review the neglected issue of suboptimal validation of tissue tracking techniques, in order to advocate for this matter.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Voigt, J.-U., Pedrizzetti, G., Lysyansky, P., Marwick, T. H., Houle, H., Baumann, R., Pedri, S., Ito, Y., Abe, Y., Metz, S., et al. (2015) · Journal of the American Society of Echocardiography · doi:10.1016/j.echo.2014.11.003 · Cited by 1,580
Human heart: tagging with MR imaging--a method for noninvasive assessment of myocardial motion.
Zerhouni, E. A., Parish, D. M., Rogers, W. J., Yang, A., & Shapiro, E. P. (1988) · Radiology · doi:10.1148/radiology.169.1.3420283 · Cited by 1,430
Noninvasive Myocardial Strain Measurement by Speckle Tracking Echocardiography
Amundsen, B. H., Helle-Valle, T., Edvardsen, T., Torp, H., Crosby, J., Lyseggen, E., Støylen, A., Ihlen, H., Lima, J. A. C., Smiseth, O. A., et al. (2006) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2005.10.040 · Cited by 1,252
MR imaging of motion with spatial modulation of magnetization.
Axel, L., & Dougherty, L. (1989) · Radiology · doi:10.1148/radiology.171.3.2717762 · Cited by 1,150
Geyer, H., Caracciolo, G., Abe, H., Wilansky, S., Carerj, S., Gentile, F., Nesser, H.-J., Khandheria, B., Narula, J., & Sengupta, P. P. (2010) · Journal of the American Society of Echocardiography · doi:10.1016/j.echo.2010.02.015 · Cited by 1,102
Urheim, S., Edvardsen, T., Torp, H., Angelsen, B., & Smiseth, O. A. (2000) · Circulation · doi:10.1161/01.cir.102.10.1158 · Cited by 1,078
Normal Ranges of Left Ventricular Strain: A Meta-Analysis
Yingchoncharoen, T., Agarwal, S., Popović, Z. B., & Marwick, T. H. (2013) · Journal of the American Society of Echocardiography · doi:10.1016/j.echo.2012.10.008 · Cited by 885
Myocardial strain imaging: how useful is it in clinical decision making?
Smiseth, O. A., Torp, H., Opdahl, A., Haugaa, K. H., & Urheim, S. (2016) · European Heart Journal · doi:10.1093/eurheartj/ehv529 · Cited by 861
Real-Time Strain Rate Imaging of the Left Ventricle by Ultrasound
Heimdal, A., Støylen, A., Torp, H., & Skjærpe, T. (1998) · Journal of the American Society of Echocardiography · doi:10.1016/s0894-7317(98)70151-8 · Cited by 850
Impaired Systolic Function by Strain Imaging in Heart Failure With Preserved Ejection Fraction
Kraigher-Krainer, E., Shah, A. M., Gupta, D. K., Santos, A., Claggett, B., Pieske, B., Zile, M. R., Voors, A. A., Lefkowitz, M. P., Packer, M., et al. (2014) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2013.09.052 · Cited by 756
Head-to-Head Comparison of Global Longitudinal Strain Measurements among Nine Different Vendors
Farsalinos, K. E., Daraban, A. M., Ünlü, S., Thomas, J. D., Badano, L. P., & Voigt, J.-U. (2015) · Journal of the American Society of Echocardiography · doi:10.1016/j.echo.2015.06.011 · Cited by 698
Color Doppler Myocardial Imaging: A New Technique for the Assessment of Myocardial function
Sutherland, G. R., Stewart, M. J., Groundstroem, K. W. E., Moran, C. M., Fleming, A., Guell-Peris, F. J., Riemersma, R. A., Fenn, L. N., Fox, K. A. A., & McDicken, W. N. (1994) · Journal of the American Society of Echocardiography · doi:10.1016/s0894-7317(14)80001-1 · Cited by 617
