Systolic time intervals
Abstract
The systolic time intervals (STI) offer temporal description of the sequential phases of cardiac cycle which are influenced physiologically by the same variables as affect other measures of left ventricular (LV) performance. The STI hence offer a measure of ventricular function which augments other measures of ventricular performance. Because of the extreme sensitivity of this variable and the ease of its measurement the STI are well suited for studying the effect of pharmacologic agents upon the heart.
Integrity signals
Registry
Cites
Statistics
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
The ratio between PEP and LVET is a good indicator of left ventricular dysfunction.
“As a result, it has been proposed that the ratio between PEP and LVET is a good indicator of LV dysfunction.”
From A Chest‐Conformable, Wireless Electro‐Mechanical E‐Tattoo for Measuring Multiple Cardiac Time Intervals (2023) · cites this paper as [13]
Cited by
Sorted by citations
O’Rourke, M. F., Pauca, A. L., & Jiang, X. (2001) · British Journal of Clinical Pharmacology · doi:10.1046/j.0306-5251.2001.01400.x · Cited by 640 · see citing works
Réant, P., Dijos, M., Donal, E., Mignot, A., Ritter, P., Bordachar, P., Santos, P. D. D., Leclercq, C., Roudaut, R., Habib, G., et al. (2010) · European Journal of Echocardiography · doi:10.1093/ejechocard/jeq084 · Cited by 122 · see citing works
Blood Pressure Estimation Using Pulse Transit Time From Bioimpedance and Continuous Wave Radar
Buxi, D., Jean-Michel, R., & Yuce, M. R. (2016) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2016.2582472 · Cited by 121 · see citing works
“This coincides with the dichrotic notch, which is associated with aortic valve closure [14], [49].”
BackgroundCardim, N. M., Oliveira, A. G., Longo, S., Ferreira, T. C., Pereira, A., dos Reis, R. P., & Correia, J. M. (2003) · Journal of the American Society of Echocardiography · doi:10.1067/mje.2003.13 · Cited by 115 · see citing works
Hole, T., Vegsundvåg, J., & Skjærpe, T. (2003) · Echocardiography · doi:10.1046/j.1540-8175.2003.03020.x · Cited by 108 · see citing works
Induced hypervolemia, cardiac function, &OV0312;O2max, and performance of elite cyclists
Warburton, D. E. R., Gledhill, N., Jamnik, V., KRIP, B., & Card, N. (1999) · Medicine & Science in Sports & Exercise · doi:10.1097/00005768-199906000-00007 · Cited by 96 · see citing works
Marik, P. E., Pendelton, J. E., & Smith, R. J. (1997) · Critical Care Medicine · doi:10.1097/00003246-199709000-00023 · Cited by 87 · see citing works
The significance of left ventricular ejection time in heart failure with reduced ejection fraction
Alhakak, A. S., Teerlink, J. R., Lindenfeld, J. M., Böhm, M., Rosano, G. M. C., & Biering‐Sørensen, T. (2021) · European Journal of Heart Failure · doi:10.1002/ejhf.2125 · Cited by 81 · see citing works
Dehkordi, P., Khosrow-Khavar, F., Rienzo, M. D., Inan, O. T., Schmidt, S. E., Blaber, A. P., Sørensen, K., Struijk, J. J., Zakeri, V., Lombardi, P., et al. (2019) · Frontiers in Physiology · doi:10.3389/fphys.2019.01057 · Cited by 82 · see citing works
Biering-Sørensen, T., Querejeta Roca, G., Hegde, S. M., Shah, A. M., Claggett, B., Mosley, T. H., Butler, K. R., & Solomon, S. D. (2018) · European Journal of Heart Failure · doi:10.1002/ejhf.928 · Cited by 76 · see citing works
Systolic Time Intervals and New Measurement Methods
Tavakolian, K. (2016) · Cardiovascular Engineering and Technology · doi:10.1007/s13239-016-0262-1 · Cited by 69 · see citing works
