Aortic valve calcium scoring is a predictor of significant paravalvular aortic insufficiency in transapical-aortic valve implantation
Open accessThe DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.
Abstract
OBJECTIVE: Transapical-aortic valve implantation (TA-AVI) has evolved as routine for selected high-risk patients. However, paravalvular leaks >1+ remain an unsolved issue using current generations of transcatheter valve devices. The purpose of this study was to investigate the impact of native aortic valve calcification on paravalvular leaks and outcomes using the Edwards SAPIEN™ prosthesis. METHODS: One hundred and twenty consecutive patients (out of 307 TA-AVIs) with preoperative computed tomography aged 82.6 ± 6.2 years, 75.0% female were included. Implanted prosthetic valve sizes were 23 mm (n = 31) and 26 mm (n = 89), respectively. Mean logistic European System for Cardiac Operative Risk Evaluation-Score was 30.1 ± 15.5% and mean Society of Thoracic Surgeons-Score was 12.8 ± 7.9%. Electrocardiographic (ECG)-gated cardiac computed tomography allowed to quantify the amount of calcification of aortic valve leaflets using a scoring analogous to the Agatston calcium scoring of coronary arteries [Aortic Valve Calcium Scoring (AVCS)]. Paravalvular leaks were assessed intraoperatively by echocardiography and root angiography. RESULTS: All valves were implanted successfully. The mean AVCS in patients without paravalvular leaks (n = 66) was 2704 ± 1510; with mild paravalvular leaks (n = 31) was 3804 ± 2739 (P = 0.05); and with moderate paravalvular leaks (n = 4) was 7387 ± 1044 (P = 0.002). There was a significant association between the AVCS and paravalvular leaks [odds ratio (OR; per AVCS of 1000), 11.38; 95% confidence interval (CI) 2.33-55.53; P = 0.001)] and a trend towards a higher incidence of new pacemaker implantation (OR 1.27; 95% CI 0.85-1.89; P = 0.26). No association was found to 30-day mortality, major cardiac events and stroke rate (OR 1.05; 95% CI 0.84-1.32; P = 0.68; OR 0.92; 95% CI 0.68-1.25; P = 0.57 and OR 0.90; 95% CI 0.41-1.96; P = 0.79, respectively). Overall 30-day mortality was 14.2%. CONCLUSION: Severe native valve calcifications are predictive for postoperative relevant paravalvular leak. AVCS prior to TA-AVI might serve as an additional tool to reconsider the TAVI indication to reduce the risk of paravalvular leaks especially in so-called operable patients.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Quantification of coronary artery calcium using ultrafast computed tomography
Agatston, A. S., Janowitz, W. R., Hildner, F. J., Zusmer, N. R., Viamonte, M., & Detrano, R. (1990) · Journal of the American College of Cardiology · doi:10.1016/0735-1097(90)90282-t · Cited by 7,786 · cited 1×
“[11] using a detection threshold of 130 HU.”
MethodTranscatheter Aortic-Valve Implantation for Aortic Stenosis in Patients Who Cannot Undergo Surgery
Leon, M. B., Smith, C. R., Mack, M., Miller, D. C., Moses, J. W., Svensson, L. G., Tuzcu, E. M., Webb, J. G., Fontana, G. P., Makkar, R. R., et al. (2010) · New England Journal of Medicine · doi:10.1056/nejmoa1008232 · Cited by 7,205
Transcatheter versus Surgical Aortic-Valve Replacement in High-Risk Patients
Smith, C. R., Leon, M. B., Mack, M. J., Miller, D. C., Moses, J. W., Svensson, L. G., Tuzcu, E. M., Webb, J. G., Fontana, G. P., Makkar, R. R., et al. (2011) · New England Journal of Medicine · doi:10.1056/nejmoa1103510 · Cited by 6,345 · cited 15×
“symptoms [1, 2], TAVI is also associated with the presence of a paravavular leak in up to 60% of patients [3].”
BackgroundInfluentialMoat, N. E., Ludman, P., de Belder, M. A., Bridgewater, B., Cunningham, A. D., Young, C. P., Thomas, M., Kovac, J., Spyt, T., MacCarthy, P. A., et al. (2011) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2011.08.050 · Cited by 884 · cited 1×
“symptoms [1, 2], TAVI is also associated with the presence of a paravavular leak in up to 60% of patients [3].”
Background
Cited by
Two-Year Outcomes after Transcatheter or Surgical Aortic-Valve Replacement
Kodali, S. K., Williams, M. R., Smith, C. R., Svensson, L. G., Webb, J. G., Makkar, R. R., Fontana, G. P., Dewey, T. M., Thourani, V. H., Pichard, A. D., et al. (2012) · New England Journal of Medicine · doi:10.1056/nejmoa1200384 · Cited by 2,282
Mack, M. J., Leon, M. B., Smith, C. R., Miller, D. C., Moses, J. W., Tuzcu, E. M., Webb, J. G., Douglas, P. S., Anderson, W. N., Blackstone, E. H., et al. (2015) · The Lancet · doi:10.1016/s0140-6736(15)60308-7 · Cited by 1,739
Paravalvular Leak After Transcatheter Aortic Valve Replacement
Généreux, P., Head, S. J., Hahn, R., Daneault, B., Kodali, S., Williams, M. R., van Mieghem, N. M., Alu, M. C., Serruys, P. W., Kappetein, A. P., et al. (2013) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2012.08.1039 · Cited by 447
Zoghbi, W. A., Asch, F. M., Bruce, C., Gillam, L. D., Grayburn, P. A., Hahn, R. T., Inglessis, I., Islam, A. M., Lerakis, S., Little, S. H., et al. (2019) · Journal of the American Society of Echocardiography · doi:10.1016/j.echo.2019.01.003 · Cited by 439
Aggarwal, S. R., Clavel, M.-A., Messika-Zeitoun, D., Cueff, C., Malouf, J., Araoz, P. A., Mankad, R., Michelena, H., Vahanian, A., & Enriquez-Sarano, M. (2013) · Circulation: Cardiovascular Imaging · doi:10.1161/circimaging.112.980052 · Cited by 280
“in transcatheter aortic valve implantation to predict aortic regurgitation after the procedure.(48) However, our study emphasizes the necessity to interpret differently the link between AVC load”
BackgroundKhalique, O. K., Hahn, R. T., Gada, H., Nazif, T. M., Vahl, T. P., George, I., Kalesan, B., Forster, M., Williams, M. B., Leon, M. B., et al. (2014) · JACC: Cardiovascular Interventions · doi:10.1016/j.jcin.2014.03.007 · Cited by 227
Metadata
- Authors
- Haensig, M., Lehmkuhl, L., Rastan, A. J., Kempfert, J., Mukherjee, C., Gutberlet, M., Holzhey, D. M., & Mohr, F. W.
- Venue
- European Journal of Cardio-Thoracic Surgery
- Publisher
- Oxford University Press (OUP)
- Published
- 2012-01-12
- Volume
- 41
- Issue
- 6
- Pages
- 1234-1241
- ISSN
- 1010-7940 (ISSN-L)
- 1873-734X
- OpenAlex
- W2103775378
- Cited by
- 138
- References
- 4
- FWCI
- 14.00
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.