A Test in Context: Myocardial Strain Measured by Speckle-Tracking Echocardiography
Collier, P., Phelan, D., & Klein, A. (2017) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2016.12.012 · Cited by 531
Edvardsen, T., Gerber, B. L., Garot, J., Bluemke, D. A., Lima, J. A. C., & Smiseth, O. A. (2002) · Circulation · doi:10.1161/01.cir.0000019907.77526.75 · Cited by 523
Self-citationPerk, G., Tunick, P. A., & Kronzon, I. (2007) · Journal of the American Society of Echocardiography · doi:10.1016/j.echo.2006.08.023 · Cited by 501
Shah, A. M., Claggett, B., Sweitzer, N. K., Shah, S. J., Anand, I. S., Liu, L., Pitt, B., Pfeffer, M. A., & Solomon, S. D. (2015) · Circulation · doi:10.1161/circulationaha.115.015884 · Cited by 478
Tissue Tracking Technology for Assessing Cardiac Mechanics
Claus, P., Omar, A. M. S., Pedrizzetti, G., Sengupta, P. P., & Nagel, E. (2015) · JACC: Cardiovascular Imaging · doi:10.1016/j.jcmg.2015.11.001 · Cited by 439
Pedrizzetti, G., Claus, P., Kilner, P. J., & Nagel, E. (2016) · Journal of Cardiovascular Magnetic Resonance · doi:10.1186/s12968-016-0269-7 · Cited by 416
Assessment of Passive Elastic Stiffness for Isolated Heart Muscle and the Intact Heart
MIRSKY, I., & PARMLEY, W. W. (1973) · Circulation Research · doi:10.1161/01.res.33.2.233 · Cited by 400
Global Longitudinal Strain to Predict Mortality in Patients With Acute Heart Failure
Park, J. J., Park, J.-B., Park, J.-H., & Cho, G.-Y. (2018) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2018.02.064 · Cited by 400
Hor, K. N., Gottliebson, W. M., Carson, C., Wash, E., Cnota, J., Fleck, R., Wansapura, J., Klimeczek, P., Al-Khalidi, H. R., Chung, E. S., et al. (2010) · JACC: Cardiovascular Imaging · doi:10.1016/j.jcmg.2009.11.006 · Cited by 379
Korinek, J., Wang, J., Sengupta, P. P., Miyazaki, C., Kjaergaard, J., McMahon, E., Abraham, T. P., & Belohlavek, M. (2005) · Journal of the American Society of Echocardiography · doi:10.1016/j.echo.2005.03.024 · Cited by 349
Langeland, S., D’hooge, J., Wouters, P. F., Leather, H. A., Claus, P., Bijnens, B., & Sutherland, G. R. (2005) · Circulation · doi:10.1161/circulationaha.105.554006 · Cited by 331
Muraru, D., Niero, A., Rodríguez‐Zanella, H., Cherata, D. A., & Badano, L. P. (2018) · Cardiovascular Diagnosis and Therapy · doi:10.21037/cdt.2017.06.01 · Cited by 306
Augustine, D., Lewandowski, A. J., Lazdam, M., Rai, A., Francis, J., Myerson, S., Noble, A., Becher, H., Neubauer, S., Petersen, S. E., et al. (2013) · Journal of Cardiovascular Magnetic Resonance · doi:10.1186/1532-429x-15-8 · Cited by 285
Ejection Fraction: Misunderstood and Overrated (Changing the Paradigm in Categorizing Heart Failure)
Konstam, M. A., & Abboud, F. M. (2017) · Circulation · doi:10.1161/circulationaha.116.025795 · Cited by 276
Knackstedt, C., Bekkers, S. C. A. M., Schummers, G., Schreckenberg, M., Muraru, D., Badano, L. P., Franke, A., Bavishi, C., Omar, A. M. S., & Sengupta, P. P. (2015) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2015.07.052 · Cited by 262