Salvi, P., Palombo, C., Salvi, G. M., Labat, C., Parati, G., & Bénétos, A. (2013) · Journal of Applied Physiology · doi:10.1152/japplphysiol.00475.2013 · Cited by 63 · see citing works
Chan, G. S. H., Middleton, P. M., Celler, B. G., Wang, L., & Lovell, N. H. (2007) · Journal of Clinical Monitoring and Computing · doi:10.1007/s10877-007-9086-8 · Cited by 62 · see citing works
Aggarwal, M., Grady, R. M., Choudhry, S., et al. (2018) · Circulation Cardiovascular Imaging · doi:10.1161/circimaging.118.007964 · Cited by 57 · see citing works
Analyzing Seismocardiogram Cycles to Identify the Respiratory Phases
Zakeri, V., Akhbardeh, A., Alamdari, N., et al. (2016) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2016.2621037 · Cited by 53 · see citing works
Non-Invasive Cardiac Output Monitoring by Aortic Blood Flow Measurement With the Dynemo 3000
Boulnois, J.-L. G., & Pechoux, T. (2000) · Journal of Clinical Monitoring and Computing · doi:10.1023/a:1009902517388 · Cited by 52 · see citing works
Fellahi, J.-L., Caille, V., Charron, C., et al. (2009) · Anesthesia & Analgesia · doi:10.1213/ane.0b013e31819cd97e · Cited by 51 · see citing works
Pollonini, L., Rajan, N., Xu, S., Madala, S., & Dacso, C. C. (2010) · Journal of Medical Systems · doi:10.1007/s10916-010-9531-y · Cited by 50 · see citing works
Chemla, D., Nitenberg, A., Teboul, J., Richard, C., Monnet, X., Clésiau, H. L., Valensi, P. E., & Brahimi, M. (2008) · Clinical and Experimental Pharmacology and Physiology · doi:10.1111/j.1440-1681.2008.04927.x · Cited by 47 · see citing works
Effect of cold, isometric exercise, and combination of both on aortic pulse in healthy subjects
Geleris, P., Stavrati, A., & Boudoulas, H. K. (2004) · The American Journal of Cardiology · doi:10.1016/j.amjcard.2003.09.059 · Cited by 47 · see citing works
Self-citationNürnberger, J. (2003) · Clinical Pharmacology & Therapeutics · doi:10.1016/s0009-9236(03)00087-0 · Cited by 44 · see citing works
Bhattacharya, S., Nikbakht, M., Alden, A., Tan, P., Wang, J., Alhalimi, T. A., Kim, S., Wang, P., Tanaka, H., Tandon, A., et al. (2023) · Advanced Electronic Materials · doi:10.1002/aelm.202201284 · Cited by 42 · see citing works
Parrott, C. W., Burnham, K. M., Quale, C., et al. (2004) · Congestive Heart Failure · doi:10.1111/j.1527-5299.2004.03407.x · Cited by 41 · see citing works
OORT, A. V., Hopman, J. C. W., de Boo, T., et al. (1994) · Pediatric Cardiology · doi:10.1007/bf00798120 · Cited by 38 · see citing works
Burwash, I. G., Otto, C. M., & Pearlman, A. S. (1993) · The American Journal of Cardiology · doi:10.1016/0002-9149(93)90313-2 · Cited by 34 · see citing works
Sztrymf, B., Günther, S., Artaud-Macari, É., Savale, L., Jaïs, X., Sitbon, O., Simonneau, G., Humbert, M. J. C., & Chemla, D. (2013) · CHEST Journal · doi:10.1378/chest.12-2659 · Cited by 30 · see citing works
Noninvasive cardiac monitoring in pregnancy: impedance cardiography versus echocardiography
Burlingame, J. M., Ohana, P., Aaronoff, M., et al. (2013) · Journal of Perinatology · doi:10.1038/jp.2013.35 · Cited by 31 · see citing works
Chemla, D., Nitenberg, A., Teboul, J., Richard, C., Monnet, X., Clésiau, H. L., Valensi, P. E., & Brahimi, M. (2008) · Clinical and Experimental Pharmacology and Physiology · doi:10.1111/j.1440-1681.2008.05084.x · Cited by 31 · see citing works
Szymański, P., Rezler, J., Stec, S. M., et al. (2002) · Clinical Cardiology · doi:10.1002/clc.4950250807 · Cited by 29 · see citing works
Naseri, A., Şen, İ., Turgut, K., et al. (2019) · Research in Veterinary Science · doi:10.1016/j.rvsc.2019.08.009 · Cited by 28 · see citing works
