CoChat

Early and late failure of tissue-engineered pulmonary valve conduits used for right ventricular outflow tract reconstruction in patients with congenital heart disease

Open access
Perri, G., Polito, A., Esposito, C., Albanese, S. B., Francalanci, P., Pongiglione, G., Carotti, A. · 2012 · European Journal of Cardio-Thoracic Surgery
Cited by 84

The DOI matches its Crossref record.

Abstract

OBJECTIVES: To identify factors associated with the surgical outcome in patients undergoing right ventricular outflow tract reconstruction (RVOTR) using decellularized tissue-engineered pulmonary valve conduits (TEPVc) and to study their safety and longevity. METHODS: From April 2006 to April 2010, 93 patients underwent either palliative or corrective RVOTR using Matrix P (37) and Matrix P Plus (56) xenogenic decellularized TEPVc (size range 11-27 mm). Median age and weight at operation were 20 (0.16-290) months and 10.15 (2.65-86) kg respectively. Primary and redo surgery occurred in 40 and 60% of cases, respectively. Eighty-eight patients (94.6%) received conduit implantation in the framework of corrective surgery, whereas in 5 (5.4%) a palliative procedure was undertaken. Follow-up was complete in 91% of patients, with a median duration of 12 months (range: 2 days-51 months). Data analysis included diagnosis, type of surgery (palliative vs. corrective) and age at surgery. Predetermined primary outcomes were represented by conduit failure or dysfunction. RESULTS: Two patients with Matrix P and two with Matrix P Plus died in the early post-operatively phase (4.3%). None of the deaths were conduit-related. One patient died at conduit replacement. Thirty-three patients (35.5%) experienced conduit failure whereas conduit dysfunction occurred in 27 patients (29%). Two-year freedom from conduit failure and dysfunction was 60.2% (95% CI: 50.1-69.6) and 77.4% (95% CI: 67.9-84.7), respectively. Reasons for failure were conduit stenosis in 20 cases (61%), pseudoaneurysm in 3 (9%), conduit dilatation (>50% of original diameter) in 2 (6%), stenosis of distal anastomosis involving pulmonary bifurcation in 6 (18%) and allograft dissection in 2 (6%). Histological examination showed inflammatory giant-type cells in the presence of a poor autologous cell seeding in all explanted specimens. Univariate and multivariate analyses showed an association between age at surgery ≤1 year and conduit dysfunction (adjusted HR: 2.29; 95% CI: 1.01-5.20, P = 0.04). CONCLUSIONS: Compared with the other conduit for RVOTR Matrix conduits showed a high incidence of failure. Our results suggest that the use of Matrix conduits for RVOTR should be considered with caution.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1093/ejcts/ezr221

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 84

Metadata

Authors
Perri, G., Polito, A., Esposito, C., Albanese, S. B., Francalanci, P., Pongiglione, G., & Carotti, A.
Venue
European Journal of Cardio-Thoracic Surgery
Published
2012-01-04
Volume
41
Issue
6
Pages
1320-1325
ISSN
  • 1010-7940 (ISSN-L)
  • 1873-734X
OpenAlex
W2125850574
Cited by
84
References
0
FWCI
6.25
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Early and late failure of tissue-engineered pulmonary valve conduits used for right ventricular outflow tract reconstruction in patients with congenital heart disease. https://app.cochat.ai/papers/10.1093/ejcts/ezr221
The paper
Perri, G., Polito, A., Esposito, C., Albanese, S. B., Francalanci, P., Pongiglione, G., & Carotti, A. (2012). Early and late failure of tissue-engineered pulmonary valve conduits used for right ventricular outflow tract reconstruction in patients with congenital heart disease. European Journal of Cardio-Thoracic Surgery. https://doi.org/10.1093/ejcts/ezr221

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.