Pirat, B., Khoury, D. S., Hartley, C. J., Tiller, L., Rao, L., Schulz, D. G., Nagueh, S. F., & Zoghbi, W. A. (2008) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2007.10.029 · Cited by 260
Delgado, V., Tops, L. F., van Bommel, R. J., van der Kley, F., Marsan, N. A., Klautz, R. J., Versteegh, M. I. M., Holman, E. R., Schalij, M. J., & Bax, J. J. (2009) · European Heart Journal · doi:10.1093/eurheartj/ehp351 · Cited by 260
Cho, G.-Y., Chan, J., Leano, R., Strudwick, M., & Marwick, T. H. (2006) · The American Journal of Cardiology · doi:10.1016/j.amjcard.2005.12.063 · Cited by 255
Garot, J., Bluemke, D. A., Osman, N. F., Rochitte, C. E., McVeigh, E. R., Zerhouni, E. A., Prince, J. L., & Lima, J. A. C. (2000) · Circulation · doi:10.1161/01.cir.101.9.981 · Cited by 246
Reant, P., Labrousse, L., Lafitte, S., Bordachar, P., Pillois, X., Tariosse, L., Bonoron-Adele, S., Padois, P., Deville, C., Roudaut, R., et al. (2008) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2007.07.088 · Cited by 237
Andre, F., Steen, H., Matheis, P., Westkott, M., Breuninger, K., Sander, Y., Kammerer, R., Galuschky, C., Giannitsis, E., Korosoglou, G., et al. (2015) · Journal of Cardiovascular Magnetic Resonance · doi:10.1186/s12968-015-0123-3 · Cited by 217
Validation of 3-Dimensional Speckle Tracking Imaging to Quantify Regional Myocardial Deformation
Seo, Y., Ishizu, T., Enomoto, Y., Sugimori, H., Yamamoto, M., Machino, T., Kawamura, R., & Aonuma, K. (2009) · Circulation Cardiovascular Imaging · doi:10.1161/circimaging.109.858480 · Cited by 210
Clark, N. R., Reichek, N., Bergey, P., Hoffman, E. A., Brownson, D., Palmon, L., & Axel, L. (1991) · Circulation · doi:10.1161/01.cir.84.1.67 · Cited by 190
Schuster, A., Stahnke, V., Unterberg‐Buchwald, C., Kowallick, J. T., Lamata, P., Steinmetz, M., Kutty, S., Faßhauer, M., Staab, W., Sohns, J. M. S., et al. (2015) · Clinical Radiology · doi:10.1016/j.crad.2015.05.006 · Cited by 189
Bansal, M., Cho, G.-Y., Chan, J., Leano, R., Haluska, B. A., & Marwick, T. H. (2008) · Journal of the American Society of Echocardiography · doi:10.1016/j.echo.2008.09.021 · Cited by 186
Velocity and deformation imaging for the assessment of myocardial dysfunction
Bijnens, B. H., Cikes, M., Claus, P., & Sutherland, G. R. (2008) · European Journal of Echocardiography · doi:10.1093/ejechocard/jen323 · Cited by 184
Kocabay, G., Muraru, D., Peluso, D., Cucchini, U., Mihaila, S. B., Jose, S. P., Denas, G., Iliceto, S., Vinereanu, D., & Badano, L. P. (2014) · Revista Española de Cardiología (English Edition) · doi:10.1016/j.rec.2013.12.009 · Cited by 174
Lima, J. A. C., Jeremy, R., Guier, W., Bouton, S., Zerhouni, E. A., McVeigh, E., Buchalter, M. B., Weisfeldt, M. L., Shapiro, E. P., & Weiss, J. L. (1993) · Journal of the American College of Cardiology · doi:10.1016/0735-1097(93)90397-j · Cited by 163
Kocabay, G., Muraru, D., Peluso, D., Cucchini, U., Mihaila, S. B., Jose, S. P., Denas, G., Iliceto, S., Vinereanu, D., & Badano, L. P. (2014) · Revista Española de Cardiología · doi:10.1016/j.recesp.2013.12.011 · Cited by 156
Noninvasive measurement of transmural gradients in myocardial strain with MR imaging.