Systolic Time Interval Estimation Using Continuous Wave Radar With On-Body Antennas
Buxi, D., Hermeling, E., Mercuri, M., Beutel, F., van der Westen, R. G., Torfs, T., Redouté, J., & Yuce, M. R. (2017) · IEEE Journal of Biomedical and Health Informatics · doi:10.1109/jbhi.2017.2731790 · Cited by 26 · see citing works
Mitchell, A., Bührmann, S., Saez, A. M. O., Rushentsova, U., Schäfers, R. F., Philipp, T., & Nürnberger, J. (2005) · Cardiovascular Drugs and Therapy · doi:10.1007/s10557-005-6890-6 · Cited by 25 · see citing works
Gueugniaud, P., Muchada, R. A., Moussa, M., et al. (1997) · Canadian Journal of Anesthesia/Journal canadien d anesthésie · doi:10.1007/bf03013390 · Cited by 26 · see citing works
The effect of fundal pressure at Caesarean section on maternal haemodynamics
Kim, T., & Ryu, D. H. (2006) · Anaesthesia · doi:10.1111/j.1365-2044.2006.04612.x · Cited by 20 · see citing works
Cotter, P. A., Han, A. J., Everson, J. J., et al. (2008) · Journal of Experimental Zoology Part A Ecological Genetics and Physiology · doi:10.1002/jez.453 · Cited by 20 · see citing works
“We regressed HR-corrected (c) values of cDSA, cDAV, cDVB, cQS2, cS1S2, cPEP/ DVB (HR-corrected PEP/HR-corrected DVB), and cQT against RVM. Validation of hemodynamic measurements and patterns Because our study focused on general hemodynamic patterns and comparative effects of maturation state and heart size on cardiac…”
BackgroundMethodInfluentialAdvFPCG-Delineator: Advanced delineator for fetal phonocardiography
Tomassini, S., Sbrollini, A., Strazza, A., Sameni, R., Marcantoni, I., Morettini, M., & Burattini, L. (2020) · Biomedical Signal Processing and Control · doi:10.1016/j.bspc.2020.102021 · Cited by 16 · see citing works
Hirahara, I., Umeyama, K., Shofuda, K., et al. (2002) · Nephrology · doi:10.1046/j.1440-1797.2002.0085b.x · Cited by 17 · see citing works
Farinatti, P., Monteiro, W., Oliveira, R. B., & Crisafulli, A. (2017) · Aging Clinical and Experimental Research · doi:10.1007/s40520-017-0776-x · Cited by 16 · see citing works
Ventura, H. O., Pranulis, M. F., Young, C. B. A., et al. (2000) · Congestive Heart Failure · doi:10.1111/j.1527-5299.2000.80147.x · Cited by 16 · see citing works
Measurements of systolic time intervals using a transoesophageal pulsed echo-Doppler
Tournadre, J.-P., Muchada, R. A., Lansiaux, S., & CHASSARD, D. (1999) · British Journal of Anaesthesia · doi:10.1093/bja/83.4.630 · Cited by 16 · see citing works
Combining Multiple Psychophysiological Measures of Listening Effort: Challenges and Recommendations
Richter, M., Buhiyan, T., Bramsløw, L., Innes-Brown, H., Fiedler, L., Hadley, L. V., Naylor, G., Saunders, G., Wendt, D., Whitmer, W., et al. (2023) · Seminars in Hearing · doi:10.1055/s-0043-1767669 · Cited by 15 · see citing works
Obesity and the Role of Short Duration Submaximal Work on Cardiovascular and Cerebral Hemodynamics
Cavuoto, L. A., & Maikala, R. V. (2016) · PLoS ONE · doi:10.1371/journal.pone.0153826 · Cited by 14 · see citing works
Rabow, S., Jonsson, H., Bro, E., & Olofsson, P. (2023) · The Journal of Maternal-Fetal & Neonatal Medicine · doi:10.1080/14767058.2023.2208252 · Cited by 14 · see citing works
Peverill, R. E., Chou, B., & Donelan, L. (2017) · PLoS ONE · doi:10.1371/journal.pone.0173383 · Cited by 13 · see citing works
Khandoker, A. H., Marzbanrad, F., Kimura, Y., et al. (2016) · doi:10.1109/embc.2016.7591544 · Cited by 13 · see citing works
“During the diastolic period, Isovolumic Relaxation Time (IRT) occurs from Ac to mitral opening (Mo) time and is followed by Ventricular Filling Time (VFT) from opening to closing time of mitral [9].”