McVeigh, E. R., & Zerhouni, E. A. (1991) · Radiology · doi:10.1148/radiology.180.3.1871278 · Cited by 154
Choi, E., Rosen, B. D., Fernandes, V., Yan, R. T., Yoneyama, K., Donekal, S., Opdahl, A., de Almeida, A. L. C., Wu, C. O., Gomes, A. S., et al. (2013) · European Heart Journal · doi:10.1093/eurheartj/eht133 · Cited by 154
Yang, H., Marwick, T. H., Fukuda, N., Oe, H., Saito, M., Thomas, J. D., & Negishi, K. (2015) · Journal of the American Society of Echocardiography · doi:10.1016/j.echo.2014.12.009 · Cited by 135
Cheng, S., Larson, M. G., McCabe, E. L., Osypiuk, E., Lehman, B. T., Stanchev, P., Aragam, J., Benjamin, E. J., Solomon, S. D., & Vasan, R. S. (2013) · Circulation: Cardiovascular Imaging · doi:10.1161/circimaging.112.000627 · Cited by 127
Assessment of global and regional myocardial function in the mouse using cine and tagged MRI
Zhou, R., Pickup, S., Glickson, J. D., Scott, C. H., & Ferrari, V. A. (2003) · Magnetic Resonance in Medicine · doi:10.1002/mrm.10423 · Cited by 112
Kleijn, S. A., Pandian, N. G., Thomas, J. D., de Isla, L. P., Otto Kamp, B., Züber, M., Nihoyannopoulos, P., Forster, T., Nesser, H. J., Geibel, A., et al. (2014) · European Heart Journal - Cardiovascular Imaging · doi:10.1093/ehjci/jeu213 · Cited by 110
Amundsen, B. H., Crosby, J., Steen, P. A., Torp, H. G., Slørdahl, S. A., & Støylen, A. (2008) · European Heart Journal - Cardiovascular Imaging · doi:10.1093/ejechocard/jen201 · Cited by 109
Badano, L. P., Cucchini, U., Muraru, D., Nono, O. H. H. A., Sarais, C., & Iliceto, S. (2012) · European Heart Journal - Cardiovascular Imaging · doi:10.1093/ehjci/jes184 · Cited by 106
Barbier, P., Mirea, O., Cefalù, C., Maltagliati, A. C., Savioli, G., & Guglielmo, M. (2015) · European Heart Journal - Cardiovascular Imaging · doi:10.1093/ehjci/jeu274 · Cited by 105
Heyde, B., Jasaitytė, R., Barbosa, D., Robesyn, V., Bouchez, S., Wouters, P. F., Maes, F., Claus, P., & D’hooge, J. (2012) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2012.2230114 · Cited by 87
Langeland, S., Wouters, P. F., Claus, P., Leather, H. A., Bijnens, B. H., Sutherland, G. R., Rademakers, F. E., & D’hooge, J. (2006) · Ultrasound in Medicine & Biology · doi:10.1016/j.ultrasmedbio.2006.06.021 · Cited by 81
Toyoda, T., Baba, H., Akasaka, T., Akiyama, M., Neishi, Y., Tomita, J., Sukmawan, R., Koyama, Y., Watanabe, N., Tamano, S., et al. (2004) · Journal of the American Society of Echocardiography · doi:10.1016/j.echo.2004.07.010 · Cited by 78
Cheng, S. C., McCabe, E. L., Larson, M. G., Merz, A. A., Osypiuk, E. W., Lehman, B. T., Stantchev, P., Aragam, J. R., Solomon, S. D., Benjamin, E. J., et al. (2015) · Journal of the American Heart Association · doi:10.1161/jaha.115.002071 · Cited by 78
Singh, A., Steadman, C. D., Khan, J. N., Horsfield, M. A., Bekele, S., Nazir, S. A., Kanagala, P., Masca, N. G. D., Clarysse, P., & McCann, G. P. (2014) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.24625 · Cited by 76
Alessandrini, M., Chakraborty, B., Heyde, B., Bernard, O., Craene, M. D., Sermesant, M., & D’hooge, J. (2017) · IEEE Transactions on Ultrasonics Ferroelectrics and Frequency Control · doi:10.1109/tuffc.2017.2786300 · Cited by 76
Giuşcă, S., Korosoglou, G., Zieschang, V., Stoiber, L., Schnackenburg, B., Stehning, C., Gebker, R., Pieske, B. M., Schuster, A., Backhaus, S. J., et al. (2018) · Scientific Reports · doi:10.1038/s41598-018-32226-3 · Cited by 75
3D Strain Assessment in Ultrasound (Straus): A Synthetic Comparison of Five Tracking Methodologies