BackgroundChemla, D., Aptecar, E., Hébert, J., et al. (2000) · American Journal of Physiology-Heart and Circulatory Physiology · doi:10.1152/ajpheart.2000.279.1.h122 · Cited by 13 · see citing works
“Given that increased preload tends to prolong ejection duration (5, 8, 23, 38), one might expect blood pressure variability in HTR to be related to beat-to-beat LVET via a common hemodynamic mechanism, namely, the respiratory-related changes in preload.”
BackgroundInfluentialvan Houte, J., Eerdekens, R., Manning, F., et al. (2024) · Ultrasound in Medicine & Biology · doi:10.1016/j.ultrasmedbio.2023.12.013 · Cited by 11 · see citing works
Hole, T., & Skjærpe, T. (2003) · Echocardiography · doi:10.1046/j.1540-8175.2003.00001.x · Cited by 11 · see citing works
Alhakak, A. S., Olsen, F. J., Skaarup, K. G., et al. (2023) · Clinical Research in Cardiology · doi:10.1007/s00392-023-02269-2 · Cited by 10 · see citing works
Haghebaert, M., Varsos, P., Meiburg, R., & Vignon-Clementel, I. E. (2025) · The Journal of Physiology · doi:10.1113/jp287929 · Cited by 9 · see citing works
Javaid, A. Q., Dowling, S., Etemadi, M., Heller, J. A., Roy, S., Klein, L., & Inan, O. T. (2016) · Computing in cardiology · doi:10.22489/cinc.2016.224-428 · Cited by 11 · see citing works
Nacif, M. S., de Almeida, A. L. C., Young, A. A., Cowan, B. R., Armstrong, A. D. C., Yang, E., Sibley, C. T., Hundley, W. G., Liu, S., Lima, J. A. C., et al. (2017) · Arquivos Brasileiros de Cardiologia · doi:10.5935/abc.20170063 · Cited by 10 · see citing works
Oumeiri, B. E., Entee, K. M., Annoni, F., Herpain, A., Eynden, F. V., Jespers, P., Nooten, G. V., & van de Borne, P. (2018) · BMC Cardiovascular Disorders · doi:10.1186/s12872-018-0831-3 · Cited by 8 · see citing works
AI-Based Estimation of End-Systolic Elastance From Arm-Pressure and Systolic Time Intervals
Bikia, V., Adamopoulos, D. N., Pagoulatou, S., Rovas, G., & Stergiopulos, N. (2021) · Frontiers in Artificial Intelligence · doi:10.3389/frai.2021.579541 · Cited by 8 · see citing works
“Systolic time intervals can be easily and precisely measured in the clinical practice and may be used for detecting alterations in LV systolic function (Boudoulas, 1990).”
BackgroundMethodInfluentialThe Antihypertensive and Cardiac Hemodynamic Effects of Nebivolol
DECREE, J., Rooy, P. V., Geukens, H., et al. (1992) · Angiology · doi:10.1177/000331979204300501 · Cited by 9 · see citing works
Tigges, T., Feldheiser, A., Pielmuş, A., et al. (2019) · doi:10.1109/embc.2019.8856652 · Cited by 8 · see citing works
“As PEP is directly associated with the amount of cardiac preload [6] and consequently also SV, PAT measurements might serve as a suitable parameter to reflect changes in SV during hypovolemia.”
BackgroundZakeri, V., Tavakolian, K., Blaber, A. P., Bauer, E. P., Dehkordi, P., & Khosrow-Khavar, F. (2020) · Physiological Measurement · doi:10.1088/1361-6579/ab6f53 · Cited by 8 · see citing works
Nürnberger, J., Dammer, S., Philipp, T., Wenzel, R. R., & Schäfers, R. F. (2003) · Cardiovascular Diabetology · doi:10.1186/1475-2840-2-7 · Cited by 8 · see citing works
Lee, W.-H., Hsu, P., Chu, C., et al. (2016) · Scientific Reports · doi:10.1038/srep29293 · Cited by 7 · see citing works
Noninvasive Cardiac Haemodynamics of Nebivolol
Crée, J. D., Geukens, H., & Verhaegen, H. (1991) · Clinical Drug Investigation · doi:10.1007/bf03258262 · Cited by 7 · see citing works
Arterial Stiffness and the Sympathetic Nervous System
Parati, G., & Salvi, P. (2014) · Springer eBooks · doi:10.1007/978-1-4471-5198-2_14 · Cited by 6 · see citing works
Luciani, M., Saccocci, M., Kuwata, S., et al. (2019) · Frontiers in Physiology · doi:10.3389/fphys.2019.01090 · Cited by 6 · see citing works
“%) is due to diminished rate of increase in LV pressure in isolvolumic contraction (Boudoulas, 1990).”
BackgroundResultInfluentialSystolic duration, preload, and afterload: is a new paradigm needed?
Chemla, D., & Nitenberg, A. (2006) · Intensive Care Medicine · doi:10.1007/s00134-006-0279-2 · Cited by 6 · see citing works
“a minor role [5], and it is explainable thanks to basic principles of cardiac”
BackgroundAdaptive Left Ventricular Ejection Time Estimation Using Multiple Peripheral Pressure Waveforms
Hahn, J., McCombie, D. B., Asada, H. H., et al. (2005) · doi:10.1109/iembs.2005.1616946 · Cited by 6 · see citing works
“LVET is a function of ventricular contractility, and has been used extensively in pharmacology and physiology research [1,2].”
MethodInvestigating fetal myocardial function in heart anomalies by Doppler myocardial performance indices
Khandoker, A. H., Al-Angari, H. M., Marzbanrad, F., et al. (2017) · doi:10.1109/embc.2017.8037290 · Cited by 6 · see citing works
van Houte, J., de Boer, E. C., Manning, F., et al. (2024) · JCA advances. · doi:10.1016/j.jcadva.2024.100023 · Cited by 5 · see citing works
Time and left ventricular function: the forgotten dynamic factor
Boudoulas, K. D., & Boudoulas, H. K. (2021) · European Journal of Heart Failure · doi:10.1002/ejhf.2165 · Cited by 5 · see citing works
Self-citationNon-invasive aortic blood flow measurement
ORLIAGUET, G. A., & Gueugniaud, P. Y. (2000) · Current Opinion in Anaesthesiology · doi:10.1097/00001503-200006000-00013 · Cited by 5 · see citing works
Vettorello, M., Santambrogio, S., Calini, A., et al. (2013) · Acta Anaesthesiologica Scandinavica · doi:10.1111/aas.12135 · Cited by 5 · see citing works
Left ventricular output indices in hospitalized heart failure: when “simpler” may not mean “better”
Mele, D., Pestelli, G., Smarrazzo, V., Molin, D. D., Luisi, G. A., Trevisan, F., Fiorencis, A., & Ferrari, R. (2020) · International journal of cardiac imaging · doi:10.1007/s10554-020-01946-x · Cited by 5 · see citing works
Camera Seismocardiogram Based Monitoring of Left Ventricular Ejection Time
Zhou, Z., Huang, J., Li, H., et al. (2025) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2025.3548090 · Cited by 4 · see citing works
Regional myocardial function in healthy adults: assessment through tissue Doppler echocardiography
Cardim, N. M., Oliveira, A. G., Longo, S., Ferreira, T. C., Pereira, A., dos Reis, R. P., & Correia, J. M. (2003) · Arquivos Brasileiros de Cardiologia · doi:10.1590/s0066-782x2003000500001 · Cited by 4 · see citing works
Dehkordi, P., Tavakolian, K., Zhao, T., et al. (2019) · Computing in cardiology · doi:10.22489/cinc.2019.328 · Cited by 4 · see citing works
Middel, C., Stetzuhn, M., Sander, N., et al. (2023) · Intensive Care Medicine Experimental · doi:10.1186/s40635-023-00543-1 · Cited by 4 · see citing works
“The systolic time ratio is a sensitive cardiovascular marker, an increased ratio correlates with a reduced left ventricular ejection fraction [17, 18].”