Craene, M. D., Marchesseau, S., Heyde, B., Gao, H., Alessandrini, M., Bernard, O., Piella, G., Porras, A. R., Tautz, L., Hennemuth, A., et al. (2013) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2013.2261823 · Cited by 72
Amzulescu, M. S., Langet, H., Saloux, É., Manrique, A., Boileau, L., Slimani, A., Allain, P., Roy, C., de Meester, C., Pasquet, A., et al. (2017) · Circulation Cardiovascular Imaging · doi:10.1161/circimaging.117.006530 · Cited by 65
Self-citationLiu, W., Chen, J., Ji, S., Allen, J. S., Bayly, P. V., Wickline, S. A., & Yu, X. (2004) · Magnetic Resonance in Medicine · doi:10.1002/mrm.20276 · Cited by 62
Heyde, B., Cygan, S., Choi, H. F., Leśniak-Plewińska, B., Barbosa, D., Elen, A., Claus, P., Loeckx, D., Kałużyński, K., & D’hooge, J. (2012) · IEEE Transactions on Ultrasonics Ferroelectrics and Frequency Control · doi:10.1109/tuffc.2012.2245 · Cited by 58
Shiino, K., Yamada, A., Ischenko, M., Khandheria, B. K., Hudaverdi, M., Speranza, V., Harten, M., Benjamin, A., Hamilton-Craig, C. R., Platts, D. G., et al. (2016) · European Heart Journal - Cardiovascular Imaging · doi:10.1093/ehjci/jew120 · Cited by 53
Zhou, Y., Giffard‐Roisin, S., Craene, M. D., Camarasu-Pop, S., D’hooge, J., Alessandrini, M., Friboulet, D. P., Sermesant, M., & Bernard, O. (2017) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2017.2708159 · Cited by 47
Heyde, B., Bouchez, S., Thieren, S., Vandenheuvel, M., Jasaitytė, R., Barbosa, D., Claus, P., Maes, F., Wouters, P. F., & D’hooge, J. (2013) · Ultrasound in Medicine & Biology · doi:10.1016/j.ultrasmedbio.2013.02.463 · Cited by 40
Thomas, D. H., Ferrari, V. A., Janik, M. J., Kim, D. H., Pickup, S., Glickson, J. D., & Zhou, R. (2004) · Magnetic Resonance Materials in Physics Biology and Medicine · doi:10.1007/s10334-004-0051-y · Cited by 32
Accuracy of Real-Time Single- and Multi-Beat 3-D Speckle Tracking Echocardiography In Vitro
Hjertaas, J. J., Fosså, H., Dybdahl, G. L., Grüner, R., Lunde, P., & Matre, K. (2013) · Ultrasound in Medicine & Biology · doi:10.1016/j.ultrasmedbio.2013.01.010 · Cited by 22
Zhou, X. H., Thavendiranathan, P., Chen, Y., Cheng, L., Qian, Z., Liu, S., Houle, H. C., Zhi, G., & Vannan, M. A. (2015) · Journal of the American Society of Echocardiography · doi:10.1016/j.echo.2015.07.027 · Cited by 16
Cited by
Obesity cardiomyopathy: evidence, mechanisms, and therapeutic implications
Ren, J., Wu, N. N., Wang, S., Sowers, J. R., & Zhang, Y. (2021) · Physiological Reviews · doi:10.1152/physrev.00030.2020 · Cited by 370
Hoffmann, F., Rabineau, J., Mehrkens, D., Gerlach, D. A., Moestl, S., Johannes, B. W., Caiani, E. G., Migeotte, P. F., Jordan, J., & Tank, J. (2021) · ESC Heart Failure · doi:10.1002/ehf2.13103 · Cited by 42
“magnetic resonance imaging (MRI) may further improve risk prediction.(5) Head‐down‐tilt bed rest models cardiovascular deconditioning in weightlessness.”
BackgroundAvesani, M., Borrelli, N., Krupickova, S., Sabatino, J., Donne, G. D., Ibrahim, A., Piccinelli, E., Josen, M., Michielon, G., Fraisse, A., et al. (2020) · International Journal of Cardiology · doi:10.1016/j.ijcard.2020.07.026 · Cited by 26
Metadata
- Authors
- Amzulescu, M. S., De Craene, M., Langet, H., Pasquet, A., Vancraeynest, D., Pouleur, A. C., Vanoverschelde, J. L., & Gerber, B. L.
- Venue
- European Heart Journal - Cardiovascular Imaging
- Publisher
- Oxford University Press (OUP)
- Published
- 2019-03-21
- Volume
- 20
- Issue
- 6
- Pages
- 605-619
- ISSN
- 2047-2404 (ISSN-L)
- 2047-2412
- OpenAlex
- W2946080087
- Cited by
- 472
- References
- 67
- FWCI
- 40.59
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.