BackgroundRajanathan, R., Pedersen, T. M., Guldbrandsen, H. O., et al. (2023) · Biomedicines · doi:10.3390/biomedicines11020344 · Cited by 4 · see citing works
Myocardial effects of isoflurane in healthy infants and small children
Gueugniaud, D. P. Y., Bertin-Maghit, M., Abisseror, M., et al. (1998) · Acta Anaesthesiologica Scandinavica · doi:10.1111/j.1399-6576.1998.tb05118.x · Cited by 4 · see citing works
Khandoker, A. H., Al-Angari, H. M., Marzbanrad, F., & Kimura, Y. (2021) · Current Research in Physiology · doi:10.1016/j.crphys.2021.02.002 · Cited by 3 · see citing works
“Because fetal circulation is ventricle-dominant connecting placenta (Friedman et al., 2003; Boudoulas, 1990) ventricular filling time (VFT) was proposed to be included in estimating fetal myocardial index.”
BackgroundContinuous Venous-Arterial Doppler Ultrasound During a Preload Challenge
Kenny, J. S., Gibbs, S. O., Johnston, D., Hofer, L. M., Rae, E., Clarke, G., Eibl, J. K., Nalla, B. P., & Atoui, R. (2023) · Journal of Visualized Experiments · doi:10.3791/64410 · Cited by 3 · see citing works
Fazio, R. D., Cascella, I., Yalçınkaya, Ş. E., et al. (2025) · Sensors · doi:10.3390/s25134220 · Cited by 3 · see citing works
“Some studies have shown that in HFrEF patients, the LVET decreases while the PEP increases, compared to healthy individuals [36].”
Dehkordi, P., Tavakolian, K., Zhao, T., Zakeri, V., & Khosrow-Khavar, F. (2019) · doi:10.23919/cinc49843.2019.9005826 · Cited by 3 · see citing works
Relation between left ventricular ejection time and pulmonary hemodynamics in pulmonary hypertension
Günther, S., Sztrymf, B., Savale, L., et al. (2015) · International Journal of Cardiology · doi:10.1016/j.ijcard.2015.02.101 · Cited by 3 · see citing works
“Heart ratecorrected time intervals were calculated by using the Weissler and the Bazett formulas [8].”
BackgroundMethodCybulski, G., Niewiadomski, W., Strasz, A., et al. (2009) · Journal of Human Kinetics · doi:10.2478/v10078-09-0007-4 · Cited by 2 · see citing works
Taimela, E., Koskinen, P. J., Nuutila, P., et al. (1995) · Scandinavian Journal of Clinical and Laboratory Investigation · doi:10.3109/00365519509089611 · Cited by 2 · see citing works
Corradi, F., Santori, G., Brusasco, C., Robba, C., Wong, A. V.-K., Nicolò, P. D., Tecchi, L., Dazzi, F., Taddei, E., Isirdi, A., et al. (2023) · Journal of Clinical Medicine · doi:10.3390/jcm12020700 · Cited by 2 · see citing works
Automatic Detection of Low-Quality Seismocardiogram Cycles Using the Outlier Approach
Zakeri, V., Khosrow-Khavar, F., & Tavakolian, K. (2015) · World Congress on Medical Physics and Biomedical Engineering, September 7 - 12, 2009, Munich, Germany · doi:10.1007/978-3-319-19387-8_247 · Cited by 1 · see citing works
Karmakar, C. K., Imam, H., Li, P., et al. (2015) · Computing in cardiology · doi:10.1109/cic.2015.7408665 · Cited by 1 · see citing works
Pharmacodynamic Evaluation: Cardiovascular Methodologies
de Mey, C., & Hinder, M. (2010) · Springer eBooks · doi:10.1007/978-3-540-89891-7_31 · Cited by 1 · see citing works
Les intervalles de temps systoliques en réanimation
Bendjelid, K. (2007) · Réanimation · doi:10.1016/j.reaurg.2007.02.007 · Cited by 1 · see citing works
Manejo hemodinámico intraoperatorio del quemado con falla multiorgánica
Barreiro, G., Cambrún, G., Zunini, G., et al. (2000) · Anestesia Analgesia Reanimación
Beta bloqueantes durante la anestesia general. Esmolol para prevención de la isquemia miocárdica.
Muchada, R. A. (2001) · Redalyc (Universidad Autónoma del Estado de México)
Beta Blockers and General Anesthesia: Prevention of Myocardial Ischemia
Muchada, R. A. (2000) · Springer eBooks · doi:10.1007/978-88-470-2286-7_35
Tükek, T., Yıldız, A., Akkaya, V., et al. (2002) · Nephrology · doi:10.1111/j.1440-1797.2006.00754.x-i1
Preload Dependency Dynamic Indices
Giraud, R., & Bendjelid, K. (2016) · Springer eBooks · doi:10.1007/978-3-319-29430-8_6
Should Beta-Blockers Have a Place in the Treatment of Septic Shock?
Muchada, R. A. (1998) · Springer eBooks · doi:10.1007/978-88-470-2278-2_4
Moon, Y., Lee, H.-M., Kim, J.-W., Chung, H.-J., Lee, S., Huh, I. Y., & Hwang, G. (2015) · Anesthesia and Pain Medicine · doi:10.17085/apm.2015.10.3.208
Kumai, K., Tomiyama, H., Takahashi, T., Nakano, H., Fujii, M., Iwasaki, Y., Matsumoto, C., Shiina, K., Yamashina, A., & Chikamori, T. (2021) · Journal of Atherosclerosis and Thrombosis · doi:10.5551/jat.63099
Cardiovascular Psychophysiology and Antisocial Behavior
McGarry, P., & Portnoy, J. (2022) · Springer eBooks · doi:10.1007/978-3-030-80882-2_3
Seetharam, S. P., Shankar, M. S. V., & Reddy, N. (2022) · Journal of the Practice of Cardiovascular Sciences · doi:10.4103/jpcs.jpcs_17_22
Ventricular Function and Cardio-Ankle Vascular Index in Patients With Pulmonary Artery Hypertension
Radchenko, G., Botsiuk, Y. A., & Sirenko, Y. (2022) · Vascular Health and Risk Management · doi:10.2147/vhrm.s385536
- Authors
- Boudoulas, H.
- Affiliations
- The Ohio State University (US)
- Corresponding author
- Boudoulas, H.
- Venue
- European Heart Journal
- Publisher
- Oxford University Press (OUP)
- Published
- 1990-01-02
- Volume
- 11
- Issue
- suppl I
- Pages
- 93-104
- ISSN
- 0195-668X (ISSN-L)
- 1522-9645
- OpenAlex
- W2085407295
- Cited by
- 110
- References
- 0
- Citations by year
- 2026: 3 · 2025: 3 · 2024: 7 · 2023: 9 · 2022: 3 · 2021: 6 · 2020: 3 · 2019: 6 · 2018: 2 · 2017: 6 · 2016: 8 · 2015: 4 · 2014: 1 · 2013: 4
- FWCI
- 1.19
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- European Heart Journal (publishedVersion)
- PubMed (publishedVersion)
- Topics
- Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Cardiovascular Function and Risk Factors
- Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Cardiovascular Health and Disease Prevention
- Health Sciences › Medicine › Surgery › Hemodynamic Monitoring and Therapy
- Keywords
- systolic time intervals, cardiac cycle, left ventricular function, ventricular function, cardiac hemodynamics
- MeSH terms
- Cardiac Output, Cardiovascular Diseases, Echocardiography, Electrocardiography, Humans, Myocardial Contraction, Stroke Volume, Systole, Echocardiography, Doppler, Ventricular Function, Left
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review